    An Energy-Efficient, Dynamic Voltage Scaling Neural Stimulator for a Proprioceptive Prosthesis

    Get PDF
    Accepted versio

    Development and modelling of a versatile active micro-electrode array for high density in-vivo and in-vitro neural signal investigation

    Get PDF
    The electrophysiological observation of neurological cells has allowed much knowledge to be gathered regarding how living organisms are believed to acquire and process sensation. Although much has been learned about neurons in isolation, there is much more to be discovered in how these neurons communicate within large networks. The challenges of measuring neurological networks at the scale, density and chronic level of non invasiveness required to observe neurological processing and decision making are manifold, however methods have been suggested that have allowed small scale networks to be observed using arrays of micro-fabricated electrodes. These arrays transduce ionic perturbations local to the cell membrane in the extracellular fluid into small electrical signals within the metal that may be measured. A device was designed for optimal electrical matching to the electrode interface and maximal signal preservation of the received extracellular neural signals. Design parameters were developed from electrophysiological computer simulations and experimentally obtained empirical models of the electrode-electrolyte interface. From this information, a novel interface based signal filtering method was developed that enabled high density amplifier interface circuitry to be realised. A novel prototype monolithic active electrode was developed using CMOS microfabrication technology. The device uses the top metallization of a selected process to form the electrode substrate and compact amplification circuitry fabricated directly beneath the electrode to amplify and separate the neural signal from the baseline offsets and noise of the electrode interface. The signal is then buffered for high speed sampling and switched signal routing. Prototype 16 and 256 active electrode array with custom support circuitry is presented at the layout stage for a 20 μm diameter 100 μm pitch electrode array. Each device consumes 26.4 μW of power and contributes 4.509 μV (rms) of noise to the received signal over a controlled bandwidth of 10 Hz - 5 kHz. The research has provided a fundamental insight into the challenges of high density neural network observation, both in the passive and the active manner. The thesis concludes that power consumption is the fundamental limiting factor of high density integrated MEA circuitry; low power dissipation being crucial for the existence of the surface adhered cells under measurement. With transistor sizing, noise and signal slewing each being inversely proportional to the dc supply current and the large power requirements of desirable ancillary circuitry such as analogue-to-digital converters, a situation of compromise is approached that must be carefully considered for specific application design

    Design and Implementation of a Passive Neurostimulator with Wireless Resonance-Coupled Power Delivery and Demonstration on Frog Sciatic Nerve and Gastrocnemius Muscle

    Get PDF
    The thesis presented has four goals: to perform a comprehensive literature review on current neurostimulator technology; to outline the current issues with the state-of-the-art; to provide a neurostimulator design that solves these issues, and to characterize the design and demonstrate its neurostimulation features. The literature review describes the physiology of a neuron, and then proceeds to outline neural interfaces and neurostimulators. The neurostimulator design process is then outlined and current requirements in the field are described. The novel neurostimulator circuit that implements a solution that has wireless capability, passive control, and small size is outlined and characterized. The circuit is demonstrated to operate wirelessly with a resonance-coupled multi-channel implementation, and is shown powering LEDs. The circuit was then fabricated in a miniature implementation which utilized a 10 x 20 x 3 mm&179 antenna, and occupied a volume approximating 1 cm&179. This miniature circuit is used to stimulate frog sciatic nerve and gastrocnemius muscle in vitro. These demonstrations and characterization show the device is capable of neurostimulation, can operate wirelessly, is controlled passively, and can be implemented in a small size, thus solving the aforementioned neurostimulator requirements. Further work in this area is focused on developing an extensive characterization of the device and the wireless power delivery system, optimizing the circuit design, and performing in vivo experiments with restoration of motor control in injured animals. This device shows promise to provide a comprehensive solution to many application-specific problems in neurostimulation, and be a modular addition to larger neural interface systems

