66 research outputs found

    Development of An In Vivo Robotic Camera for Dexterous Manipulation and Clear Imaging

    Get PDF
    Minimally invasive surgeriy (MIS) techniques are becoming more popular as replacements for traditional open surgeries. These methods benefit patients with lowering blood loss and post-operative pain, reducing recovery period and hospital stay time, decreasing surgical area scarring and cosmetic issues, and lessening the treatment costs, hence greater patient satisfaction would be earned. Manipulating surgical instruments from outside of abdomen and performing surgery needs precise hand-eye coordination which is provided by insertable cameras. The traditional MIS insertable cameras suffer from port complexity and reduced manipulation dexterity, which leads to defection in Hand-eye coordination and surgical flow. Fully insertable robotic camera systems emerged as a promising solution in MIS. Implementing robotic camera systems faces multiple challenges in fixation, manipulation, orientation control, tool-tissue interaction, in vivo illumination and clear imaging.In this dissertation a novel actuation and control mechanism is developed and validated for an insertable laparoscopic camera. This design uses permanent magnets and coils as force/torque generators in an external control unit to manipulate an in vivo camera capsule. The motorless design of this capsule reduces the, wight, size and power consumption of the driven unit. In order to guarantee the smooth motion of the camera inside the abdominal cavity, an interaction force control method was proposed and validated.Optimizing the system\u27s design, through minimizing the control unit size and power consumption and extending maneuverability of insertable camera, was achieved by a novel transformable design, which uses a single permanent magnet in the control unit. The camera robot uses a permanent magnet as fixation and translation unit, and two embedded motor for tilt motion actuation, as well as illumination actuation. Transformable design provides superior imaging quality through an optimized illumination unit and a cleaning module. The illumination module uses freeform optical lenses to control light beams from the LEDs to achieve optimized illumination over surgical zone. The cleaning module prevents lens contamination through a pump actuated debris prevention system, while mechanically wipes the lens in case of contamination. The performance of transformable design and its modules have been assessed experimentally

    A Magnetic Actuated Fully Insertable Robotic Camera System for Single Incision Laparoscopic Surgery

    Get PDF
    Minimally Invasive Surgery (MIS) is a common surgical procedure which makes tiny incisions in the patients anatomy, inserting surgical instruments and using laparoscopic cameras to guide the procedure. Compared with traditional open surgery, MIS allows surgeons to perform complex surgeries with reduced trauma to the muscles and soft tissues, less intraoperative hemorrhaging and postoperative pain, and faster recovery time. Surgeons rely heavily on laparoscopic cameras for hand-eye coordination and control during a procedure. However, the use of a standard laparoscopic camera, achieved by pushing long sticks into a dedicated small opening, involves multiple incisions for the surgical instruments. Recently, single incision laparoscopic surgery (SILS) and natural orifice translumenal endoscopic surgery (NOTES) have been introduced to reduce or even eliminate the number of incisions. However, the shared use of a single incision or a natural orifice for both surgical instruments and laparoscopic cameras further reduces dexterity in manipulating instruments and laparoscopic cameras with low efficient visual feedback. In this dissertation, an innovative actuation mechanism design is proposed for laparoscopic cameras that can be navigated, anchored and orientated wirelessly with a single rigid body to improve surgical procedures, especially for SILS. This design eliminates the need for an articulated design and the integrated motors to significantly reduce the size of the camera. The design features a unified mechanism for anchoring, navigating, and rotating a fully insertable camera by externally generated rotational magnetic field. The key component and innovation of the robotic camera is the magnetic driving unit, which is referred to as a rotor, driven externally by a specially designed magnetic stator. The rotor, with permanent magnets (PMs) embedded in a capsulated camera, can be magnetically coupled to a stator placed externally against or close to a dermal surface. The external stator, which consists of PMs and coils, generates 3D rotational magnetic field that thereby produces torque to rotate the rotor for desired camera orientation, and force to serve as an anchoring system that keeps the camera steady during a surgical procedure. Experimental assessments have been implemented to evaluate the performance of the camera system

    Magnetic Surgical Instruments for Robotic Abdominal Surgery.

    Get PDF
    This review looks at the implementation of magnetic-based approaches in surgical instruments for abdominal surgeries. As abdominal surgical techniques advance toward minimizing surgical trauma, surgical instruments are enhanced to support such an objective through the exploration of magnetic-based systems. With this design approach, surgical devices are given the capabilities to be fully inserted intraabdominally to achieve access to all abdominal quadrants, without the conventional rigid link connection with the external unit. The variety of intraabdominal surgical devices are anchored, guided, and actuated by external units, with power and torque transmitted across the abdominal wall through magnetic linkage. This addresses many constraints encountered by conventional laparoscopic tools, such as loss of triangulation, fulcrum effect, and loss/lack of dexterity for surgical tasks. Design requirements of clinical considerations to aid the successful development of magnetic surgical instruments, are also discussed

    Development of A Soft Robotic Approach for An Intra-abdominal Wireless Laparoscopic Camera

