47 research outputs found

    Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion

    Get PDF
    Motion tracking based on commercial inertial measurements units (IMUs) has been widely studied in the latter years as it is a cost-effective enabling technology for those applications in which motion tracking based on optical technologies is unsuitable. This measurement method has a high impact in human performance assessment and human-robot interaction. IMU motion tracking systems are indeed self-contained and wearable, allowing for long-lasting tracking of the user motion in situated environments. After a survey on IMU-based human tracking, five techniques for motion reconstruction were selected and compared to reconstruct a human arm motion. IMU based estimation was matched against motion tracking based on the Vicon marker-based motion tracking system considered as ground truth. Results show that all but one of the selected models perform similarly (about 35 mm average position estimation error)

    Orientation Estimation Through Magneto-Inertial Sensor Fusion: A Heuristic Approach for Suboptimal Parameters Tuning

    Get PDF
    Magneto-Inertial Measurement Units (MIMUs) are a valid alternative tool to optical stereophotogrammetry in human motion analysis. The orientation of a MIMU may be estimated by using sensor fusion algorithms. Such algorithms require input parameters that are usually set using a trial-and-error (or grid-search ) approach to find the optimal values. However, using trial-and-error requires a known reference orientation, a circumstance rarely occurring in real-life applications. In this article, we present a way to suboptimally set input parameters, by exploiting the assumption that two MIMUs rigidly connected are expected to show no orientation difference during motion. This approach was validated by applying it to the popular complementary filter by Madgwick et al. and tested on 18 experimental conditions including three commercial products, three angular rates, and two dimensionality motion conditions. Two main findings were observed: i) the selection of the optimal parameter value strongly depends on the specific experimental conditions considered, ii) in 15 out of 18 conditions the errors obtained using the proposed approach and the trial-and-error were coincident, while in the other cases the maximum discrepancy amounted to 2.5 deg and less than 1.5 deg on average

    Methods and good practice guidelines for human joint kinematics estimation through magnetic and inertial wearable sensors

    Get PDF
    According to the World Health Organization, the ability to move is recognized as a key factor for the human well-being. From the wearable Magnetic and Inertial Measurement Units (MIMUs) signals it is possible to extract several digital mobility outcomes including the joint kinematics. To this end, it is first required to estimate the orientation of the MIMUs by means of a sensor fusion algorithm (SFA). After that, the relative orientation is computed and then decomposed to obtain the joint angles. However, the MIMUs do not provide a direct output of the physical quantity of interest which can be only determined after an ad hoc processing of their signals. It follows that the joint angle accuracy mostly depends on multiple factors. The first one is the magnitude of the MIMU measurements errors and up to date there is still a lack of methods for their characterization. A second crucial factor is the choice of the SFA to use. Despite the abundance of formulations in the literature, no-well established conclusions about their accuracy have been reached yet. The last factor is the biomechanical model used to compute the joint angles. In this context, unconstrained methods offer a simple way to decompose the relative orientation using the Euler angles but suffer from the inherent issues related to the SFA. In contrast, constrained approaches aim at increasing the robustness of the estimates by adopting models in which an objective function is minimized through the definition of physiological constraints. This thesis proposed the methods to accurately estimate the human joint kinematics starting from the MIMU signals. Three main contributions were provided. The first consisted in the design of a comprehensive battery of tests to completely characterize the sources of errors affecting the quality of the measurements. These tests rely on simple hypotheses based on the sensor working principles and do not require expensive equipment. Nine parameters were defined to quantify the signal accuracy improvements (if any) of 24 MIMUs before and after the refinement of their calibration coefficients. The second contribution was focused on the SFAs. Ten among the most popular SFAs were compared under different experimental conditions including different MIMU models and rotation rate magnitudes. To perform a “fair” comparison it was necessary to set the optimal parameter values for each SFA. The most important finding was that all the errors fall within a range from 3.8 deg to 7.1 deg thus making it impossible to draw any conclusions about the best performing SFA since no statistically significant differences were found. In addition, the orientation accuracy was heavily influenced by the experimental variables. After that, a novel method was designed to estimate the suboptimal parameter values of a given SFA without relying on any orientation reference. The maximum difference between the errors obtained using optimal and suboptimal parameter values amounted to 3.7 deg and to 0.6 deg on average. The last contribution consisted in the design of an unconstrained and a constrained methods for estimating the joint kinematics without considering the magnetometer to avoid the ferromagnetic disturbances. The unconstrained method was employed in a telerehabilitation platform in which the joint angles were estimated in real time. Errors collected during the execution of a full-body protocol were lower than 5 deg (considered the acceptability threshold). However, this method may be inaccurate after few minutes since no solutions can be taken to mitigate the drift error. To overcome this limitation a constrained method was developed based on a robotic model of the upper limb to set appropriate constraints. Errors relative to a continuous robot motion for twenty minutes were lower than 3 deg at most suggesting the feasibility of employing these solutions in the rehabilitation programs to properly plan the treatment and to accurately evaluate the outcomes

