144 research outputs found

    3D Modelling and design of a bioloid compliant quadruped leg

    Get PDF
    Dissertação de mestrado integrado em Engenharia BiomédicaIn the growing fields of rehabilitation robotics, prosthetics, and walking robots, the modeling of a real robot is a complex and passionate challenge. On the crossing point of mechanics, physics and computer-science, the development of a complete model involves multiple tasks ranging from the 3D modeling of the different body parts, the measure of the different physic properties, the understanding of the requirements for an accurate simulation, to the development of a robotic controller. In order to minimize large forces due to shocks, to safely interact with the user or the environment, and knowing the ability of passive elastic elements to store and release energy, compliant mechanisms are increasingly being applied in robots applications. This work aims to the elaboration of an accurate efficient three-dimensional model of the legs of the quadruped Bioloid robot and the development of a world showing the effect on WebotsTM simulation software developed by Cyberbotics Ltd. The goal was to design a segmented pantographic leg with compliant joints, in order to actively retract the collision and the impact of the quadruped legs with the ground during locomotion. Geometrical and mechanical limits have to be evaluated and considered for the modeling setup. Finally a controller based on the use of Central Pattern Generators was improved in order to adapt to the novel model and simple tests were performed in the WebotsTM, rendering a 3D model simulation for the different values of spring-damping coefficients at the legs knee joint. Through the a MATLAB® algorithm, the characterization of the joint angles during simulation was possible to be assessed.A modelação de um robot real é um desafio complexo e fascinante na crescente área da Robótica, que engloba desde robots de reabilitação, próteses a uma diversidade de outros dispositivos locomotores. No cruzamento da mecânica com a física e as ciências computacionais, o desenvolvimento de um modelo completo envolve várias tarefas que vão desde a modelação 3D das diferentes partes do corpo, a medição das propriedades físicos inerentes, a compreensão dos requisitos para uma simulação precisa bem como a aplicação de um controlador robótico. A fim de minimizar grandes forças devido a choques, interagir com segurança com o utilizador ou o ambiente e conhecendo a capacidade de armazenagem de energia por parte de elementos elásticos passivos, um sistema de amortecimento-mola demonstra ser uma aplicação de crescente interesse na Robótica. Este trabalho visa a elaboração de um modelo tridimensional eficiente e preciso das pernas do robô quadrúpede Bioloid a ser reproduzido num mundo no software WebotsTM desenvolvido pela Cyberbotics Ltd. O objectivo foi desenhar uma perna pantográfica segmentada tridimensional a ser aplicada em paralelo com um sistema de amortecimento-mola de forma a retrair activamente a colisão e o impacto das patas do quadrúpede com o solo durante a locomoção. Deste modo para uma configuração do modelo bem sucedida são tidos em conta limites geométricos e mecânicos. Por ultimo, o controlador com base no uso de ‘Central Pattern Generators’ foi melhorado a fim de se adaptar ao novo modelo e por conseguinte foram realizados testes simples usando o simulador WebotsTM. Nesta parte experimental é realizada a simulação do modelo permitindo avaliar o comportamento do modelo 3D para diferentes valores de coeficientes de mola e de amortecimento aplicados a nível do joelho da perna. Através de um algoritmo MATLAB® é possível caracterizar e analisar o comportamento doa ângulos das juntas durante a simulação

    Simulating a Flexible Robotic System based on Musculoskeletal Modeling

    Get PDF
    Humanoid robotics offers a unique research tool for understanding the human brain and body. The synthesis of human motion is a complex procedure that involves accurate reconstruction of movement sequences, modeling of musculoskeletal kinematics, dynamics and actuation, and characterization of reliable performance criteria. Many of these processes have much in common with the problems found in robotics research, with the recent advent of complex humanoid systems. This work presents the design and development of a new-generation bipedal robot. Its modeling and simulation has been realized by using an open-source software to create and analyze dynamic simulation of movement: OpenSim. Starting from a study by Fuben He, our model aims to be used as an innovative approach to the study of a such type of robot in which there are series elastic actuators represented by active and passive spring components in series with motors. It has provided of monoarticular and biarticular joint in a very similar manner to human musculoskeletal model. This thesis is only the starting point of a wide range of other possible future works: from the control structure completion and whole-body control application, to imitation learning and reinforcement learning for human locomotion, from motion test on at ground to motion test on rough ground, and obviously the transition from simulation to practice with a real elastic bipedal robot biologically-inspired that can move like a human bein

