1,525 research outputs found
Comprehensive design and propagation study of a compact dual band antenna for healthcare applications
In this paper, a dual band planar inverted F antenna (PIFA) has been investigated for cooperative on- and off-body communications. Free space and on-body performance parameters like return loss, bandwidth, radiation pattern and efficiency of this antenna are shown and investigated. The on- and off-body radio propagation channel performance at 2.45 GHz and 1.9 GHz have been investigated, respectively. Experimental investigations are performed both in the anechoic chamber and in an indoor environment. The path loss exponent has been extracted for both on- and off-body radio propagation scenarios. For on-body propagation, the path loss exponent is 2.48 and 2.22 in the anechoic chamber and indoor environment, respectively. The path loss exponent is 1.27 for off-body radio propagation situation. For on-body case, the path loss has been characterized for ten different locations on the body at 2.45 GHz, whereas for off-body case radio channel studies are performed for five different locations at 1.9 GHz. The proposed antenna shows a good on- and off-body radio channel performance
A Comprehensive Review of Wearable Antenna Design for On-Body and Off-Body Communication
Today age of advancement one of the fastest growing fields of the technology is wearable electronics and device. In the recent advancement the wearable devices for on and off body communication is going expeditiously. For the wearable wireless communication, wearable antennas are mostly used due to its compact size, self powered, light weight, low profile, portable wireless communication and sensing. This paper throws light on wearable antennas for on body and off body communication including their applications, advantages and disadvantages. A comparative study is conducted on designing of different on body and off body wearable antennas and parameters of designed antenna such as their size, shape, gain, SAR have been compared and analyzed. In this paper also discussed the impact of the wearable antenna on human body and impact of human body on antenn
Wireless body sensor networks for health-monitoring applications
This is an author-created, un-copyedited version of an article accepted for publication in
Physiological Measurement. The publisher is
not responsible for any errors or omissions in this version of the manuscript or any version
derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01
A Comprehensive Survey on RF Energy Harvesting: Applications and Performance Determinants
\ua9 2022 by the authors. Licensee MDPI, Basel, Switzerland.There has been an explosion in research focused on Internet of Things (IoT) devices in recent years, with a broad range of use cases in different domains ranging from industrial automation to business analytics. Being battery-powered, these small devices are expected to last for extended periods (i.e., in some instances up to tens of years) to ensure network longevity and data streams with the required temporal and spatial granularity. It becomes even more critical when IoT devices are installed within a harsh environment where battery replacement/charging is both costly and labour intensive. Recent developments in the energy harvesting paradigm have significantly contributed towards mitigating this critical energy issue by incorporating the renewable energy potentially available within any environment in which a sensor network is deployed. Radio Frequency (RF) energy harvesting is one of the promising approaches being investigated in the research community to address this challenge, conducted by harvesting energy from the incident radio waves from both ambient and dedicated radio sources. A limited number of studies are available covering the state of the art related to specific research topics in this space, but there is a gap in the consolidation of domain knowledge associated with the factors influencing the performance of RF power harvesting systems. Moreover, a number of topics and research challenges affecting the performance of RF harvesting systems are still unreported, which deserve special attention. To this end, this article starts by providing an overview of the different application domains of RF power harvesting outlining their performance requirements and summarizing the RF power harvesting techniques with their associated power densities. It then comprehensively surveys the available literature on the horizons that affect the performance of RF energy harvesting, taking into account the evaluation metrics, power propagation models, rectenna architectures, and MAC protocols for RF energy harvesting. Finally, it summarizes the available literature associated with RF powered networks and highlights the limitations, challenges, and future research directions by synthesizing the research efforts in the field of RF energy harvesting to progress research in this area
Sub-GHz Wrist-Worn Antennas for Wireless Sensing Applications: A Review
