2,678 research outputs found

    Advanced sensors technology survey

    Get PDF
    This project assesses the state-of-the-art in advanced or 'smart' sensors technology for NASA Life Sciences research applications with an emphasis on those sensors with potential applications on the space station freedom (SSF). The objectives are: (1) to conduct literature reviews on relevant advanced sensor technology; (2) to interview various scientists and engineers in industry, academia, and government who are knowledgeable on this topic; (3) to provide viewpoints and opinions regarding the potential applications of this technology on the SSF; and (4) to provide summary charts of relevant technologies and centers where these technologies are being developed

    Variable Spurious Noise Mitigation Techniques in Hysteretic Buck Converters

    Get PDF
    This work proposes a current-mode hysteretic buck converter with a spur-free constant-cycle frequency-hopping controller that fully eliminates spurs from the switching noise spectrum irrespective of variations in the switching frequency and operating conditions. As a result, the need for frequency regulation loops to ensure non-varying switching frequency (i.e. fixed spurs location) in hysteretic controllers is eliminated. Moreover, compared to frequency regulation loops, the proposed converter offers the advantage of eliminating mixing and interference altogether due to its spur-free operation, and thus, it can be used to power, or to be integrated within noise-sensitive systems while benefiting from the superior dynamic performance of its hysteretic operation. The proposed converter uses dual-sided hysteretic band modulation to eliminate the inductor current imbalance that results from frequency hopping along with the output voltage transients and low-frequency noise floor peaking associated with it. Moreover, a feedforward adaptive hysteretic band controller is proposed to reduce variations in the switching frequency with the input voltage, and an all-digital soft-startup circuit is proposed to control the in-rush current without requiring any off-chip components. The converter is implemented in a 0.35-ĂƒĂ‚Â”m standard CMOS technology and it achieves 92% peak efficiency

    Power management systems based on switched-capacitor DC-DC converter for low-power wearable applications

    Get PDF
    The highly efficient ultra-low-power management unit is essential in powering low-power wearable electronics. Such devices are powered by a single input source, either by a battery or with the help of a renewable energy source. Thus, there is a demand for an energy conversion unit, in this case, a DC-DC converter, which can perform either step-up or step-down conversions to provide the required voltage at the load. Energy scavenging with a boost converter is an intriguing choice since it removes the necessity of bulky batteries and considerably extends the battery life. Wearable devices are typically powered by a monolithic battery. The commonly available battery such as Alkaline or Lithium-ion, degrade over time due to their life spans as it is limited by the number of charge cycles- which depend highly on the environmental and loading condition. Thus, once it reaches the maximum number of life cycles, the battery needs to be replaced. The operation of the wearable devices is limited by usable duration, which depends on the energy density of the battery. Once the stored energy is depleted, the operation of wearable devices is also affected, and hence it needs to be recharged. The energy harvesters- which gather the available energy from the surroundings, however, have no limitation on operating life. The application can become battery-less given that harvestable energy is sufficiently powering the low-power devices. Although the energy harvester may not completely replace the battery source, it ensures the maximum duration of use and assists to become autonomous and self-sustain devices. The photovoltaic (PV) cell is a promising candidate as a hypothetical input supply source among the energy harvesters due to its smaller area and high power density over other harvesters. Solar energy use PV harvester can convert ambient light energy into electrical energy and keep it in the storage device. The harvested output of PV cannot directly connect to wearable loads for two main reasons. Depending on the incoming light, the harvested current result in varying open-circuit voltage. It requires the power management circuit to deal with unregulated input variation. Second, depending on the PV cell's material type and an effective area, the I-V characteristic's performance varies, resulting in a variation of the output power. There are several works of maximum power point tracking (MPPT) methods that allow the solar energy harvester to achieve optimal harvested power. Therefore, the harvested power depends on the size and usually small area cell is sufficient for micro-watt loads low-powered applications. The available harvested voltage, however, is generally very low-voltage range between 0.4-0.6 V. The voltage ratings of electronics in standard wearable applications operate in 1.8-3 V voltages as described in introduction’s application example section. It is higher than the supply source can offer. The overcome the mismatch voltage between source and supply circuit, a DC-DC boost converter is necessary. The switch-mode converters are favoured over the linear converters due to their highly efficient and small area overhead. The inductive converter in the switch-mode converter is common due to its high-efficiency performance. However, the integration of the inductor in the miniaturised integrated on-chip design tends to be bulky. Therefore, the switched-capacitor approach DC-DC converters will be explored in this research. In the switched-capacitor converter universe, there is plenty of work for single-output designs for various topologies. Most converters are reconfigurable to the different DC voltage levels apart from Dickson and cross-coupled charge pump topologies due to their boosting power stage architecture through a number of stages. However, existing multi-output converters are limited to the fixed gain ratio. This work explores the reconfigurable dual-output converter with adjustable gain to compromise the research gap. The thesis's primary focus is to present the inductor-less, switched-capacitor-based DC-DC converter power management system (PMS) supplied by a varying input of PV energy harvester input source. The PMS should deliver highly efficient regulated voltage conversion ratio (VCR) outputs to low-power wearable electronic devices that constitute multi-function building blocks