    Legged robotic locomotion with variable impedance joints

    Get PDF
    Humans have a complex musculoskeletal arrangement which gives them great behavioural flexibility. As well as simply moving their legs, they can modulate the impedance of them. Variable impedance has become a large field in robotics, and tailoring the impedance of a robot to a particular task can improve efficiency, stability, and potentially safety. Locomotion of a bipedal robot is a perfect example of a task for which variable impedance may provide such advantages, since it is a dynamic movement which involves periodic ground impacts. This thesis explores the creation of two novel bipedal robots with variable impedance joints. These robots aim to achieve some of the benefits of compliance, while retaining the behavioural flexibility to be truly versatile machines. The field of variable impedance actuators is explored and evaluated, before the design of the robots is presented. Of the two robots, BLUE (Bipedal Locomotion at the University of Edinburgh) has a 700mm hip rotation height, and is a saggital plane biped. miniBLUE has a hip rotation height of 465mm, and includes additional joints to allow hip adduction and abduction. Rapid prototyping techniques were utilised in the creation of both robots, and both robots are based around a custom, high performance electronics and communication architecture. The human walking cycle is analysed and a simple, parameterised representation developed. Walking trajectories gathered from human motion capture data, and generated from high level gait determinants are evaluated in dynamic simulation, and then on BLUE. With the robot being capable of locomotion, we explore the effect of varying stiffness on efficiency, and find that changing the stiffness can have an effect on the energy efficiency of the movement. Finally, we introduce a system for goal-based teleoperation of the robots, in which parameters are extracted from a user in a motion capture suit and replicated by the robot. In this way, the robot produces the same overall locomotion as the human, but with joint trajectories and stiffnesses that are more suited for its dynamics

    Advancing Musculoskeletal Robot Design for Dynamic and Energy-Efficient Bipedal Locomotion