    Analysis of the accuracy of ten algorithms for orientation estimation using inertial and magnetic sensing under optimal conditions: One size does not fit all

    Get PDF
    The orientation of a magneto and inertial measurement unit (MIMU) is estimated by means of sensor fusion algorithms (SFAs) thus enabling human motion tracking. However, despite several SFAs implementations proposed over the last decades, there is still a lack of consensus about the best performing SFAs and their accuracy. As suggested by recent literature, the filter parameters play a central role in determining the orientation errors. The aim of this work is to analyze the accuracy of ten SFAs while running under the best possible conditions (i.e., their parameter values are set using the orientation reference) in nine experimental scenarios including three rotation rates and three commercial products. The main finding is that parameter values must be specific for each SFA according to the experimental scenario to avoid errors comparable to those obtained when the de-fault parameter values are used. Overall, when optimally tuned, no statistically significant differ-ences are observed among the different SFAs in all tested experimental scenarios and the absolute errors are included between 3.8 deg and 7.1 deg. Increasing the rotation rate generally leads to a significant performance worsening. Errors are also influenced by the MIMU commercial model. SFA MATLAB implementations have been made available online

    Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data

    Get PDF
    Upper limb tremor is the most prevalent movement disorder and, unfortunately, it is not effectively managed in a large proportion of the patients. Neuroprostheses that stimulate the sensorimotor pathways are one of the most promising alternatives although they are still under development. To enrich the interpretation of data recorded during long-term tremor monitoring and to increase the intelligence of tremor suppression neuroprostheses we need to be aware of the context. Context awareness is a major challenge for neuroprostheses and would allow these devices to react more quickly and appropriately to the changing demands of the user and/or task. Traditionally kinematic features are used to extract context information, with most recently the use of joint angles as highly potential features. In this paper we present two algorithms that enable the robust extraction of joint angle and related features to enable long-term continuous monitoring of tremor with context awareness. First, we describe a novel relative sensor placement identification technique based on orientation data. We focus on relative rather than absolute sensor location, because in many medical applications magnetic and inertial measurement units (MIMU) are used in a chain stretching over adjacent segments, or are always placed on a fixed set of locations. Subsequently we demonstrate how tremor parameters can be extracted from orientation data using an adaptive estimation algorithm. Relative sensor location was detected with an accuracy of 94.12% for the 4 MIMU configuration, and 100% for the 3 MIMU configurations. Kinematic tracking error values with an average deviation of 8% demonstrate our ability to estimate tremor from orientation data. The methods presented in this study constitute an important step toward more user-friendly and context-aware neuroprostheses for tremor suppression and monitoring

    Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data

    Get PDF
    Upper limb tremor is the most prevalent movement disorder and, unfortunately, it is not effectively managed in a large proportion of the patients. Neuroprostheses that stimulate the sensorimotor pathways are one of the most promising alternatives although they are still under development. To enrich the interpretation of data recorded during long-term tremor monitoring and to increase the intelligence of tremor suppression neuroprostheses we need to be aware of the context. Context awareness is a major challenge for neuroprostheses and would allow these devices to react more quickly and appropriately to the changing demands of the user and/or task. Traditionally kinematic features are used to extract context information, with most recently the use of joint angles as highly potential features. In this paper we present two algorithms that enable the robust extraction of joint angle and related features to enable long-term continuous monitoring of tremor with context awareness. First, we describe a novel relative sensor placement identification technique based on orientation data. We focus on relative rather than absolute sensor location, because in many medical applications magnetic and inertial measurement units (MIMU) are used in a chain stretching over adjacent segments, or are always placed on a fixed set of locations. Subsequently we demonstrate how tremor parameters can be extracted from orientation data using an adaptive estimation algorithm. Relative sensor location was detected with an accuracy of 94.12% for the 4 MIMU configuration, and 100% for the 3 MIMU configurations. Kinematic tracking error values with an average deviation of 8% demonstrate our ability to estimate tremor from orientation data. The methods presented in this study constitute an important step toward more user-friendly and context-aware neuroprostheses for tremor suppression and monitoring. © 2014 Lambrecht, Gallego, Rocon and Pons.This work has been funded by the European project NeuroTremor(ICT-2011.5.1-287739)andt he Spanish Consolider project HYPER (CSD2009-00067).Peer Reviewe

