Recommended from our members
Optimizing Radiant Systems for Energy Efficiency and Comfort
Radiant cooling and heating systems provide an opportunity to achieve significant energy savings, peak demand reduction, load shifting, and thermal comfort improvements compared to conventional all-air systems. As a result, application of these systems has increased in recent years, particularly in zero-net-energy (ZNE) and other advanced low-energy buildings. Despite this growth, completed installations to date have demonstrated that controls and operation of radiant systems can be challenging due to a lack of familiarity within the heating, ventilation, and air-conditioning (HVAC) design and operations professions, often involving new concepts (particularly related to the slow response in high thermal mass radiant systems). To achieve the significant reductions in building energy use proposed by California Public Utilities Commission’s (CPUC’s) Energy Efficiency Strategic Plan that all new non-residential buildings be ZNE by 2030, it is critical that new technologies that will play a major role in reaching this goal be applied in an effective manner. This final report describes the results of a comprehensive multi-faceted research project that was undertaken to address these needed enhancements to radiant technology by developing the following: (1) sizing and operation tools (currently unavailable on the market) to provide reliable methods to take full advantage of the radiant systems to provide improved energy performance while maintaining comfortable conditions, (2) energy, cost, and occupant comfort data to provide real world examples of energy efficient, affordable, and comfortable buildings using radiant systems, and (3) Title-24 and ASHRAE Standards advancements to enhance the building industry’s ability to achieve significant energy efficiency goals in California with radiant systems. The research team used a combination of full-scale fundamental laboratory experiments, whole-building energy simulations and simplified tool development, and detailed field studies and control demonstrations to assemble the new information, guidance and tools necessary to help the building industry achieve significant energy efficiency goals for radiant systems in California
History and development of validation with the ESP-r simulation program
It is well recognised that validation of dynamic building simulation programs is a long-term complex task. There have been many large national and international efforts that have led to a well-established validation methodology comprising analytical, inter-program comparison and empirical validation elements, and a significant number of tests have been developed. As simulation usage increases, driven by such initiatives as the European Energy Performance of Buildings Directive, such tests are starting to be incorporated into national and international standards. Although many program developers have run many of the developed tests, there does not appear to have been a systematic attempt to incorporate such tests into routine operation of the simulation programs. This paper reports work undertaken to address this deficiency. The paper summarizes the tests that have been applied to the simulation program ESP-r. These tests have been developed within International Energy Agency Annexes, within CEN standards, within various large-scale national projects, and by the UK's Chartered Institution of Building Services Engineers. The structure used to encapsulate the tests allows developers to ensure that recent code modifications have not resulted in unforeseen impacts on program predictions, and allows users to check for themselves against benchmarks
Integrated solar energy and absorption cooling model for HVAC (heating, ventilating, and air conditioning) applications in buildings
The demands in production and associate costs at power generation through non renewable resources are increasing at an alarming rate. Solar energy is one of the renewable resource that has the potential to minimize this increase. Utilization of solar energy have been concentrated mainly on heating application. The use of solar energy in cooling systems in building would benefit greatly achieving the goal of non-renewable energy minimization.
The approaches of solar energy heating system research done by initiation such as University of Wisconsin at Madison and building heat flow model research conducted by Oklahoma State University can be used to develop and optimize solar cooling building system.
The research uses two approaches to develop a Graphical User Interface (GUI) software for an integrated solar absorption cooling building model, which is capable of simulating and optimizing the absorption cooling system using solar energy as the main energy source to drive the cycle.
The software was then put through a number of litmus test to verify its integrity. The litmus test was conducted on various building cooling system data sets of similar applications around the world. The output obtained from the software developed were identical with established experimental results from the data sets used.
Software developed by other research are catered for advanced users. The software developed by this research is not only reliable in its code integrity but also through its integrated approach which is catered for new entry users.
Hence, this dissertation aims to correctly model a complete building with the absorption cooling system in appropriate climate as a cost effective alternative to conventional vapor compression system
Recommended from our members
Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements
The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings.
Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs.
The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation.
EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence.
Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass.
The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here
Energy and thermal modelling of an office building to develop an artificial neural networks model
[EN] Nowadays everyone should be aware of the importance of reducing CO2 emissions which produce the greenhouse effect. In the field of construction, several options are proposed to reach nearly-Zero Energy Building (nZEB) standards. Obviously, before undertaking a modification in any part of a building focused on improving the energy performance, it is generally better to carry out simulations to evaluate its effectiveness. Using Artificial Neural Networks (ANNs) allows a digital twin of the building to be obtained for specific characteristics without using very expensive software. This can simulate the effect of a single or combined intervention on a particular floor or an event on the remaining floors. In this paper, an example has been developed based on ANN. The results show a reasonable correlation between the real data of the Operative Temperature with the Energy Consumption and their estimates obtained through an ANN model, trained using an hourly basis, on each of the floors of an office building. This model confirms it is possible to obtain simulations in existing public buildings with an acceptable degree of precision and without laborious modelling, which would make it easier to achieve the nZEB target, especially in existing public office buildings
Recommended from our members
Ceiling-fan-integrated air conditioning: Airflow and temperature characteristics of a sidewall-supply jet interacting with a ceiling fan
Ceiling-Fan-Integrated Air Conditioning (CFIAC) is a proposed system that can greatly increase buildings’ cooling efficiency. In it, terminal supply ducts and diffusers are replaced by vents/nozzles, jetting supply air toward ceiling fans that serve to mix and distribute it within the room. Because of the fans’ air movement, the system provides comfort at higher room temperatures than in conventional commercial/ institutional/retail HVAC. We have experimentally evaluated CFIAC in a test room. This paper covers the distributions of air-speed, temperature, and calculated comfort level throughout the room. Two subsequent papers report tests of human subject comfort and ventilation effectiveness in the same experimental conditions. The room’s supply air emerged from a high-sidewall vent directed toward a ceiling fan on the jet centerline; we also tested this same jet on a fan located off to the side of the jet. Primary variables are: ceiling fan flow volumes in downward and upward directions, supply air volume, and room-vs-supply temperature difference. Velocity, turbulence, and temperature distributions are presented for vertical and horizontal transects of the room. The occupied zone is then evaluated for velocity and temperature non-uniformity, and for comfort as predicted by the ASHRAE Standard 55 elevated air speed method. We show that temperatures are well-mixed and uniform across the room for all of the fan-on configurations, for fans both within or out of the supply jet centerline. The ceiling fan flow dominates the CFIAC airflow, and even though non-uniform is capable of providing comfortable conditions throughout the occupied area of the room
Recommended from our members
High-Performance Integrated Window and Façade Solutions for California
The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California
Building Management System - Energy Efficiency Management
Building Management System should be a hot topic during this century. The potential for energy saving that BMS gives to a building is very high. BMS has started to implementation in commercial buildings to enable monitoring and control of the various intelligent systems like Heating Ventilation and Air - Conditioning (HVAC), safety, access and lighting systems. Heating Ventilation and Air - Conditioning (HVAC) systems in buildings must be complemented with a good control scheme to maintain comfort under any load situations. Efficient HVAC control usually is the most cost-effective option to improve the energy efficiency of a building. However, HVAC procedures are nonlinear, and features change on a seasonal basis so the effect of changing the control strategy is usually difficult to predict. Intention of this thesis is to reduce energy consumptions by defining new HVAC control strategies and design a technical solution for a new commercial building. To study the potential for energy savings and to redefine control situations, we have figure out - concept a new commercial building
The formulation, characteristics and solution of HVAC system optimized design problems
The formulation, characteristics and solution of HVAC system optimized design problem
- …