13,424 research outputs found
Recommended from our members
Evaluation of the Linear Relationship Between Pulse Arrival Time and Blood Pressure in ICU Patients: Potential and Limitations
A variety of techniques based on the indirect measurement of blood pressure (BP) by Pulse Transit Time (PTT) have been explored over the past few years. Such an approach has the potential in providing continuous and non-invasive beat to beat blood pressure without the use of a cuff. Pulse Arrival Time (PAT) which includes the cardiac pre-ejection period has been proposed as a surrogate of PTT, however, the balance between its questioned accuracy and measurement simplicity has yet to be established. The present work assessed the degree of linear relationship between PAT and blood pressure on 96 h of continuous electrocardiography and invasive radial blood pressure waveforms in a group of 11 young ICU patients. Participants were selected according to strict exclusion criteria including no use of vasoactive medications and presence of clinical conditions associated with cardiovascular diseases. The average range of variation for diastolic BP was 60 to 79 mmHg while systolic BP varied between 123 and 158 mmHg in the study database. The overall Pearson correlation coefficient for systolic and diastolic blood pressure was −0.5 and −0.42, respectively, while the mean absolute error was 3.9 and 7.6 mmHg. It was concluded that the utilization of PAT for the continuous non-invasive blood pressure estimation is rather limited according to the experimental setup, nonetheless the correlation coefficient performed better when the range of variation of blood pressure was high over periods of 30 min suggesting that PAT has the potential to be used as indicator of changes relating to hypertensive or hypotensive episodes
Recommended from our members
A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure
Hypertension or high blood pressure is a leading cause of death throughout the world and a critical factor for increasing the risk of serious diseases, including cardiovascular diseases such as stroke and heart failure. Blood pressure is a primary vital sign that must be monitored regularly for the early detection, prevention and treatment of cardiovascular diseases. Traditional blood pressure measurement techniques are either invasive or cuff-based, which are impractical, intermittent, and uncomfortable for patients. Over the past few decades, several indirect approaches using photoplethysmogram (PPG) have been investigated, namely, pulse transit time, pulse wave velocity, pulse arrival time and pulse wave analysis, in an effort to utilise PPG for estimating blood pressure. Recent advancements in signal processing techniques, including machine learning and artificial intelligence, have also opened up exciting new horizons for PPG-based cuff less and continuous monitoring of blood pressure. Such a device will have a significant and transformative impact in monitoring patients’ vital signs, especially those at risk of cardiovascular disease. This paper provides a comprehensive review for non-invasive cuff-less blood pressure estimation using the PPG approach along with their challenges and limitations
Investigating properties of the cardiovascular system using innovative analysis algorithms based on ensemble empirical mode decomposition
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited - Copyright @ 2012 Jia-Rong Yeh et al.Cardiovascular system is known to be nonlinear and nonstationary. Traditional linear assessments algorithms of arterial stiffness and systemic resistance of cardiac system accompany the problem of nonstationary or inconvenience in practical applications. In this pilot study, two new assessment methods were developed: the first is ensemble empirical mode decomposition based reflection index (EEMD-RI) while the second is based on the phase shift between ECG and BP on cardiac oscillation. Both methods utilise the EEMD algorithm which is suitable for nonlinear and nonstationary systems. These methods were used to investigate the properties of arterial stiffness and systemic resistance for a pig's cardiovascular system via ECG and blood pressure (BP). This experiment simulated a sequence of continuous changes of blood pressure arising from steady condition to high blood pressure by clamping the artery and an inverse by relaxing the artery. As a hypothesis, the arterial stiffness and systemic resistance should vary with the blood pressure due to clamping and relaxing the artery. The results show statistically significant correlations between BP, EEMD-based RI, and the phase shift between ECG and BP on cardiac oscillation. The two assessments results demonstrate the merits of the EEMD for signal analysis.This work is supported by the National Science Council (NSC) of Taiwan (Grant number NSC 99-2221-E-155-046-MY3), Centre for Dynamical Biomarkers and Translational Medicine, National Central University,
