1,915 research outputs found

    A Neural Network Based Optimal Wide Area Control Scheme for a Power System

    Get PDF
    With deregulation of the power industry, many tie lines between control areas are driven to operate near their maximum capacity, especially those serving heavy load centers. Wide area control systems (WACSs) using wide-area or global signals can provide remote auxiliary control signals to local controllers such as automatic voltage regulators, power system stabilizers, etc to damp out inter-area oscillations. This paper presents the design and the DSP implementation of a nonlinear optimal wide area controller based on adaptive critic designs and neural networks for a power system on the real-time digital simulator (RTDSĀ©). The performance of the WACS as a power system stability agent is studied using the Kundur\u27\u27s two area power system example. The WACS provides better damping of power system oscillations under small and large disturbances even with the inclusion of local power system stabilizers

    Stability Analysis of Networked Control in Smart Grids

    Get PDF
    A suitable networked control scheme and its stability analysis framework have been developed for controlling inherent electromechanical oscillatory dynamics observed in power systems. It is assumed that the feedback signals are obtained at locations away from the controller/actuator and transmitted over a communication network with the help of phasor measurement units (PMUs). Within the generic framework of networked control system (NCS), the evolution of power system dynamics and associated control actions through a communication network have been modeled as a hybrid system. The data delivery rate has been modeled as a stochastic process. The closed-loop stability analysis framework has considered the limiting probability of data dropout in computing the stability margin. The contribution is in quantifying allowable data-dropout limit for a specified closed loop performance. The research findings are useful in specifying the requirement of communication infrastructure and protocol for operating future smart grids

    Wide-area monitoring and control of future smart grids

    No full text
    Application of wide-area monitoring and control for future smart grids with substantial wind penetration and advanced network control options through FACTS and HVDC (both point-to-point and multi-terminal) is the subject matter of this thesis. For wide-area monitoring, a novel technique is proposed to characterize the system dynamic response in near real-time in terms of not only damping and frequency but also mode-shape, the latter being critical for corrective control action. Real-time simulation in Opal-RT is carried out to illustrate the effectiveness and practical feasibility of the proposed approach. Potential problem with wide-area closed-loop continuous control using FACTS devices due to continuously time-varying latency is addressed through the proposed modification of the traditional phasor POD concept introduced by ABB. Adverse impact of limited bandwidth availability due to networked communication is established and a solution using an observer at the PMU location has been demonstrated. Impact of wind penetration on the system dynamic performance has been analyzed along with effectiveness of damping control through proper coordination of wind farms and HVDC links. For multi-terminal HVDC (MTDC) grids the critical issue of autonomous power sharing among the converter stations following a contingency (e.g. converter outage) is addressed. Use of a power-voltage droop in the DC link voltage control loops using remote voltage feedback is shown to yield proper distribution of power mismatch according to the converter ratings while use of local voltages turns out to be unsatisfactory. A novel scheme for adapting the droop coefficients to share the burden according to the available headroom of each converter station is also studied. The effectiveness of the proposed approaches is illustrated through detailed frequency domain analysis and extensive time-domain simulation results on different test systems

    Grid-Connected Renewable Energy Sources

    Get PDF
    The use of renewable energy sources (RESs) is a need of global society. This editorial, and its associated Special Issue ā€œGrid-Connected Renewable Energy Sourcesā€, offers a compilation of some of the recent advances in the analysis of current power systems that are composed after the high penetration of distributed generation (DG) with different RESs. The focus is on both new control configurations and on novel methodologies for the optimal placement and sizing of DG. The eleven accepted papers certainly provide a good contribution to control deployments and methodologies for the allocation and sizing of DG

    Measurement-Based Monitoring and Control in Power Systems with High Renewable Penetrations

    Get PDF
    Power systems are experiencing rapid changes in their generation mixes because of the increasing integration of inverter-based resources (IBRs) and the retirement of traditional generations. This opens opportunities for a cleaner energy outlook but also poses challenges to the safe operation of the power networks. Enhanced monitoring and control based on the increasingly available measurements are essential in assisting stable operation and effective planning for these evolving systems. First, awareness of the evolving dynamic characteristics is quintessential for secure operation and corrective planning. A quantified monitoring study that keeps track of the inertial response and primary frequency response is conducted on the Eastern Interconnection (EI) for the past decade with field data. Whereas the inertia declined by at least 10%, the primary frequency response experienced an unexpected increase. The findings unveiled in the trending analysis also led to an improved event MW size estimation method, as well as discussions about regional dynamics. Experiencing a faster and deeper renewable integration, the Continental Europe Synchronous Area (CESA) system has been threatened by more frequent occurrences of inter-area oscillations during light-load high-renewable periods. A measurement-based oscillation damping control scheme is proposed for CESA with reduced reliance on system models. The design, implementation, and hardware-in-the-loop (HIL) testing of the controller are discussed in detail. Despite the challenges, the increasing presence of IBRs also brings opportunities for fast and efficient controls. Together with synchronized measurement, IBRs have the potential to flexibly complement traditional frequency and voltage control schemes for improved frequency and voltage recovery. The design, implementation, and HIL testing of the measurement-based frequency and voltage control for the New York State Grid are presented. In addition to the transmission level development, IBRs deployed in distribution networks can also be valuable assets in emergency islanding situations if controlled properly. A power management module is proposed to take advantage of measurements and automatically control the electric boundaries of islanded microgrids for maximized power utilization and improved frequency regulation. The module is designed to be adaptive to arbitrary non-meshed topologies with multiple source locations for increased flexibility, expedited deployment, and reduced cost