    Methods of magnetic field switching for biomedical and power applications

    Get PDF
    Surrounded by electromagnetic (EM) fields humans continuously interact and utilize EM fields for domestic devices, telecom systems, power systems and different medical applications including MRI (Magnetic Resonance Imaging) and TMS (Transcranial Magnetic Stimulation). During the last century, numerous new electronic devices and technologies have been developed leading to an exponential increase in exposure to Electromagnetic Fields. Although all of these applications are byproducts of Maxwell\u27 experimentation, there are considerable differences in the way they interact with us. In the treatment of noninvasive treatment of the human brain, the majority of the research has been mainly focused on realizing systems that can produce gigantic current and magnetic fields. Transcranial Magnetic Stimulation (TMS) in this application has provided numerous opportunities and possibilities. It has shown more promise in the therapeutic role for treatment of neurological disorders. TMS researchers are working towards improving the technical developmental tools for modeling, and magnetic field generation study for deep body penetration. The development stage of these devices with associated risks in manufacturing, tight medical tolerances, cost and reliability pose important research challenges which are addressed in this research. The objective of this research is to understand, develop and offer alternative methods for the implementation of several magnetic field generators that satisfy the requirement for magnetic field applications in medical, and other fields. This work presents a continual progression of the magnetic field generators from larger scale to small scale with variable energy consumption, high speed, and deployable systems. Additionally challenges and practical designs are presented

    Wireless tools for neuromodulation

    Get PDF
    Epilepsy is a spectrum of diseases characterized by recurrent seizures. It is estimated that 50 million individuals worldwide are affected and 30% of cases are medically refractory or drug resistant. Vagus nerve stimulation (VNS) and deep brain stimulation (DBS) are the only FDA approved device based therapies. Neither therapy offers complete seizure freedom in a majority of users. Novel methodologies are needed to better understand mechanisms and chronic nature of epilepsy. Most tools for neuromodulation in rodents are tethered. The few wireless devices use batteries or are inductively powered. The tether restricts movement, limits behavioral tests, and increases the risk of infection. Batteries are large and heavy with a limited lifetime. Inductive powering suffers from rapid efficiency drops due to alignment mismatches and increased distances. Miniature wireless tools that offer behavioral freedom, data acquisition, and stimulation are needed. This dissertation presents a platform of electrical, optical and radiofrequency (RF) technologies for device based neuromodulation. The platform can be configured with features including: two channels differential recording, one channel electrical stimulation, and one channel optical stimulation. Typical device operation consumes less than 4 mW. The analog front end has a bandwidth of 0.7 Hz - 1 kHz and a gain of 60 dB, and the constant current driver provides biphasic electrical stimulation. For use with optogenetics, the deep brain optical stimulation module provides 27 mW/mm2 of blue light (473 nm) with 21.01 mA. Pairing of stimulating and recording technologies allows closed-loop operation. A wireless powering cage is designed using the resonantly coupled filter energy transfer (RCFET) methodology. RF energy is coupled through magnetic resonance. The cage has a PTE ranging from 1.8-6.28% for a volume of 11 x 11 x 11 in3. This is sufficient to chronically house subjects. The technologies are validated through various in vivo preparations. The tools are designed to study epilepsy, SUDEP, and urinary incontinence but can be configured for other studies. The broad application of these technologies can enable the scientific community to better study chronic diseases and closed-loop therapies