Taiwan which is sponsored by National Science Council (Grant number: NSC 100–2911-I-008-001) and the Chung-Shan Institute of Science & Technology in Taiwan (Grant numbers: CSIST-095-V101 and CSIST-095-V102)
Aging is associated with an earlier arrival of reflected waves without a distal shift in reflection sites
Background-Despite pronounced increases in central pulse wave velocity (PWV) with aging, reflected wave transit time (RWTT), traditionally defined as the timing of the inflection point (T-INF) in the central pressure waveform, does not appreciably decrease, leading to the controversial proposition of a "distal-shift" of reflection sites. T-INF, however, is exceptionally prone to measurement error and is also affected by ejection pattern and not only by wave reflection. We assessed whether RWTT, assessed by advanced pressure-flow analysis, demonstrates the expected decline with aging. Methods and Results-We studied a sample of unselected adults without cardiovascular disease (n=48; median age 48 years) and a clinical population of older adults with suspected/established cardiovascular disease (n=164; 61 years). We measured central pressure and flow with carotid tonometry and phase-contrast MRI, respectively. We assessed RWTT using wave-separation analysis (RWTTWSA) and partially distributed tube-load (TL) modeling (RWTTTL). Consistent with previous reports, T-INF did not appreciably decrease with age despite pronounced increases in PWV in both populations. However, aging was associated with pronounced decreases in RWTTWSA (general population -15.0 ms/decade, P<0.001; clinical population -9.07 ms/decade, P=0.003) and RWTTTL (general -15.8 ms/decade, P<0.001; clinical -11.8 ms/decade, P<0.001). There was no evidence of an increased effective reflecting distance by either method. TINF was shown to reliably represent RWTT only under highly unrealistic assumptions about input impedance. Conclusions-RWTT declines with age in parallel with increased PWV, with earlier effects of wave reflections and without a distal shift in reflecting sites. These findings have important implications for our understanding of the role of wave reflections with aging
Oral magnesium supplementation improves endothelial function and attenuates subclinical atherosclerosis in thiazide-treated hypertensive women
Background: Epidemiological studies demonstrate an inverse association between serum magnesium and incidence of cardiovascular disease. Diuretics commonly cause hypomagneseamia.
Method: We evaluated effects of magnesium supplementation on blood pressure (BP) and vascular function in thiazide-treated hypertensive women in a randomized, double-blind, clinical trial. Hypertensive women (40–65 years) on hydrochlorothiazide and mean 24-h BP at least 130/80 mmHg were divided into placebo and supplementation (magnesium chelate 600 mg/day) groups. Patients were evaluated for nutritional and biochemical parameters, office and ambulatory blood pressure monitoring, brachial flow-mediated dilatation (FMD), peripheral arterial tonometry, assessment of carotid intima–media thickness, central hemodynamic parameters and pulse wave velocity at inclusion and after 6-month follow-up.
Results: The magnesium group had a significant reduction in SBP (144 ± 17 vs. 134 ± 14 mmHg, P = 0.036) and DBP (88 ± 9 vs. 81 ± 8 mmHg, P = 0.005) at 6 months, without effect on plasma glucose, lipids, or arterial stiffness parameters. The placebo group showed a significant increase in carotid intima-media thickness (0.78 ± 0.13 vs. 0.89 ± 0.14 mm, P = 0.033) without change in the magnesium group (0.79 ± 0.16 vs. 0.79 ± 0.19 mm, P = 0.716) after 6 months. The magnesium group demonstrated a significant increase in variation of FMD vs. the placebo group (+3.7 ± 2.1 vs. 2.4 ± 1.2%, P = 0.015). There was a significant correlation between the intracellular magnesium variation and FMD (r = 0.44, P = 0.011).
Conclusion: Magnesium supplementation was associated with better BP control, improved endothelial function and amelioration of subclinical atherosclerosis in these thiazide-treated hypertensive women
Recommended from our members
Monitoring of the central blood pressure waveform via a conformal ultrasonic device.
