1,678 research outputs found

    Human-activity-centered measurement system:challenges from laboratory to the real environment in assistive gait wearable robotics

    Get PDF
    Assistive gait wearable robots (AGWR) have shown a great advancement in developing intelligent devices to assist human in their activities of daily living (ADLs). The rapid technological advancement in sensory technology, actuators, materials and computational intelligence has sped up this development process towards more practical and smart AGWR. However, most assistive gait wearable robots are still confined to be controlled, assessed indoor and within laboratory environments, limiting any potential to provide a real assistance and rehabilitation required to humans in the real environments. The gait assessment parameters play an important role not only in evaluating the patient progress and assistive device performance but also in controlling smart self-adaptable AGWR in real-time. The self-adaptable wearable robots must interactively conform to the changing environments and between users to provide optimal functionality and comfort. This paper discusses the performance parameters, such as comfortability, safety, adaptability, and energy consumption, which are required for the development of an intelligent AGWR for outdoor environments. The challenges to measuring the parameters using current systems for data collection and analysis using vision capture and wearable sensors are presented and discussed

    Master of Science

    Get PDF
    thesisComputing and data acquisition have become an integral part of everyday life. From reading emails on cell phones to kids playing with motion sensing game consoles, we are surrounded with sensors and mobile computing devices. As the availability of powerful computing devices increases, applications in previously limited environments become possible. Training devices in rehabilitation are becoming increasingly common and more mobile. Community based rehabilitative devices are emerging that embrace these mobile advances. To further the flexibility of devices used in rehabilitation, research has explored the use of smartphones as a means to process data and provide feedback to the user. In combination with sensor embedded insoles, smartphones provide a powerful tool for the clinician in gathering data and as a standalone training tool in rehabilitation. This thesis presents the continuing research of sensor based insoles, feedback systems and increasing the capabilities of the Adaptive Real-Time Instrumentation System for Tread Imbalance Correction, or ARTISTIC, with the introduction of ARTISTIC 2.0. To increase the capabilities of the ARTISTIC an Inertial Measurement Unit (IMU) was added, which gave the system the ability to quantify the motion of the gait cycle and, more specifically, determine stride length. The number of sensors in the insole was increased from two to ten, as well as placing the microprocessor and a vibratory motor in the insole. The transmission box weight was reduced by over 50 percent and the volume by over 60 percent. Stride length was validated against a motion capture system and found the average stride length to be within 2.7 ± 6.9 percent. To continue the improvement of the ARTISTIC 2.0, future work will include implementing real-time stride length feedback

    Master of Science

    Get PDF
    thesisComputing and data acquisition have become an integral part of everyday life. From reading emails on a cell phone, to kids playing with motion sensing game consoles, we are surrounded with sensors and mobile devices. As the availability of powerful mobile computing devices expands, the road is paved for applications in previously limited environments. Rehabilitative devices are emerging that embrace these mobile advances. Research has explored the use of smartphones in rehabilitation as a means to process data and provide feedback in conjunction with established rehabilitative methods. Smartphones, combined with sensor embedded insoles, provide a powerful tool for the clinician in gathering data and may act as a standalone training technique. This thesis presents continuing research of a sensor integrated insole system that provides real-time feedback through a mobile platform, the Adaptive Real-Time Instrumentation System for Tread Imbalance Correction (ARTISTIC). The system interfaces a wireless instrumented insole with an Android smartphone application to receive gait data and provide sensory feedback to modify gait patterns. Revisions to the system hardware, software, and feedback modes brought about the introduction of the ARTISTIC 2.0. The number of sensors in the insole was increased from two to 10. The microprocessor and a vibrotactile motor were embedded in the insole and the communications box was reduced in size and weight by more than 50%. Stance time iv measurements were validated against force plate equipment and found to be within 13.5 ± 3.3% error of force plate time measurements. Human subjects were tested using each of the feedback modes to alter gait symmetry. Results from the testing showed that more than one mode of feedback caused a statistically significant change in gait symmetry ratios (p < 0.05). Preference of feedback modes varied among subjects, with the majority agreeing that several feedback modes made a difference in their gait. Further improvements will prepare the ARTISTIC 2.0 for testing in a home environment for extended periods of time and improve data capture techniques, such as including a database in the smartphone application