    Telemetry Controlled Brain Machine Interface To Train Cortical Circuits

    Get PDF
    The goal of this dissertation is to document functional reorganization in rat primary somatosensory (SI) cortex. This work proposes to strengthen the interhemispheric connection between homotopic sites in forelimb barrel cortex (FBC) through intracortical microstimulation (ICMS) and induce functional reorganization whereby neurons in the FBC respond to new input from the ipsilateral forelimb. Furthermore, a wireless microstimulation and recording device was developed for producing enhancement and functional reorganization of cortical circuits in FBC. The goal of Experiment One was to test the hypothesis that layer V neurons projected to homotopic sites in contralateral layer V FBC. Retrograde or anterograde neuronal tracer injections were made to characterize the distribution of callosal projecting neurons in contralateral SI that terminate in layer VFBC and where layer V callosal projecting neurons terminate in contralateral SI. The results showed a differential pattern of interhemispheric connectivity between homotopic forelimb representations in layer V FBC. The goal of Experiment Two was to test the hypothesis that ICMS enhances the interhemispheric pathway and leads to functional reorganization. ICMS was delivered in vivo to the interhemispheric pathway between homotopic layer V barrel cortices and multiunit recordings were made to assess changes in firing rate. The results showed ICMS strengthens interhemispheric connectivity and leads to functional reorganization in rat FBC. The goal of Experiment Three was to develop an interactive telemetry-based neural interface device for the controlled delivery of ICMS and recording response activity in rodent. The device successfully delivered microstimulation to a single electrode in SIand recorded evoked responses from a separate electrode in contralateral SI. Its performance was shown to be comparable to commercial stimulating and recording systems. This system serves as a prototype of a wearable compact device. The data suggest that neurons in rat FBC can be induced to respond to new input from the ipsilateral forelimb by enhancing the interhemispheric pathway with ICMS. An interactive system for the controlled delivery of telemetry-based microstimulation and real-time recordings has been demonstrated in vivo. These studies provide the framework for subsequent studies of interhemispheric pathway enhancement and functional reorganization in freely moving rats

    Simplifying the hardware requirements for fast neural EIT of peripheral nerves

    Get PDF
    OBJECTIVE: The main objective of this study was to assess the feasibility of lowering the hardware requirements for fast neural EIT in order to support the distribution of this technique. Specifically, the feasibility of replacing the commercial modules present in the existing high-end setup with compact and cheap customized circuitry was assessed. APPROACH: Nerve EIT imaging was performed on rat sciatic nerves with both our standard ScouseTom setup and a customized version in which commercial benchtop current sources were replaced by custom circuitry. Electrophysiological data and images collected in the same experimental conditions with the two setups were compared. Data from the customized setup was subject to a down-sampling analysis to simulate the use of a recording module with lower specifications. MAIN RESULTS: Compound action potentials (573±287µV and 487±279µV, p=0.28) and impedance changes (36±14µV and 31±16µV, p=0.49) did not differ significantly when measured using commercial high-end current sources or our custom circuitry, respectively. Images reconstructed from both setups showed neglibile (<1voxel, i.e. 40µm) difference in peak location and a high degree of correlation (R2=0.97). When down-sampling from 24 to 16 bits ADC resolution and from 100KHz to 50KHz sampling frequency, signal-to-noise ratio showed acceptable decrease (<-20%), and no meaningful image quality loss was detected (peak location difference <1voxel, pixel-by-pixel correlation R2=0.99). SIGNIFICANCE: The technology developed for this study greatly reduces the cost and size of a fast neural EIT setup without impacting quality and thus promotes the adoption of this technique by the neuroscience research community

    Data analysis of retinal recordings from multi-electrode arrays under in situ electrical stimulation

    Get PDF
    The development of retinal implants has become an important field of study in recent years, with increasing numbers of people falling victim to legal or physical blindness as a result of retinal damage. Important weaknesses in current retinal implants include a lack of the resolution necessary to give a patient a viable level of visual acuity, question marks over the amount of power and energy required to deliver adequate stimulation, and the removal of eye movements from the analysis of the visual scene. This thesis documents investigations by the author into a new CMOS stimulation and imaging chip with the potential to overcome these difficulties. An overview is given of the testing and characterisation of the componments incorporated in the device to mimic the normal functioning of the human retina. Its application to in situ experimental studies of frog retina is also described, as well as how the data gathered from these experiments enables the optimisation of the geometry of the electrode array through which the device will interface with the retina. Such optimisation is important as the deposit of excess electrical charge and energy can lead to detrimental medical side effects. Avoidance of such side effects is crucial to the realisation of the next generation of retinal implants