    Self-Powered Portable Electronic Reader for Point-of-Care Amperometric Measurements

    Get PDF
    In this work, we present a self-powered electronic reader (e-reader) for point-of-care diagnostics based on the use of a fuel cell (FC) which works as a power source and as a sensor. The self-powered e-reader extracts the energy from the FC to supply the electronic components concomitantly, while performing the detection of the fuel concentration. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low power device without needing an external power source. Besides, the custom electronic instrumentation platform can process and display fuel concentration without requiring any type of laboratory equipment. In this study, we present the electronics system in detail and describe all modules that make up the system. Furthermore, we validate the device's operation with different emulated FCs and sensors presented in the literature. The e-reader can be adjusted to numerous current ranges up to 3 mA, with a 13 nA resolution and an uncertainty of 1.8%. Besides, it only consumes 900 ”W in the low power mode of operation, and it can operate with a minimum voltage of 330 mV. This concept can be extended to a wide range of fields, from biomedical to environmental applications

    Design and implementation of a multi-modal sensor with on-chip security

    Get PDF
    With the advancement of technology, wearable devices for fitness tracking, patient monitoring, diagnosis, and disease prevention are finding ways to be woven into modern world reality. CMOS sensors are known to be compact, with low power consumption, making them an inseparable part of wireless medical applications and Internet of Things (IoT). Digital/semi-digital output, by the translation of transmitting data into the frequency domain, takes advantages of both the analog and digital world. However, one of the most critical measures of communication, security, is ignored and not considered for fabrication of an integrated chip. With the advancement of Moore\u27s law and the possibility of having a higher number of transistors and more complex circuits, the feasibility of having on-chip security measures is drawing more attention. One of the fundamental means of secure communication is real-time encryption. Encryption/ciphering occurs when we encode a signal or data, and prevents unauthorized parties from reading or understanding this information. Encryption is the process of transmitting sensitive data securely and with privacy. This measure of security is essential since in biomedical devices, the attacker/hacker can endanger users of IoT or wearable sensors (e.g. attacks at implanted biosensors can cause fatal harm to the user). This work develops 1) A low power and compact multi-modal sensor that can measure temperature and impedance with a quasi-digital output and 2) a low power on-chip signal cipher for real-time data transfer

    Integrated circuit & system design for concurrent amperometric and potentiometric wireless electrochemical sensing

    Get PDF
    Complementary Metal-Oxide-Semiconductor (CMOS) biosensor platforms have steadily grown in healthcare and commerial applications. This technology has shown potential in the field of commercial wearable technology, where CMOS sensors aid the development of miniaturised sensors for an improved cost of production and response time. The possibility of utilising wireless power and data transmission techniques for CMOS also allows for the monolithic integration of the communication, power and sensing onto a single chip, which greatly simplifies the post-processing and improves the efficiency of data collection. The ability to concurrently utilise potentiometry and amperometry as an electrochemical technique is explored in this thesis. Potentiometry and amperometry are two of the most common transduction mechanisms for electrochemistry, with their own advantages and disadvantages. Concurrently applying both techniques will allow for real-time calibration of background pH and for improved accuracy of readings. To date, developing circuits for concurrently sensing potentiometry and amperometry has not been explored in the literature. This thesis investigates the possibility of utilising CMOS sensors for wireless potentiometric and amperometric electrochemical sensing. To start with, a review of potentiometry and amperometry is evaluated to understand the key factors behind their operation. A new configuration is proposed whereby the reference electrode for both electrochemistry techniques are shared. This configuration is then compared to both the original configurations to determine any differences in the sensing accuracy through a novel experiment that utilises hydrogen peroxide as a measurement analyte. The feasibility of the configuration with the shared reference electrode is proven and utilised as the basis of the electrochemical configuration for the front end circuits. A unique front-end circuit named DAPPER is developed for the shared reference electrode topology. A review of existing architectures for potentiometry and amperometry is evaluated, with a specific focus on low power consumption for wireless applications. In addition, both the electrochemical sensing outputs are mixed into a single output data channel for use with a near-field communication (NFC). This mixing technique is also further analysed in this thesis to understand the errors arising due to various factors. The system is fabricated on TSMC 180nm technology and consumes 28”W. It measures a linear input current range from 250pA - 0.1”W, and an input voltage range of 0.4V - 1V. This circuit is tested and verified for both electrical and electrochemical tests to showcase its feasibility for concurrent measurements. This thesis then provides the integration of wireless blocks into the system for wireless powering and data transmission. This is done through the design of a circuit named SPACEMAN that consists of the concurrent sensing front-end, wireless power blocks, data transmission, as well as a state machine that allows for the circuit to switch between modes: potentiometry only, amperometry only, concurrent sensing and none. The states are switched through re-booting the circuit. The core size of the electronics is 0.41mmÂČ without the coil. The circuit’s wireless powering and data transmission is tested and verified through the use of an external transmitter and a connected printed circuit board (PCB) coil. Finally, the future direction for ongoing work to proceed towards a fully monolithic electrochemical technique is discussed through the next development of a fully integrated coil-on-CMOS system, on-chip electrodes with the electroplating and microfludics, the development of an external transmitter for powering the device and a test platform. The contributions of this thesis aim to formulate a use for wireless electrochemical sensors capable of concurrent measurements for use in wearable devices.Open Acces

