46,053 research outputs found

    Flexible electroencephalogram (EEG) headband

    Get PDF
    Headband incorporates sensors which are embedded in sponges and are exposed only on surface that touches skin. Electrode sponge system is continually fed electrolyte through forced feed vacuum system. Headband may be used for EEG testing in hospitals, clinical laboratories, rest homes, and law enforcement agencies

    Fluctuation Analysis of Human Electroencephalogram

    Get PDF
    The scaling behaviors of the human electroencephalogram (EEG) time series are studied using detrended fluctuation analysis. Two scaling regions are found in nearly every channel for all subjects examined. The scatter plot of the scaling exponents for all channels (up to 129) reveals the complicated structure of a subject's brain activity. Moment analyses are performed to extract the gross features of all the scaling exponents, and another universal scaling behavior is identified. A one-parameter description is found to characterize the fluctuation properties of the nonlinear behaviors of the brain dynamics.Comment: 4 pages in RevTeX + 6 figures in ep

    On-Off Intermittency in Time Series of Spontaneous Paroxysmal Activity in Rats with Genetic Absence Epilepsy

    Get PDF
    Dynamic behavior of complex neuronal ensembles is a topic comprising a streamline of current researches worldwide. In this article we study the behavior manifested by epileptic brain, in the case of spontaneous non-convulsive paroxysmal activity. For this purpose we analyzed archived long-term recording of paroxysmal activity in animals genetically susceptible to absence epilepsy, namely WAG/Rij rats. We first report that the brain activity alternated between normal states and epilepsy paroxysms is the on-off intermittency phenomenon which has been observed and studied earlier in the different nonlinear systems.Comment: 11 pages, 6 figure

    Qualitative and Quantitative Characteristics of the Electroencephalogram in Normal Horses during Administration of Inhaled Anesthesia.

    Get PDF
    BackgroundThe effects of anesthesia on the equine electroencephalogram (EEG) after administration of various drugs for sedation, induction, and maintenance are known, but not that the effect of inhaled anesthetics alone for EEG recording.ObjectiveTo determine the effects of isoflurane and halothane, administered as single agents at multiple levels, on the EEG and quantitative EEG (qEEG) of normal horses.AnimalsSix healthy horses.MethodsProspective study. Digital EEG with video and quantitative EEG (qEEG) were recorded after the administration of one of the 2 anesthetics, isoflurane or halothane, at 3 alveolar doses (1.2, 1.4 and 1.6 MAC). Segments of EEG during controlled ventilation (CV), spontaneous ventilation (SV), and with peroneal nerve stimulation (ST) at each MAC multiple for each anesthetic were selected, analyzed, and compared. Multiple non-EEG measurements were also recorded.ResultsSpecific raw EEG findings were indicative of changes in the depth of anesthesia. However, there was considerable variability in EEG between horses at identical MAC multiples/conditions and within individual horses over segments of a given epoch. Statistical significance for qEEG variables differed between anesthetics with bispectral index (BIS) CV MAC and 95% spectral edge frequency (SEF95) SV MAC differences in isoflurane only and median frequency (MED) differences in SV MAC with halothane only.Conclusions and clinical importanceUnprocessed EEG features (background and transients) appear to be beneficial for monitoring the depth of a particular anesthetic, but offer little advantage over the use of changes in mean arterial pressure for this purpose

    Pain-related Somato Sensory Evoked Potentials: A potential new tool to improve the prognostic prediction of coma after cardiac arrest

    Get PDF
    INTRODUCTION: Early prediction of a good outcome in comatose patients after cardiac arrest still remains an unsolved problem. The main aim of the present study was to examine the accuracy of middle-latency SSEP triggered by a painful electrical stimulation on median nerves to predict a favorable outcome. METHODS: No- and low-flow times, pupillary reflex, Glasgow motor score and biochemical data were evaluated at ICU admission. The following were considered within 72 h of cardiac arrest: highest creatinine value, hyperthermia occurrence, EEG, SSEP at low- (10 mA) and high-intensity (50 mA) stimulation, and blood pressure reactivity to 50 mA. Intensive care treatments were also considered. Data were compared to survival, consciousness recovery and 6-month CPC (Cerebral Performance Category). RESULTS: Pupillary reflex and EEG were statistically significant in predicting survival; the absence of blood pressure reactivity seems to predict brain death within 7 days of cardiac arrest. Middle- and short-latency SSEP were statistically significant in predicting consciousness recovery, and middle-latency SSEP was statistically significant in predicting 6-month CPC outcome. The prognostic capability of 50 mA middle-latency-SSEP was demonstrated to occur earlier than that of EEG reactivity. CONCLUSIONS: Neurophysiological evaluation constitutes the key to early information about the neurological prognostication of postanoxic coma. In particular, the presence of 50 mA middle-latency SSEP seems to be an early and reliable predictor of good neurological outcome, and its absence constitutes a marker of poor prognosis. Moreover, the absence 50 mA blood pressure reactivity seems to identify patients evolving towards the brain death

    Electroencephalogram of Healthy Horses During Inhaled Anesthesia.

    Get PDF
    BackgroundPrevious study of the diagnostic validity of electroencephalography (EEG) to detect abnormalities in equine cerebral cortical function relied on the administration of various drugs for sedation, induction, and maintenance of general anesthesia but used identical criteria to interpret recordings.ObjectivesTo determine the effects of 2 inhalation anesthetics on the EEG of healthy horses.AnimalsSix healthy horses.MethodsProspective study. After the sole administration of one of either isoflurane or halothane at 1.2, 1.4, and 1.6 times the minimum alveolar concentration, EEG was recorded during controlled ventilation, spontaneous ventilation, and nerve stimulation.ResultsBurst suppression was observed with isoflurane, along with EEG events that resembled epileptiform discharges. Halothane results were variable between horses, with epileptiform-like discharges and bursts of theta, alpha, and beta recorded intermittently. One horse died and 2 were euthanized as the result of anesthesia-related complications.Conclusions and clinical importanceThe results of this study indicate that the effects of halothane and isoflurane on EEG activity in the normal horse can be quite variable, even when used in the absence of other drugs. It is recommended that equine EEG be performed without the use of these inhalation anesthetics and that general anesthesia be induced and maintained by other contemporary means

    Classification of Epileptic EEG Signals by Wavelet based CFC

    Full text link
    Electroencephalogram, an influential equipment for analyzing humans activities and recognition of seizure attacks can play a crucial role in designing accurate systems which can distinguish ictal seizures from regular brain alertness, since it is the first step towards accomplishing a high accuracy computer aided diagnosis system (CAD). In this article a novel approach for classification of ictal signals with wavelet based cross frequency coupling (CFC) is suggested. After extracting features by wavelet based CFC, optimal features have been selected by t-test and quadratic discriminant analysis (QDA) have completed the Classification.Comment: Electroencephalogram; Wavelet Decomposition; Cross Frequency Coupling;Quadratic Discriminant Analysis; T-test Feature Selectio

    A technique for automatic real time scoring of several simultaneous sleep electroencephalograms

    Get PDF
    Automatic real-time scoring of simultaneous sleep electroencephalogram

    Comprehensive Spectral Analysis of Human EEG GENERATORS in Posterior Cerebral Regions

    Get PDF
    Human electroencephalogram generator spectral analysis in posterior cerebral region
    corecore