3,701 research outputs found
On-Off Intermittency in Time Series of Spontaneous Paroxysmal Activity in Rats with Genetic Absence Epilepsy
Dynamic behavior of complex neuronal ensembles is a topic comprising a
streamline of current researches worldwide. In this article we study the
behavior manifested by epileptic brain, in the case of spontaneous
non-convulsive paroxysmal activity. For this purpose we analyzed archived
long-term recording of paroxysmal activity in animals genetically susceptible
to absence epilepsy, namely WAG/Rij rats. We first report that the brain
activity alternated between normal states and epilepsy paroxysms is the on-off
intermittency phenomenon which has been observed and studied earlier in the
different nonlinear systems.Comment: 11 pages, 6 figure
An Automated System for Epilepsy Detection using EEG Brain Signals based on Deep Learning Approach
Epilepsy is a neurological disorder and for its detection, encephalography
(EEG) is a commonly used clinical approach. Manual inspection of EEG brain
signals is a time-consuming and laborious process, which puts heavy burden on
neurologists and affects their performance. Several automatic techniques have
been proposed using traditional approaches to assist neurologists in detecting
binary epilepsy scenarios e.g. seizure vs. non-seizure or normal vs. ictal.
These methods do not perform well when classifying ternary case e.g. ictal vs.
normal vs. inter-ictal; the maximum accuracy for this case by the
state-of-the-art-methods is 97+-1%. To overcome this problem, we propose a
system based on deep learning, which is an ensemble of pyramidal
one-dimensional convolutional neural network (P-1D-CNN) models. In a CNN model,
the bottleneck is the large number of learnable parameters. P-1D-CNN works on
the concept of refinement approach and it results in 60% fewer parameters
compared to traditional CNN models. Further to overcome the limitations of
small amount of data, we proposed augmentation schemes for learning P-1D-CNN
model. In almost all the cases concerning epilepsy detection, the proposed
system gives an accuracy of 99.1+-0.9% on the University of Bonn dataset.Comment: 18 page
The status of textile-based dry EEG electrodes
Electroencephalogram (EEG) is the biopotential recording of electrical signals generated by brain activity. It is useful for monitoring sleep quality and alertness, clinical applications, diagnosis, and treatment of patients with epilepsy, disease of Parkinson and other neurological disorders, as well as continuous monitoring of tiredness/ alertness in the field. We provide a review of textile-based EEG. Most of the developed textile-based EEGs remain on shelves only as published research results due to a limitation of flexibility, stickability, and washability, although the respective authors of the works reported that signals were obtained comparable to standard EEG. In addition, nearly all published works were not quantitatively compared and contrasted with conventional wet electrodes to prove feasibility for the actual application. This scenario would probably continue to give a publication credit, but does not add to the growth of the specific field, unless otherwise new integration approaches and new conductive polymer composites are evolved to make the application of textile-based EEG happen for bio-potential monitoring
Automatic Detection of Seizures with Applications
There are an estimated two million people with epilepsy in the United States. Many of these people do not respond to anti-epileptic drug therapy. Two devices can be developed to assist in the treatment of epilepsy. The first is a microcomputer-based system designed to process massive amounts of electroencephalogram (EEG) data collected during long-term monitoring of patients for the purpose of diagnosing seizures, assessing the effectiveness of medical therapy, or selecting patients for epilepsy surgery. Such a device would select and display important EEG events. Currently many such events are missed. A second device could be implanted and would detect seizures and initiate therapy. Both of these devices require a reliable seizure detection algorithm. A new algorithm is described. It is believed to represent an improvement over existing seizure detection algorithms because better signal features were selected and better standardization methods were used
Classification of Epileptic EEG Signals by Wavelet based CFC
Electroencephalogram, an influential equipment for analyzing humans
activities and recognition of seizure attacks can play a crucial role in
designing accurate systems which can distinguish ictal seizures from regular
brain alertness, since it is the first step towards accomplishing a high
accuracy computer aided diagnosis system (CAD). In this article a novel
approach for classification of ictal signals with wavelet based cross frequency
coupling (CFC) is suggested. After extracting features by wavelet based CFC,
optimal features have been selected by t-test and quadratic discriminant
analysis (QDA) have completed the Classification.Comment: Electroencephalogram; Wavelet Decomposition; Cross Frequency
Coupling;Quadratic Discriminant Analysis; T-test Feature Selectio
Epilepsy Detection Using Artificial Neural Networks
Epilepsy is a neurological disorder, where there is a cluster of brain cells that behave in a hyperexcitable manner, the individual can promote injuries, trauma or, in more severe cases, sudden death. Electroencephalogram (EEG) is the most used way to detect epileptic seizures. Therefore, more simplified methods of analysis of the EEG can help in the diagnosis and treatment of these individuals more quickly. In this study, we extracted pertinent EEG characteristics to assess the epileptic seizure period. We use Perceptron Multilayer artificial neural networks to classify the period of the crisis, obtaining a more efficient diagnosis. The multilayer neural network obtained an accuracy of 98%. Thus, the strategy of extracting characteristics and the architecture of the assigned network were sufficient for a rapid and accurate diagnosis of epilepsy
- …