    Operation of a 1-Liter-Volume Gaseous Argon Scintillation Counter

    Full text link
    We have built a gas-phase argon ionization detector to measure small nuclear recoil energies (< 10 keVee). In this paper, we describe the detector response to X-ray and gamma calibration sources, including analysis of pulse shapes, software triggers, optimization of gas content, and energy- and position-dependence of the signal. We compare our experimental results against simulation using a 5.9-keV X-ray source, as well as higher-energy gamma sources up to 1332 keV. We conclude with a description of the detector, DAQ, and software settings optimized for a measurement of the low-energy nuclear quenching factor in gaseous argon. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory in part under Contract W-7405-Eng-48 and in part under Contract DE-AC52-07NA27344. Funded by Lab-wide LDRD. LLNL-JRNL-415990-DRAFT.Comment: 29 pages, single-column, double-spaced, 21 figure

    On the Properties of Plastic Ablators in Laser-Driven Material Dynamics Experiments

    Full text link
    Radiation hydrodynamics simulations were used to study the effect of plastic ablators in laser-driven shock experiments. The sensitivity to composition and equation of state was found to be 5-10% in ablation pressure. As was found for metals, a laser pulse of constant irradiance gave a pressure history which decreased by several percent per nanosecond. The pressure history could be made more constant by adjusting the irradiance history. The impedance mismatch with the sample gave an increase o(100%) in the pressure transmitted into the sample, for a reduction of several tens of percent in the duration of the peak load applied to the sample, and structured the release history by adding a release step to a pressure close to the ablation pressure. Algebraic relations were found between the laser pulse duration, the ablator thickness, and the duration of the peak pressure applied to the sample, involving quantities calculated from the equations of state of the ablator and sample using shock dynamics.Comment: Typos fixe

    Development, Validation, and Clinical Application of a Numerical Model for Pulse Wave Velocity Propagation in a Cardiovascular System with Application to Noninvasive Blood Pressure Measurements

    Get PDF
    High blood pressure blood pressure is an important risk factor for cardiovascular disease and affects almost one-third of the U.S. adult population. Historical cuff-less non-invasive techniques used to monitor blood pressure are not accurate and highlight the need for first principal models. The first model is a one-dimensional model for pulse wave velocity (PWV) propagation in compliant arteries that accounts for nonlinear fluids in a linear elastic thin walled vessel. The results indicate an inverse quadratic relationship (R^2=.99) between ejection time and PWV, with ejection time dominating the PWV shifts (12%). The second model predicts the general relationship between PWV and blood pressure with a rigorous account of nonlinearities in the fluid dynamics, blood vessel elasticity, and finite dynamic deformation of a membrane type thin anisotropic wall. The nonlinear model achieves the best match with the experimental data. To retrieve individual vascular information of a patient, the inverse problem of hemodynamics is presented, calculating local orthotropic hyperelastic properties of the arterial wall. The final model examines the impact of the thick arterial wall with different material properties in the radial direction. For a hypertensive subject the thick wall model provides improved accuracy up to 8.4% in PWV prediction over its thin wall counterpart. This translates to nearly 20% improvement in blood pressure prediction based on a PWV measure. The models highlight flow velocity is additive to the classic pressure wave, suggesting flow velocity correction may be important for cuff-less, non-invasive blood pressure measures. Systolic flow correction of the measured PWV improves the R2 correlation to systolic blood pressure from 0.81 to 0.92 for the mongrel dog study, and 0.34 to 0.88 for the human subjects study. The algorithms and insight resulting from this work can enable the development of an integrated microsystem for cuff-less, non-invasive blood pressure monitoring

    Visco-Node-Pore Sensing: A Microfluidic Rheology Platform to Characterize Viscoelastic Properties of Epithelial Cells.

