565 research outputs found

    An Empirical Study Comparing Unobtrusive Physiological Sensors for Stress Detection in Computer Work.

    Get PDF
    Several unobtrusive sensors have been tested in studies to capture physiological reactions to stress in workplace settings. Lab studies tend to focus on assessing sensors during a specific computer task, while in situ studies tend to offer a generalized view of sensors' efficacy for workplace stress monitoring, without discriminating different tasks. Given the variation in workplace computer activities, this study investigates the efficacy of unobtrusive sensors for stress measurement across a variety of tasks. We present a comparison of five physiological measurements obtained in a lab experiment, where participants completed six different computer tasks, while we measured their stress levels using a chest-band (ECG, respiration), a wristband (PPG and EDA), and an emerging thermal imaging method (perinasal perspiration). We found that thermal imaging can detect increased stress for most participants across all tasks, while wrist and chest sensors were less generalizable across tasks and participants. We summarize the costs and benefits of each sensor stream, and show how some computer use scenarios present usability and reliability challenges for stress monitoring with certain physiological sensors. We provide recommendations for researchers and system builders for measuring stress with physiological sensors during workplace computer use

    Textile sensors to measure sweat pH and sweat-rate during exercise

    Get PDF
    Sweat analysis can provide a valuable insight into a person’s well-being. Here we present wearable textile-based sensors that can provide real-time information regarding sweat activity. A pH sensitive dye incorporated into a fabric fluidic system is used to determine sweat pH. To detect the onset of sweat activity a sweat rate sensor is incorporated into a textile substrate. The sensors are integrated into a waistband and controlled by a central unit with wireless connectivity. The use of such sensors for sweat analysis may provide valuable physiological information for applications in sports performance and also in healthcare

    Treat me well : affective and physiological feedback for wheelchair users

    Get PDF
    This work reports a electrocardiograph and skin conductivity hardware architecture, based on E-textile electrodes, attached to a wheelchair for affective and physiological computing. Appropriate conditioning circuits and a microcontroller platform that performs acquisition, primary processing, and communication using Bluetooth were designed and implemented. To increase the accuracy and repeatability of the skin conductivity measuring channel, force measurement sensors were attached to the system certifying measuring contact force on the electrode level. Advanced processing including Rwave peak detector, adaptive filtering and autonomic nervous system analysis based on wavelets transform was designed and implemented on a server. A central design of affective recognition and biofeedback system is described.Fundação para a Ciência e a Tecnologia (FCT

    Physiological sensor.

    Get PDF
    For the purpose of medical diagnosis and research, various physiological signals, such as Photoplethysmograph (PPG), Galvanic Skin Response (GSR) and Skin Temperature (SKT), are measured by different types of medical sensor equipment. However, the sensors are intrusive and the patients must endure some discomfort when encountering these types of medical sensor equipment. These bio sensors also fail to be implemented outside of lab or clinical settings. Recently the development in sensor technology and wireless communication technology have significantly improved the integration of wearable systems, so that we could find new ways to minimize the wearable circuits module, design layers of fabric for wearable system. This thesis documents the successful development of a novel, unobtrusive, low-cost, wrist-worn integrated sensors (PPG, GSR, SKT) system using wireless wearable technology capable of measuring real-time data collection, and monitoring which is important when dealing with treatment and management of many chronic illnesses, neurological disorders, and mental health issues. Examples can include: epileptic seizures, autism spectrum disorder (ASD), depression, drug addiction, and anxiety disorders

    The 2023 wearable photoplethysmography roadmap

    Get PDF
    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology

    Ubiquitous emotion-aware computing

    Get PDF
    Emotions are a crucial element for personal and ubiquitous computing. What to sense and how to sense it, however, remain a challenge. This study explores the rare combination of speech, electrocardiogram, and a revised Self-Assessment Mannequin to assess people’s emotions. 40 people watched 30 International Affective Picture System pictures in either an office or a living-room environment. Additionally, their personality traits neuroticism and extroversion and demographic information (i.e., gender, nationality, and level of education) were recorded. The resulting data were analyzed using both basic emotion categories and the valence--arousal model, which enabled a comparison between both representations. The combination of heart rate variability and three speech measures (i.e., variability of the fundamental frequency of pitch (F0), intensity, and energy) explained 90% (p < .001) of the participants’ experienced valence--arousal, with 88% for valence and 99% for arousal (ps < .001). The six basic emotions could also be discriminated (p < .001), although the explained variance was much lower: 18–20%. Environment (or context), the personality trait neuroticism, and gender proved to be useful when a nuanced assessment of people’s emotions was needed. Taken together, this study provides a significant leap toward robust, generic, and ubiquitous emotion-aware computing