    Inertial sensor-based knee flexion/extension angle estimation

    Get PDF
    A new method for estimating knee joint flexion/extension angles from segment acceleration and angular velocity data is described. The approach uses a combination of Kalman filters and biomechanical constraints based on anatomical knowledge. In contrast to many recently published methods, the proposed approach does not make use of the earth’s magnetic field and hence is insensitive to the complex field distortions commonly found in modern buildings. The method was validated experimentally by calculating knee angle from measurements taken from two IMUs placed on adjacent body segments. In contrast to many previous studies which have validated their approach during relatively slow activities or over short durations, the performance of the algorithm was evaluated during both walking and running over 5 minute periods. Seven healthy subjects were tested at various speeds from 1 to 5 miles/hour. Errors were estimated by comparing the results against data obtained simultaneously from a 10 camera motion tracking system (Qualysis). The average measurement error ranged from 0.7 degrees for slow walking (1 mph) to 3.4 degrees for running (5mph). The joint constraint used in the IMU analysis was derived from the Qualysis data. Limitations of the method, its clinical application and its possible extension are discussed

    Objective assessment of movement disabilities using wearable sensors

    Full text link
    The research presents a series of comprehensive analyses based on inertial measurements obtained from wearable sensors to quantitatively describe and assess human kinematic performance in certain tasks that are most related to daily life activities. This is not only a direct application of human movement analysis but also very pivotal in assessing the progression of patients undergoing rehabilitation services. Moreover, the detailed analysis will provide clinicians with greater insights to capture movement disorders and unique ataxic features regarding axial abnormalities which are not directly observed by the clinicians

    An Instrumented Walking-Aid to Assess and Retrain Gait

    Get PDF
    An instrumented walking-aid, the iWA system, has been developed to measure kinematic and kinetic properties of walking aid (WA) use and deliver feedback to improve gait. The clinical requirements, technical specification and design of the system are developed through clinical collaboration. The development of the system is described, including hardware components and data analysis used to process the measured data for assessment. The system measurements are validated under controlled laboratory conditions. The iWA system is evaluated in a typical UK clinical environment by a participant in a rehabilitation session. The resultant data successfully capture the quality of the participant’s walking aid use and agree with clinical opinion, supporting the efficacy of this approach

    Wearable Movement Sensors for Rehabilitation: From Technology to Clinical Practice

    Get PDF
    This Special Issue shows a range of potential opportunities for the application of wearable movement sensors in motor rehabilitation. However, the papers surely do not cover the whole field of physical behavior monitoring in motor rehabilitation. Most studies in this Special Issue focused on the technical validation of wearable sensors and the development of algorithms. Clinical validation studies, studies applying wearable sensors for the monitoring of physical behavior in daily life conditions, and papers about the implementation of wearable sensors in motor rehabilitation are under-represented in this Special Issue. Studies investigating the usability and feasibility of wearable movement sensors in clinical populations were lacking. We encourage researchers to investigate the usability, acceptance, feasibility, reliability, and clinical validity of wearable sensors in clinical populations to facilitate the application of wearable movement sensors in motor rehabilitation

    Low-Cost Sensors and Biological Signals

    Get PDF
    Many sensors are currently available at prices lower than USD 100 and cover a wide range of biological signals: motion, muscle activity, heart rate, etc. Such low-cost sensors have metrological features allowing them to be used in everyday life and clinical applications, where gold-standard material is both too expensive and time-consuming to be used. The selected papers present current applications of low-cost sensors in domains such as physiotherapy, rehabilitation, and affective technologies. The results cover various aspects of low-cost sensor technology from hardware design to software optimization

    Gait analysis in a box: A system based on magnetometer-free IMUs or clusters of optical markers with automatic event detection

    Get PDF
    Gait analysis based on full-body motion capture technology (MoCap) can be used in rehabilitation to aid in decision making during treatments or therapies. In order to promote the use of MoCap gait analysis based on inertial measurement units (IMUs) or optical technology, it is necessary to overcome certain limitations, such as the need for magnetically controlled environments, which affect IMU systems, or the need for additional instrumentation to detect gait events, which affects IMUs and optical systems. We present a MoCap gait analysis system called Move Human Sensors (MH), which incorporates proposals to overcome both limitations and can be configured via magnetometer-free IMUs (MH-IMU) or clusters of optical markers (MH-OPT). Using a test–retest reliability experiment with thirty-three healthy subjects (20 men and 13 women, 21.7 ± 2.9 years), we determined the reproducibility of both configurations. The assessment confirmed that the proposals performed adequately and allowed us to establish usage considerations. This study aims to enhance gait analysis in daily clinical practice
    • …
    corecore