2,848 research outputs found
A new photon recoil experiment: towards a determination of the fine structure constant
We report on progress towards a measurement of the fine structure constant to
an accuracy of or better by measuring the ratio of the
Planck constant to the mass of the cesium atom. Compared to similar
experiments, ours is improved in three significant ways: (i) simultaneous
conjugate interferometers, (ii) multi-photon Bragg diffraction between same
internal states, and (iii) an about 1000 fold reduction of laser phase noise to
-138 dBc/Hz. Combining that with a new method to simultaneously stabilize the
phases of four frequencies, we achieve 0.2 mrad effective phase noise at the
location of the atoms. In addition, we use active stabilization to suppress
systematic effects due to beam misalignment.Comment: 12 pages, 9 figure
Design and Implementation of a Stepped Frequency Continuous Wave Radar System for Biomedical Applications
There is a need to detect vital signs of human (e.g., the respiration and heart-beat rate) with noncontact method in a number of applications such as search and rescue operation (e.g. earthquakes, fire), health monitoring of the elderly, performance monitoring of athletes Ultra-wideband radar system can be utilized for noncontact vital signs monitoring and tracking of various human activities of more than one subject. Therefore, a stepped-frequency continuous wave radar (SFCW) system with wideband performance is designed and implemented for Vital signs detection and fall events monitoring. The design of the SFCW radar system is firstly developed using off-the-shelf discrete components. Later, the system is implemented using surface mount components to make it portable with low cost. The measurement result is proved to be accurate for both heart rate and respiration rate detection within ±5% when compared with contact measurements. Furthermore, an electromagnetic model has been developed using a multi-layer dielectric model of the human subject to validate the experimental results. The agreement between measured and simulated results is good for distances up to 2 m and at various subjects’ orientations with respect to the radar, even in the presence of more than one subject. The compressive sensing (CS) technique is utilized to reduce the size of the acquired data to levels significantly below the Nyquist threshold. In our demonstration, we use phase information contained in the obtained complex high-resolution range profile (HRRP) to derive the motion characteristics of the human. The obtained data has been successfully utilized for non-contact walk, fall and limping detection and healthcare monitoring. The effectiveness of the proposed method is validated using measured results
Phase Noise Analyses and Measurements in the Hybrid Memristor-CMOS Phase-Locked Loop Design and Devices Beyond Bulk CMOS
Phase-locked loop (PLLs) has been widely used in analog or mixed-signal integrated circuits. Since there is an increasing market for low noise and high speed devices, PLLs are being employed in communications. In this dissertation, we investigated phase noise, tuning range, jitter, and power performances in different architectures of PLL designs. More energy efficient devices such as memristor, graphene, transition metal di-chalcogenide (TMDC) materials and their respective transistors are introduced in the design phase-locked loop.
Subsequently, we modeled phase noise of a CMOS phase-locked loop from the superposition of noises from its building blocks which comprises of a voltage-controlled oscillator, loop filter, frequency divider, phase-frequency detector, and the auxiliary input reference clock. Similarly, a linear time-invariant model that has additive noise sources in frequency domain is used to analyze the phase noise. The modeled phase noise results are further compared with the corresponding phase-locked loop designs in different n-well CMOS processes.
With the scaling of CMOS technology and the increase of the electrical field, the problem of short channel effects (SCE) has become dominant, which causes decay in subthreshold slope (SS) and positive and negative shifts in the threshold voltages of nMOS and pMOS transistors, respectively. Various devices are proposed to continue extending Moore\u27s law and the roadmap in semiconductor industry. We employed tunnel field effect transistor owing to its better performance in terms of SS, leakage current, power consumption etc. Applying an appropriate bias voltage to the gate-source region of TFET causes the valence band to align with the conduction band and injecting the charge carriers. Similarly, under reverse bias, the two bands are misaligned and there is no injection of carriers. We implemented graphene TFET and MoS2 in PLL design and the results show improvements in phase noise, jitter, tuning range, and frequency of operation. In addition, the power consumption is greatly reduced due to the low supply voltage of tunnel field effect transistor
Recommended from our members
High-Speed Data Acquisition System for Nanoscale Imaging
This technical report is the product of a senior design project in the Department of Electrical and
Computer Engineering at the University of Texas at Austin and was written in conformance with
the ECE senior design final report requirements. Current scanning probe microscopy systems are
often limited by the speed and resultion at which they sample. In this technical report, we
demonstrate a novel data acquisition, processing, and visualization system that leverages
machine learning to collect and analyze data from an extant scanning probe microscope at 4
MS/s. The system comprises four subsystems: a current preamplifier, a data acquisition system, a
data processing and visualization module, and an interactive graphic user interface. The current
preamplifier amplifies small currents on the order of nanoamps to voltages readable by the data
acquisition system. The data acquisition system takes in input data from the scanning probe
microscope and stores them into usable file formats for the data processing module. The data
processing module uses various software signal processing techniques to analyze and visualize
the data. Finally, the graphic user interface acts as the main user control system, initiating data
collection and viewing collected data on user command. Future work on this system includes
system-wide testing as well as optimizing the robustness of each subsystem to meet the
constraints of the scanning probe microscope system.Electrical and Computer Engineerin
High Speed CMOS VCO For Advanced Communications [TK7871.99.M99 C435 2003 f rb][Microfiche 7271].
Peningkatan keperluan bagi komunikasi tanpa wayar dalam suara dan data telah memotivasikan kerja-kerja untuk meningkatkan tahap intregrasi dalam pemancar-penerima berfrekuensi radio (RF) baru-baru ini.
The fast growing demand of wireless communications for voice and data has driven recent efforts to dramatically increase the level of integration in RF transceivers
A Low-Power Silicon-Photomultiplier Readout ASIC for the CALICE Analog Hadronic Calorimeter
The future e + e − collider experiments, such as the international linear collider, provide precise measurements of the heavy bosons and serve as excellent tests of the underlying fundamental physics. To reconstruct these bosons with an unprecedented resolution from their multi-jet final states, a detector system employing the particle flow approach has been proposed, requesting calorimeters with imaging capabilities. The analog hadron calorimeter based on the SiPM-on-tile technology is one of the highly granular candidates of the imaging calorimeters.
To achieve the compactness, the silicon-photomultiplier (SiPM) readout electronics require a low-power monolithic solution.
This thesis presents the design of such an application-specific integrated circuit (ASIC) for the charge and timing readout of the SiPMs. The ASIC provides precise charge measurement over a large dynamic range with auto-triggering and local zero-suppression functionalities. The
charge and timing information are digitized using channel-wise analog-to-digital and time-to-digital converters, providing a fully integrated solution for the SiPM readout. Dedicated to the analog hadron calorimeter, the power-pulsing technique is applied to the full chip to
meet the stringent power consumption requirement.
This work also initializes the commissioning of the calorimeter layer with the use of the designed ASIC. An automatic calibration procedure has been developed to optimized the configuration settings for the chip. The new calorimeter base unit with the designed ASIC has been produced and its functionality has been tested
- …