    Predicted dynamic performance of a possible AC link between SaskPower north and south systems

    Get PDF
    SaskPower has two separate systems, namely the North and the South systems. The South system contains SaskPower major generation and system load. The North system load is located relatively far from its generation (200 to 300 km). The North system is considered, therefore, to be electrically weaker than the South system. Recently there has been an interest in connecting the two systems to improve the security, stability and reliability of the integrated system. Grid interconnections, however, especially between weak and strong systems, often result in the arising of low-frequency oscillations between the newly connected areas. These oscillations that are termed ā€œinter-area oscillationsā€ exhibit, generally poor damping and can severely restrict system operations by requiring the curtailment of electric power transfers level as an operational measure. There are two options for SaskPower North and South systems interconnection, namely HVAC and HVDC interconnections (tie-lines). This thesis reports the results of digital timedomain simulation studies carried out to investigate the dynamic performance of a proposed 260 km, 138 kV double-circuit HVAC tie-line incorporating a hybrid three-phase Thyristor- Controlled Series Capacitor (TCSC) compensation scheme that would connect the SaskPower North and South systems. The potential problems that might arise due to such an interconnection, namely power flow control and low-frequency oscillations are studied and quantified and a feasible solution is proposed. In this context, the effectiveness of the TCSC compensation scheme in damping power system oscillations in the tie-line is investigated. Time-domain simulations were conducted on the benchmark model using the ElectroMagnetic Transients Program (EMTP-RV). The results of the investigations demonstrate that the proposed HVAC link that incorporates a TCSC compensation scheme is effective in mitigating the low-frequency oscillations between the North and South systems for different system contingencies and operating conditions

    Phasor Measurement Unit Test and Applications for Small Signal Stability Assessment and Improvement of Power System

    Get PDF

    Design and Control of Virtual Synchronous Machine Based Energy Systems

    Get PDF
    Conventionally, the operation and stability of power systems have been governed by the dynamics of large synchronous generators (SGs) which provide the inertial support required to maintain the resilience and stability of the power system. How-ever, the commitment of the UK to drive a zero-carbon economy is accelerating the integration of renewable energy sources (RESs) into the power system. Since the dynamics and operation of RESs diļ¬€ers from SGs, the large-scale integration of RESs will signiļ¬cantly impact the control and stability of the power system.This thesis focuses on the design of grid-friendly control algorithms termed virtual synchronous machines (VSMs), which mimic the desirable characteristics of SGs. Although several VSM topologies have been proposed in literature, most of them require further modiļ¬cations before they can be integrated into the grid. Hence, a novel VSM algorithm for permanent magnet synchronous generator based wind turbines has been proposed in this thesis.The proposed VSM performs seamlessly in all operating modes and enables maxi-mum power point tracking in grid-connected operation (assuming strong grid), load following power generation in islanded mode and fault ride-through during faults. To ensure optimal performance of the VSM in all operating modes, a comprehensive stability analysis of the VSM was performed in the event of small and large per-turbations. The result of the analysis was used to establish design guidelines and operational limits of the VSM.This thesis further evaluates the impact of VSMs on the power systems low-frequency oscillations (LFOs). A detailed two-machine test-bed was developed to analyze the LFOs which exists when VSMs replace SGs. The characteristics of the LFO modes and the dominant states was comprehensively analyzed. The LFO modes which exists in an all-VSM grid was also analyzed. Further, the role of the power system stabilizers in an all-VSM grid was comprehensively evaluated. An IEEE benchmark two-area four-machine system was employed to validate the results of the small-signal analysis.The analysis and time-domain simulations in this thesis were performed in the MAT-LAB/SIMULINK environment