Continuous monitoring of the central-blood-pressure waveform from deeply embedded vessels, such as the carotid artery and jugular vein, has clinical value for the prediction of all-cause cardiovascular mortality. However, existing non-invasive approaches, including photoplethysmography and tonometry, only enable access to the superficial peripheral vasculature. Although current ultrasonic technologies allow non-invasive deep-tissue observation, unstable coupling with the tissue surface resulting from the bulkiness and rigidity of conventional ultrasound probes introduces usability constraints. Here, we describe the design and operation of an ultrasonic device that is conformal to the skin and capable of capturing blood-pressure waveforms at deeply embedded arterial and venous sites. The wearable device is ultrathin (240 μm) and stretchable (with strains up to 60%), and enables the non-invasive, continuous and accurate monitoring of cardiovascular events from multiple body locations, which should facilitate its use in a variety of clinical environments
Estimating Blood Pressure from Photoplethysmogram Signal and Demographic Features using Machine Learning Techniques
Hypertension is a potentially unsafe health ailment, which can be indicated
directly from the Blood pressure (BP). Hypertension always leads to other
health complications. Continuous monitoring of BP is very important; however,
cuff-based BP measurements are discrete and uncomfortable to the user. To
address this need, a cuff-less, continuous and a non-invasive BP measurement
system is proposed using Photoplethysmogram (PPG) signal and demographic
features using machine learning (ML) algorithms. PPG signals were acquired from
219 subjects, which undergo pre-processing and feature extraction steps. Time,
frequency and time-frequency domain features were extracted from the PPG and
their derivative signals. Feature selection techniques were used to reduce the
computational complexity and to decrease the chance of over-fitting the ML
algorithms. The features were then used to train and evaluate ML algorithms.
The best regression models were selected for Systolic BP (SBP) and Diastolic BP
(DBP) estimation individually. Gaussian Process Regression (GPR) along with
ReliefF feature selection algorithm outperforms other algorithms in estimating
SBP and DBP with a root-mean-square error (RMSE) of 6.74 and 3.59 respectively.
This ML model can be implemented in hardware systems to continuously monitor BP
and avoid any critical health conditions due to sudden changes.Comment: Accepted for publication in Sensor, 14 Figures, 14 Table
Cardiovascular features of possible autonomous cortisol secretion in patients with adrenal incidentalomas
Background: Low-grade incomplete post-dexamethasone cortisol suppression in patients with adrenal incidentalomas – recently defined as possible autonomous cortisol secretion (pACS) – has been associated with increased cardiovascular events and mortality. However, prospective studies documenting cardiac abnormalities in these patients are lacking. Subjects and methods: Between July 2016 and September 2017, 71 consecutive patients with adrenal lesions were prospectively screened for hypercortisolism by dexamethasone suppression test (NCT 02611258). Complete anthropometric, metabolic and hormonal parameters were recorded along with full cardiac ultrasound assessment and noninvasive measurement of arterial stiffness. All patients underwent chemical-shift magnetic resonance imaging to characterize the lesions. Cardiovascular outcomes were recorded in blind. Results: According to post-dexamethasone suppression cortisol values (post-DST), 34 patients had pACS and 37 nonfunctioning adenomas (NFA). The two groups were similar in sex, BMI, age distribution, cardiovascular risk factors and comorbidities. Left ventricular mass index (LVMIBSA) was increased in pACS compared to NFA (P=0.006) and mildly correlated to the post-DST cortisol level (rho=0.347; P=0.004). The post-DST cortisol levels explained up to 13.7% of LVMIBSAvariance (P=0.002). Compared to NFA, patients with pACS had a higher prevalence of diastolic dysfunction (35.1% vs 82.6%; P=0.001) and worse arterial stiffness assessed by pulse wave velocity (P=0.033). Conclusions: In apparently asymptomatic patients, mild autonomous cortisol secretion can sustain early cardiac and vascular remodeling, independently of other risk factors. The morphological and functional cardiovascular changes observed in pACS underline the need for further studies to correctly define the long-term management of this relatively common condition
- …