840 research outputs found

    Tactile-STAR: A Novel Tactile STimulator And Recorder System for Evaluating and Improving Tactile Perception

    Get PDF
    Many neurological diseases impair the motor and somatosensory systems. While several different technologies are used in clinical practice to assess and improve motor functions, somatosensation is evaluated subjectively with qualitative clinical scales. Treatment of somatosensory deficits has received limited attention. To bridge the gap between the assessment and training of motor vs. somatosensory abilities, we designed, developed, and tested a novel, low-cost, two-component (bimanual) mechatronic system targeting tactile somatosensation: the Tactile-STAR—a tactile stimulator and recorder. The stimulator is an actuated pantograph structure driven by two servomotors, with an end-effector covered by a rubber material that can apply two different types of skin stimulation: brush and stretch. The stimulator has a modular design, and can be used to test the tactile perception in different parts of the body such as the hand, arm, leg, big toe, etc. The recorder is a passive pantograph that can measure hand motion using two potentiometers. The recorder can serve multiple purposes: participants can move its handle to match the direction and amplitude of the tactile stimulator, or they can use it as a master manipulator to control the tactile stimulator as a slave. Our ultimate goal is to assess and affect tactile acuity and somatosensory deficits. To demonstrate the feasibility of our novel system, we tested the Tactile-STAR with 16 healthy individuals and with three stroke survivors using the skin-brush stimulation. We verified that the system enables the mapping of tactile perception on the hand in both populations. We also tested the extent to which 30 min of training in healthy individuals led to an improvement of tactile perception. The results provide a first demonstration of the ability of this new system to characterize tactile perception in healthy individuals, as well as a quantification of the magnitude and pattern of tactile impairment in a small cohort of stroke survivors. The finding that short-term training with Tactile-STARcan improve the acuity of tactile perception in healthy individuals suggests that Tactile-STAR may have utility as a therapeutic intervention for somatosensory deficits

    Tactile feedback display with spatial and temporal resolutions.

    Get PDF
    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications

    Tactile-STAR: A novel tactile STimulator And Recorder system for evaluating and improving tactile perception

    Get PDF
    Many neurological diseases impair the motor and somatosensory systems. While several different technologies are used in clinical practice to assess and improve motor functions, somatosensation is evaluated subjectively with qualitative clinical scales. Treatment of somatosensory deficits has received limited attention. To bridge the gap between the assessment and training of motor vs. somatosensory abilities, we designed, developed, and tested a novel, low-cost, two-component (bimanual) mechatronic system targeting tactile somatosensation: the Tactile-STAR\u2014a tactile stimulator and recorder. The stimulator is an actuated pantograph structure driven by two servomotors, with an end-effector covered by a rubber material that can apply two different types of skin stimulation: brush and stretch. The stimulator has a modular design, and can be used to test the tactile perception in different parts of the body such as the hand, arm, leg, big toe, etc. The recorder is a passive pantograph that can measure hand motion using two potentiometers. The recorder can serve multiple purposes: participants can move its handle to match the direction and amplitude of the tactile stimulator, or they can use it as a master manipulator to control the tactile stimulator as a slave. Our ultimate goal is to assess and affect tactile acuity and somatosensory deficits. To demonstrate the feasibility of our novel system, we tested the Tactile-STAR with 16 healthy individuals and with three stroke survivors using the skin-brush stimulation. We verified that the system enables the mapping of tactile perception on the hand in both populations. We also tested the extent to which 30 min of training in healthy individuals led to an improvement of tactile perception. The results provide a first demonstration of the ability of this new system to characterize tactile perception in healthy individuals, as well as a quantification of the magnitude and pattern of tactile impairment in a small cohort of stroke survivors. The finding that short-term training with Tactile-STAR can improve the acuity of tactile perception in healthy individuals suggests that Tactile-STAR may have utility as a therapeutic intervention for somatosensory deficits

    Electrotactile feedback applications for hand and arm interactions: A systematic review, meta-analysis, and future directions