    A Narrative Review on Wearable Inertial Sensors for Human Motion Tracking in Industrial Scenarios

    Get PDF
    Industry 4.0 has promoted the concept of automation, supporting workers with robots while maintaining their central role in the factory. To guarantee the safety of operators and improve the effectiveness of the human-robot interaction, it is important to detect the movements of the workers. Wearable inertial sensors represent a suitable technology to pursue this goal because of their portability, low cost, and minimal invasiveness. The aim of this narrative review was to analyze the state-of-the-art literature exploiting inertial sensors to track the human motion in different industrial scenarios. The Scopus database was queried, and 54 articles were selected. Some important aspects were identified: (i) number of publications per year; (ii) aim of the studies; (iii) body district involved in the motion tracking; (iv) number of adopted inertial sensors; (v) presence/absence of a technology combined to the inertial sensors; (vi) a real-time analysis; (vii) the inclusion/exclusion of the magnetometer in the sensor fusion process. Moreover, an analysis and a discussion of these aspects was also developed

    Gait characterization using wearable inertial sensors in healthy and pathological populations

    Get PDF
    Gait analysis is emerging as an effective tool to detect an incipient neurodegenerative disease or to monitor its progression. It has been shown that gait disturbances are an early indicator for cognitive impairments and can predict progression to neurodegenerative diseases. Furthermore, gait performance is a predictor of fall status, morbidity and mortality. Instrumented gait analysis provides quantitative measures to support the investigation of gait pathologies and the definition of targeted rehabilitation programs. In this framework, technologies such as inertial sensors are well accepted, and increasingly employed, as tools to characterize locomotion patterns and their variability in research settings. The general aim of this thesis is the evaluation, comparison and refinement of methods for gait characterization using magneto-inertial measurement units (MIMUs), in order to contribute to the migration of instrumented gait analysis from state of the art to state of the science (i.e.: from research towards its application in standard clinical practice). At first, methods for the estimation of spatio-temporal parameters during straight gait were investigated. Such parameters are in fact generally recognized as key metrics for an objective evaluation of gait and a quantitative assessment of clinical outcomes. Although several methods for their estimate have been proposed, few provided a thorough validation. Therefore an error analysis across different pathologies, multiple clinical centers and large sample size was conducted to further validate a previously presented method (TEADRIP). Results confirmed the applicability and robustness of the TEADRIP method. The combination of good performance, reliability and range of usage indicate that the TEADRIP method can be effectively adopted for gait spatio-temporal parameter estimation in the routine clinical practice. However, while traditionally gait analysis is applied to straight walking, several clinical motor tests include turns between straight gait segments. Furthermore, turning is used to evaluate subjects’ motor ability in more challenging circumstances. The second part of the research therefore headed towards the application of gait analysis on turning, both to segment it (i.e.: distinguish turns and straight walking bouts) and to specifically characterize it. Methods for turn identification based on a single MIMU attached to the trunk were implemented and their performance across pathological populations was evaluated. Focusing on Parkinson’s Disease (PD) subjects, turn characterization was also addressed in terms of onset and duration, using MIMUs positioned both on the trunk and on the ankles. Results showed that in PD population turn characterization with the sensors at the ankles lacks of precision, but that a single MIMU positioned on the low back is functional for turn identification. The development and validation of the methods considered in these works allowed for their application to clinical studies, in particular supporting the spatio-temporal parameters analysis in a PD treatment assessment and the investigation of turning characteristic in PD subjects with Freezing of Gait. In the first application, comparing the pre and post parameters it was possible to objectively determine the effectiveness of a rehabilitation treatment. In the second application, quantitative measures confirmed that in PD subjects with Freezing of Gait turning 360° in place is further compromised (and requires additional cognitive effort) compared to turning 180° while walking

    Wearable inertial sensors for human movement analysis

    Get PDF
    Introduction: The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis.Areas covered: Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-life activity monitoring and tremor assessment. Each area is analyzed both from a methodological and applicative point of view. The focus on the methodological approaches is meant to provide an idea of the computational complexity behind a variable/parameter/index of interest so that the reader is aware of the reliability of the approach. The focus on the application is meant to provide a practical guide for advising clinicians on how inertial sensors can help them in their clinical practice.Expert commentary: Less expensive and more easy to use than other systems used in human movement analysis, wearable sensors have evolved to the point that they can be considered ready for being part of routine clinical routine
    corecore