4,466 research outputs found
Synchronization of spatiotemporal semiconductor lasers and its application in color image encryption
Optical chaos is a topic of current research characterized by
high-dimensional nonlinearity which is attributed to the delay-induced
dynamics, high bandwidth and easy modular implementation of optical feedback.
In light of these facts, which adds enough confusion and diffusion properties
for secure communications, we explore the synchronization phenomena in
spatiotemporal semiconductor laser systems. The novel system is used in a
two-phase colored image encryption process. The high-dimensional chaotic
attractor generated by the system produces a completely randomized chaotic time
series, which is ideal in the secure encoding of messages. The scheme thus
illustrated is a two-phase encryption method, which provides sufficiently high
confusion and diffusion properties of chaotic cryptosystem employed with unique
data sets of processed chaotic sequences. In this novel method of cryptography,
the chaotic phase masks are represented as images using the chaotic sequences
as the elements of the image. The scheme drastically permutes the positions of
the picture elements. The next additional layer of security further alters the
statistical information of the original image to a great extent along the
three-color planes. The intermediate results during encryption demonstrate the
infeasibility for an unauthorized user to decipher the cipher image. Exhaustive
statistical tests conducted validate that the scheme is robust against noise
and resistant to common attacks due to the double shield of encryption and the
infinite dimensionality of the relevant system of partial differential
equations.Comment: 20 pages, 11 figures; Article in press, Optics Communications (2011
Proceedings of the second "international Traveling Workshop on Interactions between Sparse models and Technology" (iTWIST'14)
The implicit objective of the biennial "international - Traveling Workshop on
Interactions between Sparse models and Technology" (iTWIST) is to foster
collaboration between international scientific teams by disseminating ideas
through both specific oral/poster presentations and free discussions. For its
second edition, the iTWIST workshop took place in the medieval and picturesque
town of Namur in Belgium, from Wednesday August 27th till Friday August 29th,
2014. The workshop was conveniently located in "The Arsenal" building within
walking distance of both hotels and town center. iTWIST'14 has gathered about
70 international participants and has featured 9 invited talks, 10 oral
presentations, and 14 posters on the following themes, all related to the
theory, application and generalization of the "sparsity paradigm":
Sparsity-driven data sensing and processing; Union of low dimensional
subspaces; Beyond linear and convex inverse problem; Matrix/manifold/graph
sensing/processing; Blind inverse problems and dictionary learning; Sparsity
and computational neuroscience; Information theory, geometry and randomness;
Complexity/accuracy tradeoffs in numerical methods; Sparsity? What's next?;
Sparse machine learning and inference.Comment: 69 pages, 24 extended abstracts, iTWIST'14 website:
http://sites.google.com/site/itwist1
Recommended from our members
Cardiac Motion Analysis Based on Optical Flow on Real-Time Three-Dimensional Ultrasound Data
With relatively high frame rates and the ability to acquire volume data sets with a stationary transducer, 3D ultrasound systems, based on matrix phased array transducers, provide valuable three-dimensional information, from which quantitative measures of cardiac function can be extracted. Such analyses require segmentation and visual tracking of the left ventricular endocardial border. Due to the large size of the volumetric data sets, manual tracing of the endocardial border is tedious and impractical for clinical applications. Therefore the development of automatic methods for tracking three-dimensional endocardial motion is essential. In this study, we evaluate a four-dimensional optical flow motion tracking algorithm to determine its capability to follow the endocardial border in three dimensional ultrasound data through time. The four-dimensional optical flow method was implemented using three-dimensional correlation. We tested the algorithm on an experimental open-chest dog data set and a clinical data set acquired with a Philips' iE33 three-dimensional ultrasound machine. Initialized with left ventricular endocardial data points obtained from manual tracing at end-diastole, the algorithm automatically tracked these points frame by frame through the whole cardiac cycle. Finite element surfaces were fitted through the data points obtained by both optical flow tracking and manual tracing by an experienced observer for quantitative comparison of the results. Parameterization of the finite element surfaces was performed and maps displaying relative differences between the manual and semi-automatic methods were compared. The results showed good consistency with less than 10% difference between manual tracing and optical flow estimation on 73% of the entire surface. In addition, the optical flow motion tracking algorithm greatly reduced processing time (about 94% reduction compared to human involvement per cardiac cycle) for analyzing cardiac function in three-dimensional ultrasound data sets. A displacement field was computed from the optical flow output, and a framework for computation of dynamic cardiac information is introduced. The method was applied to a clinical data set from a heart transplant patient and dynamic measurements agreed with known physiology as well as experimental results
Fast parallel algorithms for a broad class of nonlinear variational diffusion approaches
Variational segmentation and nonlinear diffusion approaches have been very active research areas in the fields of image processing and computer vision during the last years. In the present paper, we review recent advances in the development of efficient numerical algorithms for these approaches. The performance of parallel implement at ions of these algorithms on general-purpose hardware is assessed. A mathematically clear connection between variational models and nonlinear diffusion filters is presented that allows to interpret one approach as an approximation of the other, and vice versa. Numerical results confirm that, depending on the parametrization, this approximation can be made quite accurate. Our results provide a perspective for uniform implement at ions of both nonlinear variational models and diffusion filters on parallel architectures
- …