    Assessment of radio frequency exposures in schools, homes, and public places in Belgium

    Get PDF
    Characterization of exposure from emerging radio frequency (RF) technologies in areas where children are present is important. Exposure to RF electromagnetic fields (EMF) was assessed in three "sensitive" microenvironments; namely, schools, homes, and public places located in urban environments and compared to exposure in offices. In situ assessment was conducted by performing spatial broadband and accurate narrowband measurements, providing 6-min averaged electric-field strengths. A distinction between internal (transmitters that are located indoors) and external (outdoor sources from broadcasting and telecommunication) sources was made. Ninety-four percent of the broadband measurements were below 1 V m(-1). The average and maximal total electric-field values in schools, homes, and public places were 0.2 and 3.2 V m(-1) (WiFi), 0.1 and 1.1 V m(-1) (telecommunication), and 0.6 and 2.4 V m(-1) (telecommunication), respectively, while for offices, average and maximal exposure were 0.9 and 3.3 V m(-1) (telecommunication), satisfying the ICNIRP reference levels. In the schools considered, the highest maximal and average field values were due to internal signals (WiFi). In the homes, public places, and offices considered, the highestmaximal and average field values originated from telecommunication signals. Lowest exposures were obtained in homes. Internal sources contributed on average more indoors (31.2%) than outdoors (2.3%), while the average contributions of external sources (broadcast and telecommunication sources) were higher outdoors (97.7%) than at indoor positions (68.8%). FM, GSM, and UMTS dominate the total downlink exposure in the outdoor measurements. In indoor measurements, FM, GSM, and WiFi dominate the total exposure. The average contribution of the emerging technology LTE was only 0.6%

    In-situ measurement methodology for the assessment of 5G NR massive MIMO base station exposure at sub-6 GHz frequencies

    Get PDF
    As the roll-out of the fifth generation (5G) of mobile telecommunications is well underway, standardized methods to assess the human exposure to radiofrequency electromagnetic fields from 5G base station radios are needed in addition to existing numerical models and preliminary measurement studies. Challenges following the introduction of 5G New Radio (NR) include the utilization of new spectrum bands and the widespread use of technological advances such as Massive MIMO (Multiple-Input Multiple-Output) and beamforming. We propose a comprehensive and ready-to-use exposure assessment methodology for use with common spectrum analyzer equipment to measure or calculate in-situ the time-averaged instantaneous exposure and the theoretical maximum exposure from 5G NR base stations. Besides providing the correct method and equipment settings to capture the instantaneous exposure, the procedure also comprises a number of steps that involve the identification of the Synchronization Signal Block, which is the only 5G NR component that is transmitted periodically and at constant power, the assessment of the power density carried by its resources, and the subsequent extrapolation to the theoretical maximum exposure level. The procedure was validated on site for a 5G NR base station operating at 3.5 GHz, but it should be generally applicable to any 5G NR signal, i.e., as is for any sub-6 GHz signal and after adjustment of the proposed measurement settings for signals in the millimeter-wave range

    A personal, distributed exposimeter: procedure for design, calibration, validation, and application

    Get PDF
    This paper describes, for the first time, the procedure for the full design, calibration, uncertainty analysis, and practical application of a personal, distributed exposimeter (PDE) for the detection of personal exposure in the Global System for Mobile Communications (GSM) downlink (DL) band around 900 MHz (GSM 900 DL). The PDE is a sensor that consists of several body-worn antennas. The on-body location of these antennas is investigated using numerical simulations and calibration measurements in an anechoic chamber. The calibration measurements and the simulations result in a design (or on-body setup) of the PDE. This is used for validation measurements and indoor radio frequency (RF) exposure measurements in Ghent, Belgium. The main achievements of this paper are: first, the demonstration, using both measurements and simulations, that a PDE consisting of multiple on-body textile antennas will have a lower measurement uncertainty for personal RF exposure than existing on-body sensors; second, a validation of the PDE, which proves that the device correctly estimates the incident power densities; and third, a demonstration of the usability of the PDE for real exposure assessment measurements. To this aim, the validated PDE is used for indoor measurements in a residential building in Ghent, Belgium, which yield an average incident power density of 0.018 mW/m(2)

    Procedure for assessment of general public exposure from Wlan in offices and in wireless sensor network testbed

    Get PDF
    A fast and accurate measurement procedure to determine experimentally wireless local area network (WLAN) radiofrequency (RF) exposure and to test compliance with international guidelines for the general public is proposed. This is the first paper where all optimal settings for the measurement equipment (sweep time, resolution bandwidth, etc.) are investigated, selected, and validated. The exposure to WLAN access points is determined for 222 locations with 7 WLAN networks present in office environments. The WLAN exposure is also characterized for the first time in a wireless sensor lab environment (WiLab) at IBBT-Ghent University in Belgium. Average background exposure to WLAN (WiLab off) is 0.12 V m(-1), with a 95(th) percentile of 0.90 V m(-1). With the WiLab in operation, average exposure increases to 1.9 V m(-1), with a 95(th) percentile of 4.7 V m(-1). All values are well below the International Commission on Non Ionizing Radiation Protection guidelines of 61 V m(-1) in the 2.4 GHz band (at least 9.1 times for distances of more than 1 m from the access points) but a significant increase of exposure is possible in WiLabs due to high duty cycles. By applying the proposed measurement method a relevant reduction in measurement time is obtained. Health Phys. 98(4):628-638; 201

    Assessment of long-term spatio-temporal radiofrequency electromagnetic field exposure

    Get PDF
    As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42 dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations

    Numerically simulated exposure of children and adults to pulsed gradient fields in MRI

    Get PDF
    PurposeTo determine exposure to gradient switching fields of adults and children in a magnetic resonance imaging (MRI) scanner by evaluating internal electric fields within realistic models of adult male, adult female, and child inside transverse and longitudinal gradient coils, and to compare these results with compliance guidelines. Materials and MethodsPatients inside x-, y-, and z-gradient coils were simulated using anatomically realistic models of adult male, adult female, and child. The induced electric fields were computed for 1 kHz sinusoidal current with a magnitude of 1 A in the gradient coils. Rheobase electric fields were then calculated and compared to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2004 and International Electrotechnical Commission (IEC) 2010 guidelines. The effect of the human body, coil type, and skin conductivity on the induced electric field was also investigated. ResultsThe internal electric fields are within the first level controlled operating mode of the guidelines and range from 2.7V m(-1) to 4.5V m(-1), except for the adult male inside the y-gradient coil (induced field reaches 5.4V m(-1)).The induced electric field is sensitive to the coil type (electric field in the skin of adult male: 4V m(-1), 4.6V m(-1), and 3.8V m(-1) for x-, y-, and z-gradient coils, respectively), the human body model (electric field in the skin inside y-gradient coil: 4.6V m(-1), 4.2V m(-1), and 3V m(-1) for adult male, adult female, and child, respectively), and the skin conductivity (electric field 2.35-4.29% higher for 0.1S m(-1) skin conductivity compared to 0.2S m(-1)). ConclusionThe y-gradient coil induced the largest fields in the patients. The highest levels of internal electric fields occurred for the adult male model. J. Magn. Reson. Imaging 2016;44:1360-1367

    On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity

    Get PDF
    This paper describes the design, calibration, and measurements with a personal, distributed exposimeter (PDE) for the on-body detection of radio frequency (RF) electromagnetic fields due to Wireless Fidelity (WiFi) networks. Numerical simulations show that using a combination of two RF nodes placed on the front and back of the body reduces the 50% prediction interval (PI50) on the incident free-space electric-field strength E-RMS(free). Median reductions of 10 dB and 9.1 dB are obtained compared to the PI50 of a single antenna placed on the body using a weighted arithmetic and geometric average, respectively. Therefore, a simple PDE topology based on two nodes, which are deployed on opposite sides of the human torso, is applied for calibration and measurements. The PDE is constructed using flexible, dual-polarized textile antennas and wearable electronics, which communicate wirelessly with a Universal Serial Bus (USB) connected receiver and can be unobtrusively integrated into a garment. The calibration of the PDE in an anechoic chamber proves that the PI50 of the measured E-RMS(free) is reduced to 3.2 dB. To demonstrate the real-life usability of the wireless device, a subject was equipped with the PDE during a walk in the city of Ghent, Belgium. Using a sample frequency of 2 Hz, an average incident power density of 59 nW m(-2) was registered in the WiFi frequency band during this walk

    In silico evaluation of the thermal stress induced by MRI switched gradient fields in patients with metallic hip implant

    Get PDF
    This work focuses on the in silico evaluation of the energy deposed by MRI switched gradient fields in bulk metallic implants and the consequent temperature increase in the surrounding tissues. An original computational strategy, based on the subdivision of the gradient coil switching sequences into sub-signals and on the time-harmonic electromagnetic field solution, allows to realistically simulate the evolution of the phenomena produced by the gradient coils fed according to any MRI sequence. Then, Pennes' bioheat equation is solved through a Douglas-Gunn time split scheme to compute the time-dependent temperature increase. The procedure is validated by comparison with laboratory results, using a component of a realistic hip implant embedded within a phantom, obtaining an agreement on the temperature increase better than 5%, lower than the overall measurement uncertainty. The heating generated inside the body of a patient with a unilateral hip implant when undergoing an Echo-Planar Imaging (EPI) MRI sequence is evaluated and the role of the parameters affecting the thermal results (body position, coil performing the frequency encoding, effects of thermoregulation) is discussed. The results show that the gradient coils can generate local increases of temperature up to some kelvin when acting without radiofrequency excitation. Hence, their contribution in general should not be disregarded when evaluating patients' safety

    Emissions from smart meters and other residential radiofrequency sources

    Get PDF
    The advent of the Internet of things comes with a huge increase in wirelessly communicating devices in our environment. For example, smart energy-consumption meters are being widely deployed in residences from which they communicate their state using radiofrequency networks. Accurate characterization of the radiofrequency emissions from emerging residential wireless solutions is important to inform the public about the potential impact on their exposure to radiofrequency electromagnetic fields. A new measurement procedure to determine the exposure from residential radiofrequency devices is proposed by assessing the peak emitted fields at various distances and the proportion of time they transmit (duty cycle). Radiofrequency emissions from 55 residential devices were measured in 10 residences (Belgium and France) and compared to environmental levels, emissions from 41 mobile phones, and international standards. Overall, residential levels of radiofrequency electromagnetic field exposure are low. In addition to the continuous environmental exposure, wireless access points (due to frequent use) and especially mobile phones and other personal communication devices (due to their use close to the body) continue to represent the bulk of the radiofrequency electromagnetic field exposure in the smart home. However, some residential devices can significantly increase the exposure if their duty cycles are high enough (>10%), especially when held or used close to the body. Individual smart meters, on the other hand, will contribute only little in general, despite emissions of up to 20 V m(-1) at 50 cm, due to their low duty cycles (maximum 1%) and locations
    • …