    Get PDF
    In Single-Incision Laparoscopic Surgery (SILS), the Magnetic Anchoring and Guidance System (MAGS) arises as a promising technique to provide larger workspaces and field of vision for the laparoscopes, relief space for other instruments, and require fewer incisions. Inspired by MAGS, many concept designs related to fully insertable magnetically driven laparoscopes are developed and tested on the transabdominal operation. However, ignoring the tissue interaction and insertion procedure, most of the designs adopt rigid structures, which not only damage the patients\u27 tissue with excess stress concentration and sliding motion but also require complicated operation for the insertion. Meanwhile, lacking state tracking of the insertable camera including pose and contact force, the camera systems operate in open-loop control. This provides mediocre locomotion precision and limited robustness to uncertainties in the environment. This dissertation proposes, develops, and validates a soft robotic approach for an intra-abdominal wireless laparoscopic camera. Contributions presented in this work include (1) feasibility of a soft intra-abdominal laparoscopic camera with friendly tissue interaction and convenient insertion, (2) six degrees of freedom (DOF) real-time localization, (3) Closed-loop control for a robotic-assisted laparoscopic system and (4) untethering solution for wireless communication and high-quality video transmission. Embedding magnet pairs into the camera and external actuator, the camera can be steered and anchored along the abdominal wall through transabdominal magnetic coupling. To avoid the tissue rapture by the sliding motion and dry friction, a wheel structure is applied to achieve rolling motion. Borrowing the ideas from soft robotic research, the main body of the camera implements silicone material, which grants it the bendability to passively attach along the curved abdominal wall and the deformability for easier insertion. The six-DOF pose is estimated in real-time with internal multi-sensor fusion and Newton-Raphson iteration. Combining the pose tracking and force-torque sensor measurement, an interaction model between the deformable camera and tissue is established to evaluate the interaction force over the tissue surface. Moreover, the proposed laparoscopic system is integrated with a multi-DOF manipulator into a robotic-assisted surgical system, where a closed-loop control is realized based on a feedback controller and online optimization. Finally, the wireless control and video streaming are accomplished with Bluetooth Low Energy (BLE) and Analog Video (AV) transmission. Experimental assessments have been implemented to evaluate the performance of the laparoscopic system

    sCAM: An Untethered Insertable Laparoscopic Surgical Camera Robot

    Get PDF
    Fully insertable robotic imaging devices represent a promising future of minimally invasive laparoscopic vision. Emerging research efforts in this field have resulted in several proof-of-concept prototypes. One common drawback of these designs derives from their clumsy tethering wires which not only cause operational interference but also reduce camera mobility. Meanwhile, these insertable laparoscopic cameras are manipulated without any pose information or haptic feedback, which results in open loop motion control and raises concerns about surgical safety caused by inappropriate use of force.This dissertation proposes, implements, and validates an untethered insertable laparoscopic surgical camera (sCAM) robot. Contributions presented in this work include: (1) feasibility of an untethered fully insertable laparoscopic surgical camera, (2) camera-tissue interaction characterization and force sensing, (3) pose estimation, visualization, and feedback with sCAM, and (4) robotic-assisted closed-loop laparoscopic camera control. Borrowing the principle of spherical motors, camera anchoring and actuation are achieved through transabdominal magnetic coupling in a stator-rotor manner. To avoid the tethering wires, laparoscopic vision and control communication are realized with dedicated wireless links based on onboard power. A non-invasive indirect approach is proposed to provide real-time camera-tissue interaction force measurement, which, assisted by camera-tissue interaction modeling, predicts stress distribution over the tissue surface. Meanwhile, the camera pose is remotely estimated and visualized using complementary filtering based on onboard motion sensing. Facilitated by the force measurement and pose estimation, robotic-assisted closed-loop control has been realized in a double-loop control scheme with shared autonomy between surgeons and the robotic controller.The sCAM has brought robotic laparoscopic imaging one step further toward less invasiveness and more dexterity. Initial ex vivo test results have verified functions of the implemented sCAM design and the proposed force measurement and pose estimation approaches, demonstrating the technical feasibility of a tetherless insertable laparoscopic camera. Robotic-assisted control has shown its potential to free surgeons from low-level intricate camera manipulation workload and improve precision and intuitiveness in laparoscopic imaging

    Snake-Like Robots for Minimally Invasive, Single Port, and Intraluminal Surgeries

    Full text link
    The surgical paradigm of Minimally Invasive Surgery (MIS) has been a key driver to the adoption of robotic surgical assistance. Progress in the last three decades has led to a gradual transition from manual laparoscopic surgery with rigid instruments to robot-assisted surgery. In the last decade, the increasing demand for new surgical paradigms to enable access into the anatomy without skin incision (intraluminal surgery) or with a single skin incision (Single Port Access surgery - SPA) has led researchers to investigate snake-like flexible surgical devices. In this chapter, we first present an overview of the background, motivation, and taxonomy of MIS and its newer derivatives. Challenges of MIS and its newer derivatives (SPA and intraluminal surgery) are outlined along with the architectures of new snake-like robots meeting these challenges. We also examine the commercial and research surgical platforms developed over the years, to address the specific functional requirements and constraints imposed by operations in confined spaces. The chapter concludes with an evaluation of open problems in surgical robotics for intraluminal and SPA, and a look at future trends in surgical robot design that could potentially address these unmet needs.Comment: 41 pages, 18 figures. Preprint of article published in the Encyclopedia of Medical Robotics 2018, World Scientific Publishing Company www.worldscientific.com/doi/abs/10.1142/9789813232266_000

    METHODS, SYSTEMS, AND DEVICES FOR SURGICAL ACCESS AND PROCEDURES

    Get PDF
    The embodiments disclosed herein relate to various medical device components, including components that can be incorporated into robotic and/or in vivo medical devices. Certain embodiments include various actuation system embodiments, including fluid actuation systems, drive train actuation systems, and motorless actuation systems. Additional embodiments include a reversibly lockable tube that can provide access for a medical device to a patient\u27s cavity and further provides a reversible rigidity or stability during operation of the device. Further embodiments include various operational components for medical devices, including medical device arm mechanisms that have both axial and rotational movement while maintaining a relatively compact structure. medical device winch components, medical device biopsy/stapler/clamp mechanisms, and medical device adjustable focus mechanisms
    corecore