    Design of a Cost-Efficient Reconfigurable Pipeline ADC

    Get PDF
    Power budget is very critical in the design of battery-powered implantable biomedical instruments. High speed, high resolution and low power usually cannot be achieved at the same time. Therefore, a tradeoff must be made to compromise every aspect of those features. As the main component of the bioinstrument, high conversion rate, high resolution ADC consumes most of the power. Fortunately, based on the operation modes of the bioinstrument, a reconfigurable ADC can be used to solve this problem. The reconfigurable ADC will operate at 10-bit 40 MSPS for the diagnosis mode and at 8-bit 2.5 MSPS for the monitor mode. The ADC will be completely turned off if no active signal comes from sensors or if an off command is received from the antenna. By turning off the sample hold stage and the first two stages of the pipeline ADC, a significant power saving is achieved. However, the reconfigurable ADC suffers from two drawbacks. First, the leakage signals through the extra off-state switches in the third stage degrade the performance of the data converter. This situation tends to be even worse for high speed and high-resolution applications. An interference elimination technique has been proposed in this work to solve this problem. Simulation results show a significant attenuation of the spurious tones. Moreover, the transistors in the OTA tend to operate in weak inversion region due to the scaling of the bias current. The transistor in subthreshold is very slow due to the small transit frequency. In order to get a better tradeoff between the transconductance efficiency and the transit frequency, reconfigurable OTAs and scalable bias technique are devised to adjust the operating point from weak inversion to moderate inversion. The figure of merit of the reconfigurable ADC is comparable to the previously published conventional pipeline ADCs. For the 10-bit, 40 MSPS mode, the ADC attains a 56.9 dB SNDR for 35.4 mW power consumption. For the 8-bit 2.5 MSPS mode, the ADC attains a 49.2 dB SNDR for 7.9 mW power consumption. The area for the core layout is 1.9 mm2 for a 0.35 micrometer process

    Energy-Efficient Start-Up Dickson Charge Pump for Batteryless Biomedical Implant Devices

    Get PDF
    This paper presents a power management concept for solar energy harvesting power management using an on-chip switched-capacitor (SC) DC-DC converter for biomedical implantable applications. This design eliminates potential reversion losses caused by the switching scheme. It also mitigates the bottom plate loss by employing the charge recycling technique. Moreover, instead of using a single step clock pulse, the two-step adiabatic charge sharing clock helps reduce the energy drawn from the PV cell by 65%. Furthermore, with the help of clock disabler scheme, the power dissipation has been further reduced by disabling the entire start-up charge pump once the desired reference output voltage was reached. However, due to additional circuitry for the clock disabler, there is a tradeoff between power efficiency and power dissipation. The proposed system was implemented and fabricated in a standard 0.18-”m TSMC RF CMOS technology. The proposed converter has achieved a maximum efficiency of 73%

    DESIGN AND IMPLEMENTATION OF ENERGY HARVESTING CIRCUITS FOR MEDICAL DEVICES

    Get PDF
    Technological enhancements in a low-power CMOS process have promoted enhancement of advanced circuit design techniques for sensor related electronic circuits such as wearable and implantable sensor systems as well as wireless sensor nodes (WSNs). In these systems, the powering up the electronic circuits has remained as a major problem because battery technologies are not closely following the technological improvements in semiconductor devices and processes thus limiting the number of sensor electronics modules that can be incorporated in the design of the system. In addition, the traditional batteries can leak which can cause serious health hazards to the patients especially when using implantable sensors. As an alternative solution to prolonging the life of battery or to mitigate serious health problems that can be caused by battery, energy harvesting technique has appeared to be one of the possible solutions to supply power to the sensor electronics. As a result, this technique has been widely studied and researched in recent years. In a conventional sensor system, the accessible space for batteries is limited, which restricts the battery capacity. Therefore, energy harvesting has become an attractive solution for powering the sensor electronics. Power can be scavenged from ambient energy sources such as electromagnetic signal, wind, solar, mechanical vibration, radio frequency (RF), and thermal energy etc. Among these common ambient sources, RF and piezoelectric vibration-based energy scavenging systems have received a great deal of attention because of their ability to be integrated with sensor electronics modules and their moderate available power density. In this research, both RF and piezoelectric vibration-based energy harvesting systems have been studied and implemented in 130 nm standard CMOS process
    • 

    corecore