    Get PDF
    Viscoelastic properties of cells provide valuable information regarding biological or clinically relevant cellular characteristics. Here, we introduce a new, electronic-based, microfluidic platform-visco-node-pore sensing (visco-NPS)-which quantifies cellular viscoelastic properties under periodic deformation. We measure the storage (G) and loss (G″) moduli (i.e., elasticity and viscosity, respectively) of cells. By applying a wide range of deformation frequencies, our platform quantifies the frequency dependence of viscoelastic properties. G and G″ measurements show that the viscoelastic properties of malignant breast epithelial cells (MCF-7) are distinctly different from those of non-malignant breast epithelial cells (MCF-10A). With its sensitivity, visco-NPS can dissect the individual contributions of different cytoskeletal components to whole-cell mechanical properties. Moreover, visco-NPS can quantify the mechanical transitions of cells as they traverse the cell cycle or are initiated into an epithelial-mesenchymal transition. Visco-NPS identifies viscoelastic characteristics of cell populations, providing a biophysical understanding of cellular behavior and a potential for clinical applications

    PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms using Fully Convolutional Neural Networks

    Full text link
    Cardiovascular diseases are one of the most severe causes of mortality, taking a heavy toll of lives annually throughout the world. The continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, bringing about several layers of complexities. This motivates us to develop a method to predict the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using photoplethysmogram (PPG) signals. In addition we explore the advantage of deep learning as it would free us from sticking to ideally shaped PPG signals only, by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present, PPG2ABP, a deep learning based method, that manages to predict the continuous ABP waveform from the input PPG signal, with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of DBP, MAP and SBP from the predicted ABP waveform outperforms the existing works under several metrics, despite that PPG2ABP is not explicitly trained to do so

    Estimación robusta de la diferencia del tiempo de tránsito del pulso sanguíneo a partir de señales fotopletismográficas

    Get PDF
    En el presente trabajo se va a estudiar la posibilidad de detectar estrés mental utilizando técnicas no invasivas basadas en la señal fotopletismográfica de pulso (PPG). Para ello se pretende detectar cambios en la velocidad de pulso arterial (PWV), utilizando señales de PPG tomadas en dos puntos distintos del árbol arterial con las que poder medir el tiempo de llegada de pulso arterial a la periferia (PAT) y la diferencia de ese tiempo de llegada entre dos puntos de la periferia distintos (PTTD). Tanto el PAT como el PTTD han sido propuestas en la bibliografía como medidas influenciados por el Tiempo de Tránsito de Pulso (PTT), este último capaz de medir cambios en la dinámica cardiovascular. Sin embargo, el PTTD, al contrario que el PAT, no necesita del electrocardiograma (ECG) para ser obtenido y no está influenciado por el periodo de pre-eyección (PEP) -un intervalo de tiempo en la sístole ventricular que cambia pulso a pulso- el cual genera que el PAT pierda la relación con el PTT, dos factores importantes que aventajan al PTTD frente al PAT. Primero, se estudia de fiabilidad de los puntos fiduciales para la detección de los pulsos de la señal PPG y con ésto comprobar cuál es el método con la mayor precisión. Se demuestra mediante diversos análisis que el mejor punto para detectar los pulsos corresponde al valor de la PPG en el instante de máxima pendiente (valor máximo en la primera derivada). Resulta necesario implementar un detector de artefactos ya que el método de adquisición de la PPG es muy sensible a ellos pudiendo llegar a haber segmentos en los que la señal registrada es absolutamente inutilizable. Posteriormente, se analizan 14 voluntarios sanos sometidos a un protocolo de estrés y se realiza un test estadístico para comprobar la validez del método propuesto. Los resultados muestran que la desviación estándar de la PTTD tiene la capacidad estadística suficiente como para discernir entre estados de estrés y de relajación, para cada uno de los sujetos por separado. Además, se puede ver una tendencia descendente generalizada del descenso de la PTTD en situación de estrés con respecto a relajación. %Sin embargo, resultará necesario repetir el análisis con una muestra de señales mayor ya que se dispone de pocos sujetos en la base de datos utilizada, ya que la calidad de la señal de PPG que se registró en la frente es muy mala y hay muy pocos sujetos con los que se puede computar la PTTD. A modo de conclusión, se ha visto que la PTTD contiene información fisiológica que puede ser interesante para la detección de estrés. A su vez, también es una técnica potencialmente interesante para otros tipos de aplicaciones clínicas tales como la estimación no invasiva de la presión arterial o la evaluación de la rigidez arterial, pero se necesita estudiar la adecuación de ésta en cada escenario en particular. Además, como la PTTD se puede medir a partir de únicamente dos señales PPG, la técnica es idónea para dispositivos wearable y smartphones
    • …