    Get PDF
    Achieving bipedal robot locomotion performance that approaches human performance is a challenging research topic in the field of humanoid robotics, requiring interdisciplinary expertise from various disciplines, including neuroscience and biomechanics. Despite the remarkable results demonstrated by current humanoid robots---they can walk, stand, turn, climb stairs, carry a load, push a cart---the versatility, stability, and energy efficiency of humans have not yet been achieved. However, with robots entering our lives, whether in the workplace, in clinics, or in normal household environments, such improvements are increasingly important. The current state of research in bipedal robot locomotion reveals that several groups have continuously demonstrated enhanced locomotion performance of the developed robots. But each of these groups has taken a unilateral approach and placed the focus on only one aspect, in order to achieve enhanced movement abilities;---for instance, the motion control and postural stability or the mechanical design. The neural and mechanical systems in human and animal locomotion, however, are strongly coupled and should therefore not be treated separately. Human-inspired musculoskeletal design of bipedal robots offers great potential for enhanced dynamic and energy-efficient locomotion but also imposes major challenges for motion planning and control. In this thesis, we first present a detailed review of the problems related to achieving enhanced dynamic and energy-efficient bipedal locomotion, from various important perspectives, and examine the essential properties of the human locomotory apparatus. Subsequently, existing insights and approaches from biomechanics, to understand the neuromechanical motion apparatus, and from robotics, to develop more human-like robots that can move in our environment, are discussed in detail. These thorough investigations of the interrelated essential design decisions are used to develop a novel design for a musculoskeletal bipedal robot, BioBiped1, such that, in the long term, it is capable of realizing dynamic hopping, running, and walking motions. The BioBiped1 robot features a highly compliant tendon-driven actuation system that mimics key functionalities of the human lower limb system. In experiments, BioBiped1's locomotor function for the envisioned gaits is validated globally. It is shown that the robot is able to rebound passively, store and release energy, and actively push off from the ground. The proof of concept of BioBiped1's locomotor function, however, marks only the starting point for our investigations, since this novel design concept opens up a number of questions regarding the required design complexity for the envisioned motions and the appropriate motion generation and control concept. For this purpose, a simulator specifically designed for the requirements of musculoskeletally actuated robotic systems, including sufficiently realistic ground reaction forces, is developed. It relies on object-oriented design and is based on a numerical solver, without model switching, to enable the analysis of impact peak forces and the simulation of flight phases. The developed library also contains the models of the actuated and passive mono- and biarticular elastic tendons and a penalty-based compliant contact model with nonlinear damping, to incorporate the collision, friction, and stiction forces occurring during ground contact. Using these components, the full multibody system (MBS) dynamics model is developed. To ensure a sufficiently similar behavior of the simulated and the real musculoskeletal robot, various measurements and parameter identifications for sub-models are performed. Finally, it is shown that the simulation model behaves similarly to the real robot platform. The intelligent combination of actuated and passive mono- and biarticular tendons, imitating important human muscle groups, offers tremendous potential for improved locomotion performance but also requires a sophisticated concept for motion control of the robot. Therefore, a further contribution of this thesis is the development of a centralized, nonlinear model-based method for motion generation and control that utilizes the derived detailed dynamics models of the implemented actuators. The concept is used to realize both computer-generated hopping and human jogging motions. Additionally, the problem of appropriate motor-gear unit selection prior to the robot's construction is tackled, using this method. The thesis concludes with a number of simulation studies in which several leg actuation designs are examined for their optimality with regard to systematically selected performance criteria. Furthermore, earlier paradoxical biomechanical findings about biarticular muscles in running are presented and, for the first time, investigated by detailed simulation of the motion dynamics. Exploring the Lombard paradox, a novel reduced and energy-efficient locomotion model without knee extensor has been simulated successfully. The models and methods developed within this thesis, as well as the insights gained, are already being employed to develop future prototypes. In particular, the optimal dimensioning and setting of the actuators, including all mono- and biarticular muscle-tendon units, are based on the derived design guidelines and are extensively validated by means of the simulation models and the motion control method. These developments are expected to significantly enhance progress in the field of bipedal robot design and, in the long term, to drive improvements in rehabilitation for humans through an understanding of the neuromechanics underlying human walking and the application of this knowledge to the design of prosthetics

    Consider the robot - Abstraction of bioinspired leg coordination and its application to a hexapod robot under consideration of technical constraints

