4,508 research outputs found
Influence of metallic artifact filtering on MEG signals for source localization during interictal epileptiform activity
Objective. Medical intractable epilepsy is a common condition that affects 40% of epileptic patients that generally have to undergo resective surgery. Magnetoencephalography (MEG) has been increasingly used to identify the epileptogenic foci through equivalent current dipole (ECD) modeling, one of the most accepted methods to obtain an accurate localization of interictal epileptiform discharges (IEDs). Modeling requires that MEG signals are adequately preprocessed to reduce interferences, a task that has been greatly improved by the use of blind source separation (BSS) methods. MEG recordings are highly sensitive to metallic interferences originated inside the head by implanted intracranial electrodes, dental prosthesis, etc and also coming from external sources such as pacemakers or vagal stimulators. To reduce these artifacts, a BSS-based fully automatic procedure was recently developed and validated, showing an effective reduction of metallic artifacts in simulated and real signals (Migliorelli et al 2015 J. Neural Eng. 12 046001). The main objective of this study was to evaluate its effects in the detection of IEDs and ECD modeling of patients with focal epilepsy and metallic interference. Approach. A comparison between the resulting positions of ECDs was performed: without removing metallic interference; rejecting only channels with large metallic artifacts; and after BSS-based reduction. Measures of dispersion and distance of ECDs were defined to analyze the results. Main results. The relationship between the artifact-to-signal ratio and ECD fitting showed that higher values of metallic interference produced highly scattered dipoles. Results revealed a significant reduction on dispersion using the BSS-based reduction procedure, yielding feasible locations of ECDs in contrast to the other two approaches. Significance. The automatic BSS-based method can be applied to MEG datasets affected by metallic artifacts as a processing step to improve the localization of epileptic foci.Postprint (published version
EOG Artifacts Removal in EEG Measurements for Affective Interaction
A brain-computer interface (BCI) is a direct link
between the brain and a computer. Multi-modal input with
BCI forms a promising solution for creating rich gaming
experience. Electroencephalography (EEG) measurement is the
sole necessary component for a BCI system. EEG signals
have the characteristics of large amount, multiple channels
and sensitive to noise. The amount of valuable information
derived from EEG signals is dependent on both the amount
of noises embedded in the original measurement and the
algorithms selected for postprocessing. Therefore, artifacts
removal in the preprocess step is crucial. Electrooculography
(EOG) signals are one of the major artifacts that often
appear in EEG measurement. In this paper, we compared two
different algorithms (Recursive Least Square (RLS) and Blind
Source Separation (BSS)) to investigate their performances on
removing EOG artifacts from EEG signals. Results indicate
that the performance of RLS algorithm is better than BSS
algorithm no matter whether there are any EOG reference
signals. For BSS algorithm, the performance is better when
EOG reference signals are available. These results show that for
a BCI system, EEG reference is often necessary. Performance
will be sacrificed if an EEG system cannot have any EOG
reference signals
Spatial Filtering Pipeline Evaluation of Cortically Coupled Computer Vision System for Rapid Serial Visual Presentation
Rapid Serial Visual Presentation (RSVP) is a paradigm that supports the
application of cortically coupled computer vision to rapid image search. In
RSVP, images are presented to participants in a rapid serial sequence which can
evoke Event-related Potentials (ERPs) detectable in their Electroencephalogram
(EEG). The contemporary approach to this problem involves supervised spatial
filtering techniques which are applied for the purposes of enhancing the
discriminative information in the EEG data. In this paper we make two primary
contributions to that field: 1) We propose a novel spatial filtering method
which we call the Multiple Time Window LDA Beamformer (MTWLB) method; 2) we
provide a comprehensive comparison of nine spatial filtering pipelines using
three spatial filtering schemes namely, MTWLB, xDAWN, Common Spatial Pattern
(CSP) and three linear classification methods Linear Discriminant Analysis
(LDA), Bayesian Linear Regression (BLR) and Logistic Regression (LR). Three
pipelines without spatial filtering are used as baseline comparison. The Area
Under Curve (AUC) is used as an evaluation metric in this paper. The results
reveal that MTWLB and xDAWN spatial filtering techniques enhance the
classification performance of the pipeline but CSP does not. The results also
support the conclusion that LR can be effective for RSVP based BCI if
discriminative features are available
Standardization of electroencephalography for multi-site, multi-platform and multi-investigator studies: Insights from the canadian biomarker integration network in depression
Subsequent to global initiatives in mapping the human brain and investigations of neurobiological markers for brain disorders, the number of multi-site studies involving the collection and sharing of large volumes of brain data, including electroencephalography (EEG), has been increasing. Among the complexities of conducting multi-site studies and increasing the shelf life of biological data beyond the original study are timely standardization and documentation of relevant study parameters. We presentthe insights gained and guidelines established within the EEG working group of the Canadian Biomarker Integration Network in Depression (CAN-BIND). CAN-BIND is a multi-site, multi-investigator, and multiproject network supported by the Ontario Brain Institute with access to Brain-CODE, an informatics platform that hosts a multitude of biological data across a growing list of brain pathologies. We describe our approaches and insights on documenting and standardizing parameters across the study design,
data collection, monitoring, analysis, integration, knowledge-translation, and data archiving phases of CAN-BIND projects. We introduce a custom-built EEG toolbox to track data preprocessing with open-access for the scientific community. We also evaluate the impact of variation in equipment setup on the accuracy of acquired data. Collectively, this work is intended to inspire establishing comprehensive and standardized guidelines for multi-site studies
An EEG-based perceptual function integration network for application to drowsy driving
