49,516 research outputs found

    A Deep Learning Approach for Fusing Sensor Data from Screw Compressors

    Get PDF
    [EN] Chillers are commonly used for thermal regulation to maintain indoor comfort in medium and large buildings. However, inefficiencies in this process produce significant losses, and optimization tasks are limited because of accessibility to the system. Data analysis techniques transform measurements coming from several sensors into useful information. Recent deep learning approaches have achieved excellent results in many applications. These techniques can be used for computing new data representations that provide comprehensive information from the device. This allows real-time monitoring, where information can be checked with current working operation to detect any type of anomaly in the process. In this work, a model based on a 1D convolutional neural network is proposed for fusing data in order to predict four different control stages of a screw compressor in a chiller. The evaluation of the method was performed using real data from a chiller in a hospital building. Results show a satisfactory performance and acceptable training time in comparison with other recent methods. In addition, the model is capable of predicting control states of other screw compressors different than the one used in the training. Furthermore, two failure cases are simulated, providing an early alarm detection when a continuous wrong classification is performed by the model.SIThis research was funded by the Spanish Ministry of Science and Innovation and the European Regional Development Fund under project DPI2015-69891-C2-1-R/2-R.Ministerio de Economía y Competitivida

    A Review on Energy Consumption Optimization Techniques in IoT Based Smart Building Environments

    Get PDF
    In recent years, due to the unnecessary wastage of electrical energy in residential buildings, the requirement of energy optimization and user comfort has gained vital importance. In the literature, various techniques have been proposed addressing the energy optimization problem. The goal of each technique was to maintain a balance between user comfort and energy requirements such that the user can achieve the desired comfort level with the minimum amount of energy consumption. Researchers have addressed the issue with the help of different optimization algorithms and variations in the parameters to reduce energy consumption. To the best of our knowledge, this problem is not solved yet due to its challenging nature. The gap in the literature is due to the advancements in the technology and drawbacks of the optimization algorithms and the introduction of different new optimization algorithms. Further, many newly proposed optimization algorithms which have produced better accuracy on the benchmark instances but have not been applied yet for the optimization of energy consumption in smart homes. In this paper, we have carried out a detailed literature review of the techniques used for the optimization of energy consumption and scheduling in smart homes. The detailed discussion has been carried out on different factors contributing towards thermal comfort, visual comfort, and air quality comfort. We have also reviewed the fog and edge computing techniques used in smart homes

    Cost-effective analysis for selecting energy efficiency measures for refurbishment of residential buildings in Catalonia

    Get PDF
    © 2016. This version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/This paper presents the results of a detailed method for developing cost-optimal studies for the energy refurbishment of residential buildings. The method takes part of an innovative approach: two-step evaluation considering thermal comfort, energy and economic criteria. The first step, the passive evaluation, was presented previously [1] and the results are used to develop the active evaluation, which is the focus of this paper. The active evaluation develops a cost-optimal analysis to compare a set of passive and active measures for the refurbishment of residential buildings. The cost-optimal methodology follows the European Directives and analysed the measures from the point of view of non-renewable primary energy consumption and the global costs over 30 years. The energy uses included in the study are heating, domestic hot water, cooling, lighting and appliances. In addition, the results have been represented following the energy labelling scale. The paper shows the results of a multi-family building built in the years 1990–2007 and located in Barcelona with two configurations: with natural ventilation and without natural ventilation. The method provides technical and economic information about the energy efficiency measures, with the objective to support the decision process.Postprint (author's final draft

    Subzone control method of stratum ventilation for thermal comfort improvement

    Get PDF
    The conventional control method of a collective ventilation (e.g., stratum ventilation) controls the averaged thermal environment in the occupied zone to satisfy the averaged thermal preference of a group of occupants. However, the averaged thermal environment in the occupied zone is not the same as the microclimates of the occupants, because the thermal environment in the occupied zone is not absolutely uniform. Moreover, the averaged thermal preference of the occupants could deviate from the individual thermal preferences, because the occupants could have different individual thermal preferences. This study proposes a subzone control method for stratum ventilation to improve thermal comfort. The proposed method divides the occupied zone into subzones, and controls the microclimates of the subzones to satisfy the thermal preferences of the respective subzones. Experiments in a stratum-ventilated classroom are conducted to model and validate the Predicted Mean Votes (PMVs) of the subzones, with a mean absolute error between 0.05 scale and 0.14 scale. Using the PMV models, the supply air parameters are optimized to minimize the deviation between the PMVs of the subzones and the respective thermal preferences. Case studies show that the proposed method can fulfill the thermal constraints of all subzones for thermal comfort, while the conventional method fails. The proposed method further improves thermal comfort by reducing the deviation of the achieved PMVs of subzones from the preferred ones by 17.6%–41.5% as compared with the conventional method. The proposed method is also promising for other collective ventilations (e.g., mixing ventilation and displacement ventilation)

    Using Personal Environmental Comfort Systems to Mitigate the Impact of Occupancy Prediction Errors on HVAC Performance

    Full text link
    Heating, Ventilation and Air Conditioning (HVAC) consumes a significant fraction of energy in commercial buildings. Hence, the use of optimization techniques to reduce HVAC energy consumption has been widely studied. Model predictive control (MPC) is one state of the art optimization technique for HVAC control which converts the control problem to a sequence of optimization problems, each over a finite time horizon. In a typical MPC, future system state is estimated from a model using predictions of model inputs, such as building occupancy and outside air temperature. Consequently, as prediction accuracy deteriorates, MPC performance--in terms of occupant comfort and building energy use--degrades. In this work, we use a custom-built building thermal simulator to systematically investigate the impact of occupancy prediction errors on occupant comfort and energy consumption. Our analysis shows that in our test building, as occupancy prediction error increases from 5\% to 20\% the performance of an MPC-based HVAC controller becomes worse than that of even a simple static schedule. However, when combined with a personal environmental control (PEC) system, HVAC controllers are considerably more robust to prediction errors. Thus, we quantify the effectiveness of PECs in mitigating the impact of forecast errors on MPC control for HVAC systems.Comment: 21 pages, 13 figure
    corecore