    Get PDF
    Paskarbeit J. Consider the robot - Abstraction of bioinspired leg coordination and its application to a hexapod robot under consideration of technical constraints. Bielefeld: Universität Bielefeld; 2017.To emulate the movement agility and adaptiveness of stick insects in technical systems such as piezo actuators (Szufnarowski et al. 2014) or hexapod robots (Schneider, Cruse et al. 2006), a direct adaptation of bioinspired walking controllers like WALKNET has often been suggested. However, stick insects have very specific features such as adhesive foot pads that allow them to cling to the ground. Typically, robots do not possess such features. Besides, robots tend to be bigger and heavier than their biological models, usually possessing a different mass distribution as well. This leads to different mechanical and functional properties that need to be addressed in control. Based on the model of the stick insect *Carausius morosus*, the six-legged robot HECTOR was developed in this work to test and evaluate bioinspired controllers. The robot's geometrical layout corresponds to that of the stick insect, scaled up by a factor of 20. Moreover, like the stick insect, the robot features an inherent compliance in its joints. This compliance facilitates walking in uneven terrain since small irregularities can be compensated passively without controller intervention. However, the robot differs from the biological model, e.g., in terms of its size, mass, and mass distribution. Also, it does not possess any means to cling to the ground and therefore must maintain static stability to avoid tilting. To evaluate the ability of stick insects to maintain static stability, experimental data (published by Theunissen et al. (2014)) was examined. It can be shown that stick insects do not maintain static stability at all times. Still, due to their adhesive foot pads, they do not tumble. Therefore, a direct replication of the biological walking controller would not be suitable for the control of HECTOR. In a next step, the bioinspired walking controller WALKNET (Cruse, Kindermann, et al. 1998) was evaluated regarding its applicability for the control of HECTOR. For this purpose, different parametrizations of WALKNET were tested in a simulation environment. For forward walking, parameter sets were found that achieve a high, although not permanent stability. Thus, for the control of HECTOR, which requires continuous stability, a more abstract adaption of the bioinspired coordination had to be found. Based on the original coordination concepts of WALKNET, new coordination mechanisms were developed that incorporate the technical requirements (static stability, angular joint limits, torque constraints, etc.). The ability of the resulting controller to generate insect-like gaits is demonstrated for different walking scenarios in simulation. Moreover, locomotion that is unlikely for insects such as backwards and sidewards walking is shown to be feasible using the novel control approach. At the end of this work the applicability of the approach for the control of the real robot is proved in experiments on visual collision avoidance and basic climbing ability

    NASA Tech Briefs, September 2012

    Get PDF
    Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load

    A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation

    Get PDF
    The application of laser technologies in surgical interventions has been accepted in the clinical domain due to their atraumatic properties. In addition to manual application of fibre-guided lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours has been prevailed in ENT surgery. However, TLM requires many years of surgical training for tumour resection in order to preserve the function of adjacent organs and thus preserve the patient’s quality of life. The positioning of the microscopic laser applicator outside the patient can also impede a direct line-of-sight to the target area due to anatomical variability and limit the working space. Further clinical challenges include positioning the laser focus on the tissue surface, imaging, planning and performing laser ablation, and motion of the target area during surgery. This dissertation aims to address the limitations of TLM through robotic approaches and intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no highly integrated platform for endoscopic delivery of focused laser radiation is available to date. Likewise, there are no known devices that incorporate scene information from endoscopic imaging into ablation planning and execution. For focusing of the laser beam close to the target tissue, this work first presents miniaturised focusing optics that can be integrated into endoscopic systems. Experimental trials characterise the optical properties and the ablation performance. A robotic platform is realised for manipulation of the focusing optics. This is based on a variable-length continuum manipulator. The latter enables movements of the endoscopic end effector in five degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the robot are integrated into a modular framework that is evaluated experimentally. The manipulation of focused laser radiation also requires precise adjustment of the focal position on the tissue. For this purpose, visual, haptic and visual-haptic assistance functions are presented. These support the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic assistance are demonstrated in a user study. The system performance and usability of the overall robotic system are assessed in an additional user study. Analogous to a clinical scenario, the subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergeführten Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die Bildgebung, die Planung und Ausführung der Laserablation sowie intraoperative Bewegungen des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen für die endoskopische Applikation fokussierter Laserstrahlung verfügbar. Ebenfalls sind keine Systeme bekannt, die Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausführung einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fünf Freiheitsgraden. Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen einen positiven Effekt der Automationskonzepte für die kontaktfreie Laserchirurgie

    Lab-on-a-Chip Fabrication and Application

    Get PDF
    The necessity of on-site, fast, sensitive, and cheap complex laboratory analysis, associated with the advances in the microfabrication technologies and the microfluidics, made it possible for the creation of the innovative device lab-on-a-chip (LOC), by which we would be able to scale a single or multiple laboratory processes down to a chip format. The present book is dedicated to the LOC devices from two points of view: LOC fabrication and LOC application
    corecore