© 2015 Elsevier B.V. All rights reserved. Drowsy driving is among the most critical causes of fatal crashes. Thus, the development of an effective algorithm for detecting a driver's cognitive state demands immediate attention. For decades, studies have observed clear evidence using electroencephalography that the brain's rhythmic activities fluctuate from alertness to drowsiness. Recognition of this physiological signal is the major consideration of neural engineering for designing a feasible countermeasure. This study proposed a perceptual function integration system which used spectral features from multiple independent brain sources for application to recognize the driver's vigilance state. The analysis of brain spectral dynamics demonstrated physiological evidenced that the activities of the multiple cortical sources were highly related to the changes of the vigilance state. The system performances showed a robust and improved accuracy as much as 88% higher than any of results performed by a single-source approach
Automatic EEG processing for the early diagnosis of traumatic brain injury
Traumatic Brain Injury (TBI) is recognized as an important cause of death and disabilities after an accident. The availability a tool for the early diagnosis of brain dysfunctions could greatly improve the quality of life of people affected by TBI and even prevent deaths. The contribution of the paper is a process including several methods for the automatic processing of electroencephalography (EEG) data, in order to provide a fast and reliable diagnosis of TBI. Integrated in a portable decision support system called EmerEEG, the TBI diagnosis is obtained using discriminant analysis based on quantitative EEG (qEEG) features extracted from data recordings after the automatic removal of artifacts. The proposed algorithm computes the TBI diagnosis on the basis of a model extracted from clinically-labelled EEG records. The system evaluations have confirmed the speed and reliability of the processing algorithms as well as the system's ability to deliver accurate diagnosis. The developed algorithms have achieved 79.1% accuracy in removing artifacts, and 87.85% accuracy in TBI diagnosis. Therefore, the developed system enables a short response time in emergency situations and provides a tool the emergency services could base their decision upon, thus preventing possibly miss-diagnosed injuries
Enhancing brain-computer interfacing through advanced independent component analysis techniques
A Brain-computer interface (BCI) is a direct communication system between a brain
and an external device in which messages or commands sent by an individual do not
pass through the brainâs normal output pathways but is detected through brain signals.
Some severe motor impairments, such as Amyothrophic Lateral Sclerosis, head
trauma, spinal injuries and other diseases may cause the patients to lose their muscle
control and become unable to communicate with the outside environment. Currently
no effective cure or treatment has yet been found for these diseases. Therefore using a
BCI system to rebuild the communication pathway becomes a possible alternative
solution. Among different types of BCIs, an electroencephalogram (EEG) based BCI
is becoming a popular system due to EEGâs fine temporal resolution, ease of use,
portability and low set-up cost. However EEGâs susceptibility to noise is a major
issue to develop a robust BCI. Signal processing techniques such as coherent
averaging, filtering, FFT and AR modelling, etc. are used to reduce the noise and
extract components of interest. However these methods process the data on the
observed mixture domain which mixes components of interest and noise. Such a
limitation means that extracted EEG signals possibly still contain the noise residue or
coarsely that the removed noise also contains part of EEG signals embedded.
Independent Component Analysis (ICA), a Blind Source Separation (BSS)
technique, is able to extract relevant information within noisy signals and separate the
fundamental sources into the independent components (ICs). The most common
assumption of ICA method is that the source signals are unknown and statistically
independent. Through this assumption, ICA is able to recover the source signals.
Since the ICA concepts appeared in the fields of neural networks and signal
processing in the 1980s, many ICA applications in telecommunications, biomedical
data analysis, feature extraction, speech separation, time-series analysis and data
mining have been reported in the literature. In this thesis several ICA techniques are
proposed to optimize two major issues for BCI applications: reducing the recording
time needed in order to speed up the signal processing and reducing the number of
recording channels whilst improving the final classification performance or at least
with it remaining the same as the current performance. These will make BCI a more
practical prospect for everyday use.
This thesis first defines BCI and the diverse BCI models based on different
control patterns. After the general idea of ICA is introduced along with some
modifications to ICA, several new ICA approaches are proposed. The practical work
in this thesis starts with the preliminary analyses on the Southampton BCI pilot
datasets starting with basic and then advanced signal processing techniques. The
proposed ICA techniques are then presented using a multi-channel event related
potential (ERP) based BCI. Next, the ICA algorithm is applied to a multi-channel
spontaneous activity based BCI. The final ICA approach aims to examine the
possibility of using ICA based on just one or a few channel recordings on an ERP
based BCI.
The novel ICA approaches for BCI systems presented in this thesis show that ICA
is able to accurately and repeatedly extract the relevant information buried within
noisy signals and the signal quality is enhanced so that even a simple classifier can
achieve good classification accuracy. In the ERP based BCI application, after multichannel
ICA the data just applied to eight averages/epochs can achieve 83.9%
classification accuracy whilst the data by coherent averaging can reach only 32.3%
accuracy. In the spontaneous activity based BCI, the use of the multi-channel ICA
algorithm can effectively extract discriminatory information from two types of singletrial
EEG data. The classification accuracy is improved by about 25%, on average,
compared to the performance on the unpreprocessed data. The single channel ICA
technique on the ERP based BCI produces much better results than results using the
lowpass filter. Whereas the appropriate number of averages improves the signal to
noise rate of P300 activities which helps to achieve a better classification. These
advantages will lead to a reliable and practical BCI for use outside of the clinical
laboratory
- âŠ