    Get PDF
    Haptic feedback is critical in a broad range of human-machine/computer-interaction applications. However, the high cost and low portability/wearability of haptic devices remain unresolved issues, severely limiting the adoption of this otherwise promising technology. Electrotactile interfaces have the advantage of being more portable and wearable due to their reduced actuators' size, as well as their lower power consumption and manufacturing cost. The applications of electrotactile feedback have been explored in human-computer interaction and human-machine-interaction for facilitating hand-based interactions in applications such as prosthetics, virtual reality, robotic teleoperation, surface haptics, portable devices, and rehabilitation. This paper presents a technological overview of electrotactile feedback, as well a systematic review and meta-analysis of its applications for hand-based interactions. We discuss the different electrotactile systems according to the type of application. We also discuss over a quantitative congregation of the findings, to offer a high-level overview into the state-of-art and suggest future directions. Electrotactile feedback systems showed increased portability/wearability, and they were successful in rendering and/or augmenting most tactile sensations, eliciting perceptual processes, and improving performance in many scenarios. However, knowledge gaps (e.g., embodiment), technical (e.g., recurrent calibration, electrodes' durability) and methodological (e.g., sample size) drawbacks were detected, which should be addressed in future studies.Comment: 18 pages, 1 table, 8 figures, under review in Transactions on Haptics. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.Upon acceptance of the article by IEEE, the preprint article will be replaced with the accepted versio

    Preliminary design of a multi-touch ultrasonic tactile stimulator

    Get PDF
    This paper presents a method to control ultrasonic waves on a beam, allowing to obtain a Multi-touch ultrasonic tactile stimulation in two points, to give the sensation to two fingers, from two piezoelectric transducers. The multi-modal approach and the vector control method are used to regulate the vibration amplitude, in order to modulate the friction coefficient with the fingers. An analytical modelling is presented, with experimental validation. Finally a psychophysical experiment shows that a multi-touch ultrasonic tactile stimulation is possible.This work has been carried out within the framework of the project StimTac of IRCICA (institut de recherche sur les composants logiciels et matériel pour la communication avancée), and the Project Mint of Inria

    The Impact of Stimulation Intensity on Spatial Discrimination with Multi-Pad Finger Electrode

    Get PDF
    Multi-pad electrotactile stimulation can be used to provide tactile feedback in different applications. The electrotactile interface needs to be calibrated before each use, which entails adjusting the intensity to obtain clear sensations while allowing the subjects to differentiate between active pads. The present study investigated how the stimulation intensity affects the localization of sensations using a multi-pad electrode placed on a fingertip and proximal phalange. First, the sensation, localization, smearing and discomfort thresholds were determined in 11 subjects. Then, the same subjects performed a spatial discrimination test across a range of stimulation intensities. The results have shown that all thresholds were significantly different, while there was no difference in the threshold values between the pads and phalanges. Despite the subjective feeling of spreading of sensations, the success rates in spatial discrimination were not significantly different across the tested stimulation intensities. However, the performance was better for distal compared to proximal phalange. Presented results indicate that spatial discrimination is robust to changes in the stimulation intensity. Considering the lack of significant difference in the thresholds between the pads, these results imply that more coarse adjustment of stimulation amplitude (faster calibration) might be enough for practical applications of a multi-pad electrotactile interface.This research was funded by the TACTILITY project, which has received funding by European Union’s Horizon 2020 framework programme for research and innovation H2020-ICT 2018-2020/H2020-ICT-2018-3 under grant agreement no. 856718

    Integrating Sensory Feedback into a Neural Bypass Device

    Get PDF
    Kirmser Undergraduate Research Award - Individual Non-Freshman category, grand prizeRoger FriedmannThe objective of the project was to identify a problem or opportunity with a company process or product and propose a change based on thorough research. For my project, I chose the NeuroLife neural bypass device produced by Battelle. The device was designed to provide hundreds of thousands of people with the opportunity to overcome devastating neurological damage and disorders. However, the current design focuses only on restoring motor function. As a result, the patient faces challenges and limitations when moving a limb due to lack of immediate feedback to the brain to inform subsequent movements. My proposed change was to integrate sensory information to build a bidirectional neural bypass device to improve patient usability and device performance. Therefore, I investigated three primary cortical stimulation techniques being researched and developed for restoring sensory feedback. I also evaluated each technique based on prominent challenges that accompany brain-computer interfaces (BCIs). The three main methods for stimulating the central nervous system include magnetic stimulation, optogenetics, and electrical stimulation. The areas I used to evaluate each method were tissue damage, specificity of neuronal excitement, ethical considerations, and types of sensory information that have been successfully restored. Based on my research and the evaluation criteria, I propose integrating electrical stimulation into a neural bypass device because it would be the most feasible and reliable. I also provide recommendations for Battelle as possible steps for implementing my proposal

    A tactile paging system for deaf-blind people, phase 2

    Get PDF
    Control logic and the on-body radio transmitter is investigated. The control logic capability and studied methods for implementing the on-body portion of the logic in a small package are improved. A small low power, on-body transmitter was designed, developed, and tested with a wrist-strap antenna to extend the one-way communication system developed during Phase 1 to a two-way communication system
    • …
    corecore