With recent advances in wearable wrist-worn wireless sensing applications, the demand for smartwatches and wristbands is rapidly increasing due to their widespread adoption in applications such as smart health monitoring, security, and fitness tracking. Currently, these devices primarily operate in the 2.45 GHz band, leveraging the availability of Bluetooth and Wi-Fi wireless technologies. However, the use of Sub-GHz frequencies (e.g., 433 MHz, 868 MHz, 915 MHz, 923 MHz) for wearable systems has also gained interest due to the emergence of wireless technologies like long-range wide area network (LoRaWAN), narrowband-IoT (NB-IoT) and Sigfox, which offer the potential for long-range wireless communications and sensing applications. In recent times, there has been a notable surge in the commercial production of a variety of Sub-GHz wrist-worn wireless sensing devices for health monitoring and tracking applications. Nevertheless, communications at Sub-GHz frequencies present significant challenges in antenna design, primarily due to the practical size constraints of wrist-worn devices and the necessity for using electrically small antennas. This paper meticulously reviews wrist-worn Sub-GHz antennas reported in the literature, analyzing key antenna parameters such as antenna topology, size, impedance bandwidth, peak realized gain, radiation efficiency, and specific absorption rate (SAR). Additionally, it underlines antenna design challenges, limitations, current trends, and presents potential future perspectives. To the best of the author’s knowledge, there is currently no existing literature comprehensively reviewing Sub-GHz wrist-worn antennas. Therefore, this paper represents the inaugural effort to provide a comprehensive review in this specific domain
A review of recent innovations in remote health monitoring
The development of remote health monitoring systems has focused on enhancing healthcare services’ efficiency and quality, particularly in chronic disease management and elderly care. These systems employ a range of sensors and wearable devices to track patients’ health status and offer real-time feedback to healthcare providers. This facilitates prompt interventions and reduces hospitalization rates. The aim of this study is to explore the latest developments in the realm of remote health monitoring systems. In this paper, we explore a wide range of domains, spanning antenna designs, small implantable antennas, on-body wearable solutions, and adaptable detection and imaging systems. Our research also delves into the methodological approaches used in monitoring systems, including the analysis of channel characteristics, advancements in wireless capsule endoscopy, and insightful investigations into sensing and imaging techniques. These advancements hold the potential to improve the accuracy and efficiency of monitoring, ultimately contributing to enhanced health outcomes for patients.Publisher's VersionQ2WOS:001130630400001PMID:3813832
Antenna and radio channel characterisation for low‐power personal and body area networks
PhDThe continuous miniaturisation of sensors, as well as the progression in wearable electronics,
embedded software, digital signal processing and biomedical technologies, have led to new usercentric
networks, where devices can be carried in the user’s pockets, attached to the user’s body.
Body-centric wireless communications (BCWCs) is a central point in the development of fourth
generation mobile communications. Body-centric wireless networks take their place within the
personal area networks, body area networks and sensor networks which are all emerging
technologies that have a wide range of applications (such as, healthcare, entertainment,
surveillance, emergency, sports and military). The major difference between BCWC and
conventional wireless systems is the radio channels over which the communication takes place.
The human body is a hostile environment from a radio propagation perspective and it is therefore
important to understand and characterise the effects of the human body on the antenna elements,
the radio channel parameters and, hence, system performance. This thesis focuses on the study of
body-worn antennas and on-body radio propagation channels.
The performance parameters of five different narrowband (2.45 GHz) and four UWB (3.1-
10.6 GHz) body-worn antennas in the presence of human body are investigated and compared.
This was performed through a combination of numerical simulations and measurement
campaigns. Parametric studies and statistical analysis, addressing the human body effects on the
performance parameters of different types of narrowband and UWB antennas have been
presented. The aim of this study is to understand the human body effects on the antenna
parameters and specify the suitable antenna in BCWCs at both 2.45 GHz and UWB frequencies.
Extensive experimental investigations are carried out to study the effects of various antenna
types on the on-body radio propagation channels as well. Results and analysis emphasize the best
body-worn antenna for reliable and power-efficient on-body communications. Based on the
results and analysis, a novel dual-band and dual-mode antenna is proposed for power-efficient
and reliable on-body and off-body communications. The on-body performance of the DBDM
antenna at 2.45 GHz is compared with other five narrowband antennas. Based on the results and
analysis of six narrowband and four UWB antennas, antenna specifications and design guidelines
are provided that will help in selecting the best body-worn antenna for both narrowband and
UWB systems to be applied in body-centric wireless networks (BCWNs). A comparison between
IV
the narrowband and UWB antenna parameters are also provided. At the end of the thesis, the
subject-specificity of the on-body radio propagation channel at 2.45 GHz and 3-10 GHz was
experimentally investigated by considering eight real human test subjects of different shapes,
heights and sizes. The subject-specificity of the on-body radio propagation channels was
compared between the narrowband and UWB systems as well
A Dual Band Crossed Slot Antenna for L5 and S Band
In the present work a dual band circularly polarized antenna for satellite applications resonating at S(2.492GHz) and L5(1.16GHz)band of frequency has been presented using probe feeding technique. The new aspect of the suggested work is the use of triangular-shaped corner trimming along the patch's diagonal and 45-degree slanted rectangular slots to accomplish circular polarization. The radiating structure resulted in an input reflection coefficient of -20.249dB and -30.524dB in the L5 and S band respectively along with a bandwidth of 0.0605GHz and 0.0916GHz. The axial ratio reported was close to 3 dB in the L5 band of the antenna
- …