    Interpreting Psychophysiological States Using Unobtrusive Wearable Sensors in Virtual Reality

    Get PDF
    One of the main challenges in the study of human be- havior is to quantitatively assess the participants’ affective states by measuring their psychophysiological signals in ecologically valid conditions. The quality of the acquired data, in fact, is often poor due to artifacts generated by natural interactions such as full body movements and gestures. We created a technology to address this problem. We enhanced the eXperience Induction Machine (XIM), an immersive space we built to conduct experiments on human behavior, with unobtrusive wearable sensors that measure electrocardiogram, breathing rate and electrodermal response. We conducted an empirical validation where participants wearing these sensors were free to move in the XIM space while exposed to a series of visual stimuli taken from the International Affective Picture System (IAPS). Our main result consists in the quan- titative estimation of the arousal range of the affective stimuli through the analysis of participants’ psychophysiological states. Taken together, our findings show that the XIM constitutes a novel tool to study human behavior in life-like conditions

    Continuous assessment of epileptic seizures with wrist-worn biosensors

    Get PDF
    Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2011.Cataloged from PDF version of thesis.Includes bibliographical references (p. 145-159).Epilepsy is a neurological disorder characterized predominantly by an enduring predisposition to generate epileptic seizures. The apprehension about injury, or even death, resulting from a seizure often overshadows the lives of those unable to achieve complete seizure control. Moreover, the risk of sudden death in people with epilepsy is 24 times higher compared to the general population and the pathophysiology of sudden unexpected death in epilepsy (SUDEP) remains unclear. This thesis describes the development of a wearable electrodermal activity (EDA) and accelerometry (ACM) biosensor, and demonstrates its clinical utility in the assessment of epileptic seizures. The first section presents the development of a wrist-worn sensor that can provide comfortable and continuous measurements of EDA, a sensitive index of sympathetic activity, and ACM over extensive periods of time. The wearable biosensor achieved high correlations with a Food and Drug Administration (FDA) approved system for the measurement of EDA during various classic arousal experiments. This device offers the unprecedented ability to perform comfortable, long-term, and in situ assessment of EDA and ACM. The second section describes the autonomic alterations that accompany epileptic seizures uncovered using the wearable EDA biosensor and time-frequency mapping of heart rate variability. We observed that the post-ictal period was characterized by a surge in sympathetic sudomotor and cardiac activity coinciding with vagal withdrawal and impaired reactivation. The impact of autonomic dysregulation was more pronounced after generalized tonic-clonic seizures compared to complex partial seizures. Importantly, we found that the intensity of both sympathetic activation and parasympathetic suppression increased approximately linearly with duration of post-ictal EEG suppression, a possible marker for the risk of SUDEP. These results highlight a critical window of post-ictal autonomic dysregulation that may be relevant in the pathogenesis of SUDEP and hint at the possibility for assessment of SUDEP risk by autonomic biomarkers. Lastly, this thesis presents a novel algorithm for generalized tonic-clonic seizure detection with the use of EDA and ACM. The algorithm was tested on 4213 hours (176 days) of recordings from 80 patients containing a wide range of ordinary daily activities and detected 15/16 (94%) tonic-clonic seizures with a low rate of false alarms (<; 1 per 24 h). It is anticipated that the proposed wearable biosensor and seizure detection algorithm will provide an ambulatory seizure alarm and improve the quality of life of patients with uncontrolled tonic-clonic seizures.by Ming-Zher Poh.Ph.D

    Detecting driver fatigue using heart rate variability: A systematic review

    Get PDF
    Driver fatigue detection systems have potential to improve road safety by preventing crashes and saving lives. Conventional driver monitoring systems based on driving performance and facial features may be challenged by the application of automated driving systems. This limitation could potentially be overcome by monitoring systems based on physiological measurements. Heart rate variability (HRV) is a physiological marker of interest for detecting driver fatigue that can be measured during real life driving. This systematic review investigates the relationship between HRV measures and driver fatigue, as well as the performance of HRV based fatigue detection systems. With the applied eligibility criteria, 18 articles were identified in this review. Inconsistent results can be found within the studies that investigated differences of HRV measures between alert and fatigued drivers. For studies that developed HRV based fatigue detection systems, the detection performance showed a large variation, where the detection accuracy ranged from 44% to 100%. The inconsistency and variation of the results can be caused by differences in several key aspects in the study designs. Progress in this field is needed to determine the relationship between HRV and different fatigue causal factors and its connection to driver performance. To be deployed, HRV-based fatigue detection systems need to be thoroughly tested in real life conditions with good coverage of relevant driving scenarios and a sufficient number of participants
    corecore