    On the Use of the p-q Theory for Harmonic Current Cancellation with Shunt Active Filters

    Get PDF
    Discussion and mathematical proof on necessary and sufficient conditions for the application of the {p-q} theory for compensating the harmonic currents consumed by non-linear load using a shunt active filter are presented. These conditions over instantaneous active and reactive powers were not addressed before and must be considered on the design of new control strategies based on {p-q} theory. Theoretical demonstration is proposed and an application example with simulations results is used to validate the theoretical results

    Digital Current-Control Schemes

    Get PDF
    The paper is about comparing the performance of digital signal processor-based current controllers for three-phase active power filters. The wide use of nonlinear loads, such as front-end rectifiers connected to the power distribution systems for dc supply or inverter-based applications, causes significant power quality degradation in power distribution networks in terms of current/voltage harmonics, power factor, and resonance problems. Passive LC filters (together with capacitor banks for reactive power compensation) are simple, low-cost, and high-efficiency solution

    Current Control of Self-Excited Induction Generator using Shunt Active Filter

    Get PDF
    Self-energized impelling generators are great applicants for wind controlled power era, particularly in remote territories, in light of the fact that they needn't bother with an outside force supply to process the excitation attractive field. A three-stage actuation machine could be made to fill in as a self-energized instigation generator where a three-stage capacitor bank is joined over the stator terminals to supply the touchy force necessity of a heap and generator. A standout amongst the most well-known issues when uniting little renewable vitality frameworks to the electric burden is it can infuse symphonious parts that may fall apart the force quality. In the late decades, the world has seen a development in the utilization of non-direct loads. The sounds causes issues in force frameworks and in customer items, for example, gear overheating, capacitor blowing, engine vibration, unnecessary nonpartisan momentums and low power variable. Shunt active power filter compensates current harmonics by injecting equal-but-opposite harmonic compensating currents into the grid. This paper presents a new control strategy based on shunt active power filter for controlling the current of self-excited induction generator when generator is connected to a nonlinear load. This paper also represents the analysis and modelling of dynamic model of SEIG in MATLAB/ SIMULINK. Basically a strategy based on an active power filter (APF) for controlling the current and power quality of the self-excited induction generator (SEIG) have been presented in this paper. The shunt active power filter was implemented using a three phase PWM current controlled voltage source inverter (VSI) and connected to the wind generator and loads in order to compensate the current harmonics and reactive power

    Direct control strategy for a four-level three-phase flying-capacitor inverter

    Get PDF
    A direct predictive control strategy is proposed for a three-phase four-level flying-capacitor (FC) inverter in this paper. The balancing of the FC voltages, a challenge in applications with small capacitors and low switching frequencies, is done without any modulation, simply using tables calculated offline. These allow the realization of fast-dynamics output currents with reduced dv/dt in the output voltages and reduced switching frequencies. Moreover, no interharmonics are created when operating at low switching frequencies and with reference currents containing multiple harmonic components, which is a key feature for active power filters. Simulations and experimental results are presented to demonstrate the excellent performance of the direct control strategy in comparison with a conventional pulsewidth-modulation control technique, mostly for operation at low switching frequencies

    DSOGI-PLL based power control method to mitigate control errors under disturbances of grid connected hybrid renewable power systems

    Get PDF
    The control of power converter devices is one of the main research lines in interfaced renewable energy sources, such as solar cells and wind turbines. Therefore, suitable control algorithms should be designed in order to regulate power or current properly and attain a good power quality for some disturbances, such as voltage sag/swell, voltage unbalances and fluctuations, long interruptions, and harmonics. Various synchronisation techniques based control strategies are implemented for the hybrid power system applications under unbalanced conditions in literature studies. In this paper, synchronisation algorithms based Proportional-Resonant (PR) power/current controller is applied to the hybrid power system (solar cell + wind turbine + grid), and Dual Second Order Generalized Integrator-Phase Locked Loop (DSOGI-PLL) based PR controller in stationary reference frame provides a solution to overcome these problems. The influence of various cases, such as unbalance, and harmonic conditions, is examined, analysed and compared to the PR controllers based on DSOGI-PLL and SRF-PLL. The results verify the effectiveness and correctness of the proposed DSOGI-PLL based power control method

    Power Quality Improvement by Harmonic Reduction Using Three Phase Shunt Active Power Filter with p-q & d-q Current Control Strategy

    Get PDF
    With the widespread use of power electronics devices such as rectifier, inverter etc. in power system causes serious problem relating to power quality. One of such problem is generation of current and voltage harmonics causing distortion of load waveform, voltage fluctuation, voltage dip, heating of equipment etc. Also presence of non-linear loads such as UPS, SMPS, speed drives etc. causes the generation of current harmonics in power system. They draw reactive power components of current from the AC mains, hence causing disturbance in supply current wave form. Thus to avoid the consequences of harmonics we have to compensate the harmonic component in power utility system. Among various method used, one of the effective method to reduce harmonic in power system is the use of Shunt Active Power Filter (SAPF). This Paper gives detail performance analysis of SAPF under two current control strategy namely, instantaneous active and reactive power theory (p-q) and synchronous frame reference theory (d-q) and their comparative analysis to justify one of the method better over other. In both method a reference current is generated for the filter which compensate either reactive power or harmonic current component in power system. In this paper, a current controller known harmonic current controller is described which is used provide corrective gating sequence of the IGBT inverter and thus helps to remove harmonics component

    Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems

    Get PDF
    This paper deals with a shunt active filter which will be installed by an electric utility, putting much emphasis on the control strategy and the best point of installation of the shunt active filter on a feeder in a power distribution system. The objective of the shunt active filter is to damp harmonic propagation, which results from harmonic resonance between many capacitors for power factor improvement and line inductors in the feeder, rather than to minimize voltage distortion throughout the feeder. Harmonic mitigation is a welcome “by-product” of the shunt active filter, which comes from damping of harmonic propagation. This paper concludes that the shunt active filter based on detection of voltage at the point of installation is superior in stability to others, and that the best site selection is not the beginning terminal but the end terminal of the primary line in the feeder. Computer simulation is performed to verify the validity and effectiveness of the shunt active filter by means of an analog circuit simulator, which is characterized by installing it on a feeder of a radial distribution system in a residential area</p

    Power quality improvement using passive shunt filter, TCR and TSC combination

    Get PDF
    Power system harmonics are a menace to electric power systems with disastrous consequences. The line current harmonics cause increase in losses, instability, and also voltage distortion. With the proliferation of the power electronics converters and increased use of magnetic, power lines have become highly polluted. Both passive and active filters have been used near harmonic producing loads or at the point of common coupling to block current harmonics. Shunt filters still dominate the harmonic compensation at medium/high voltage level, whereas active filters have been proclaimed for low/medium voltage ratings. With diverse applications involving reactive power together with harmonic compensation, passive filters are found suitable [41]. Passive filtering has been preferred for harmonic compensation in distribution systems due to low cost, simplicity, reliability, and control less operation [42]. The uncontrolled ac-dc converter suffers from operating problems of poor power factor, injection of harmonics into the ac mains, variations in dc link voltage of input ac supply, equipment overheating due to harmonic current absorption, voltage distortion due to the voltage drop caused by harmonic currents flowing through system impedances, interference on telephone and communication line etc. The circuit topologies such as passive filters, ac-dc converter, based improved power quality ac-dc converters are designed, modeled and implemented. The main emphasis of this investigation has been on a compactness of configurations, simplicity in control, reduction in rating of components, thus finally leading to saving in overall cost. Based on thesis considerations, a wide range of configurations of power quality mitigators are developed, which is expected to provide detailed exposure to design engineers to choose a particular configuration for a specific application under the given constraints of economy and desired performance. For bidirectional power flow applications, the current source converter is designed and simulated with R-L load. The necessary modeling and simulations are carried out in MATLAB environment using SIMULINK and power system block set toolboxes. The behavior of different configurations of passive tuned filters on power quality is studied. One of the way out to resolve the issue of reactive power would be using filters and TCR, TSC with combination in the power system. Installing a filter for nonlinear loads connected in power system would help in reducing the harmonic effect. The filters are widely used for reduction of harmonics. With the increase of nonlinear loads in the power system, more and more filters are required. The combinations of passive filters with TCR and TSC are also designed and analyzed to improve the power quality at ac mains. This scheme has resulted in improved power quality with overall reduced rating of passive components used in front end ac-dc converters with R-L load

    Interleaved Buck Converter Based Shunt Active Power Filter with Shoot-through Elimination for Power Quality Improvement

    Get PDF
    The “shoot-through” phenomenon defined as the rush of current that occurs while both the devices are ON at the same time of a particular limb is one of the most perilous failure modes encountered in conventional inverter circuits of active power filter (APF). Shoot-through phenomenon has few distinct disadvantages like; it introduces typical ringing, increases temperature rise in power switches, causes higher Electromagnetic Interference (EMI) and reduces the efficiency of the circuit. To avert the “shoot-through”, dead time control could be added, but it deteriorates the harmonic compensation level. This dissertation presents active power filters (APFs) based on interleaved buck (IB) converter. Compared to traditional shunt active power filters, the presented IB APFs have enhanced reliability with no shoot-through phenomenon. The instantaneous active and reactive power (p-q) scheme and instantaneous active and reactive current component (id-iq) control scheme has been implemented to mitigate the source current harmonics. Type-1 and Type-2 fuzzy logic controller with different membership functions (MFs) viz. Triangular, Trapezoidal and Gaussian have been implemented for the optimal harmonic compensation by controlling the dc-link voltage and minimizing the undesirable losses occurred inside the APF. Additionally, the adaptive hysteresis band current controller (AHBCC) is being implemented to get the nearly constant switching frequency. The performance of the control strategies and controllers for the presented IB APF topologies has been evaluated in terms of harmonic mitigation and dc-link voltage regulation under sinusoidal, unbalanced sinusoidal and non-sinusoidal voltage source condition. This dissertation is concerned with the different topologies of 3-phase 4-wire IB APFs viz. split capacitor (2C) topology, 4-leg (4L) topology, transformer based full-bridge IB APF or single capacitor based FB IB APF (1C 3 FB IB APF) and full-bridge IB APF (FB IB APF) for low to medium power application. Moreover, APF topology is now being expanded to multilevel VSIs for high power application. Thanks to flexible modular design, transformerless connection, extended voltage and power output, less maintenance and higher fault tolerance, the cascade inverters are good candidates for active power filters with the utility of high power application. The cascaded FB IB APF is modelled with no shoot-through phenomenon by using multicarrier phase shifted PWM scheme. Extensive simulations have been carried out in the MATLAB / Simulink environment and also verified in the OPAL-RT LAB using OP5142-Spartan 3 FPGA to support the feasibility of presented IB APF topologies, control strategies and controllers during steady and dynamic condition. The performance shows that IB-APF topologies bring the THD of the source current well below 5% adhering to IEEE-519 standard. A comparison has also been made, based on SDP (switch device power) between the IB-APF topologies