    Study and Analysis of Power System Stability Based on FACT Controller System

    Get PDF
    Energy framework soundness is identified with standards rotational movement and the swing condition administering electromechanical unique conduct. In the exceptional instance of two limited machines, the basis of equivalent territory security can be utilized to ascertain the basic clearing point in the force framework, It is important to look after synchronization, in any case the degree of administration for customers won't be accomplished. This term steadiness signifies "looking after synchronization." This paper is an audit of three kinds of consistent state. The main sort of adjustment, consistent state steadiness clarifies the most extreme consistent state quality and force point chart. The transient solidness clarifies the wavering condition and the idleness steady while dynamic soundness manages the transient security time frame. There are a few different ways to improve framework soundness a portion of the techniques are clarified. Versatile AC Transmission Frameworks (FACTS) Flexible AC Transmission System (FACTS) regulators have been utilized frequently to comprehend the different issues of a non-variable force structure. Versatile AC Transmission Frames or FACTS are devices that permit versatile and dynamic control of intensity outlines. Improving casing respectability has been explored with FACTS regulators. This examination focuses to the upsides of utilizing FACTS apparatuses with the explanation behind improving electric force tire activity. There has been discussion of an execution check for different FACTS regulators

    Power System Dynamics Enhancement Through Phase Unbalanced and Adaptive Control Schemes in Series FACTS devices

    Get PDF
    This thesis presents novel series compensation schemes and adaptive control techniques to enhance power system dynamics through damping Subsynchronous Resonance (SSR) and low-frequency power oscillations: local and inter-area oscillations. Series capacitive compensation of transmission lines is used to improve power transfer capability of the transmission line and is economical compared to the addition of new lines. However, one of the impeding factors for the increased utilization of series capacitive compensation is the potential risk of SSR, where electrical energy is exchanged with turbine-generator shaft systems in a growing manner which can result in shaft damage. Furthermore, the fixed capacitor does not provide controllable reactance and does not aid in the low-frequency oscillations damping. The Flexible AC Transmission System (FACTS) controllers have the flexibility of controlling both real and reactive power which could provide an excellent capability for improving power system dynamics. Several studies have investigated the potential of using this capability in mitigating the low-frequency (electromechanical) as well as the subsynchronous resonance (SSR) oscillations. However, the practical implementations of FACTS devices are very limited due to their high cost. To address this issue, this thesis proposes a new series capacitive compensation concept capable of enhancing power system dynamics. The idea behind the concept is a series capacitive compensation which provides balanced compensation at the power frequency while it provides phase unbalance at other frequencies of oscillations. The compensation scheme is a combination of a single-phase Thyristor Controlled Series Capacitor (TCSC) or Static Synchronous Series Compensator (SSSC) and a fixed series capacitors in series in one phase of the compensated transmission line and fixed capacitors on the other two phases. The proposed scheme is economical compared to a full three-phase FACTS counterpart and improves reliability of the device by reducing number of switching components. The phase unbalance during transients reduces the coupling strength between the mechanical and the electrical system at asynchronous oscillations, thus suppressing the build-up of torsional stresses on the generator shaft systems. The SSR oscillations damping capability of the schemes is validated through detailed time-domain electromagnetic transient simulation studies on the IEEE first and second benchmark models. Furthermore, as the proposed schemes provide controllable reactance through TCSC or SSSC, the supplementary controllers can be implemented to damp low-frequency power oscillations as well. The low-frequency damping capability of the schemes is validated through detail time-domain electromagnetic transient simulation studies on two machines systems connected to a very large system and a three-area, six-machine power system. The simulation studies are carried out using commercially available electromagnetic transient simulation tools (EMTP-RV and PSCAD/EMTDC). An adaptive controller consisting of a robust on-line identifier, namely a robust Recursive Least Square (RLS), and a Pole-Shift (PS) controller is also proposed to provide optimal damping over a wide range of power system operations. The proposed identifier penalizes large estimated errors and smooth-out the change in parameters during large power system disturbances. The PS control is ideal for its robustness and stability conditions. The combination results in a computationally efficient estimator and a controller suitable for optimal control over wider range of operations of a non-linear system such as power system. The most important aspect of the controller is that it can be designed with an approximate linearized model of the complete power system, and does not need to be re-tuned after it is commissioned. The damping capability of such controller is demonstrated through detail studies on a three-area test system and on an IEEE 12-bus test system. Finally, the adaptive control algorithm is developed on a Digital Signal Processing Board, and the performance is experimentally tested using hardware-in-the-loop studies. For this purpose, a Real Time Digital Simulator (RTDS) is used, which is capable of simulating power system in real-time at 50 Āµs simulation time step. The RTDS facilitates the performance evaluation of a controller just like testing on a real power system. The experimental results match closely with the simulation results; which demonstrated the practical applicability of the adaptive controller in power systems. The proposed controller is computationally efficient and simple to implement in DSP hardware
    • ā€¦