283 research outputs found

    Implantable Biomedical Devices

    Get PDF

    ์™„์ „ ์ด์‹ํ˜• ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์„ ์œ„ํ•œ ์—ฐ๊ตฌ

    Get PDF
    ํ•™์œ„๋…ผ๋ฌธ(๋ฐ•์‚ฌ)--์„œ์šธ๋Œ€ํ•™๊ต ๋Œ€ํ•™์› :๊ณต๊ณผ๋Œ€ํ•™ ์ „๊ธฐยท์ •๋ณด๊ณตํ•™๋ถ€,2020. 2. ๊น€์„ฑ์ค€.A visual prosthetic system typically consists of a neural stimulator, which is a surgically implantable device for electrical stimulation intended to restore the partial vision of blind patients, and peripheral external devices including an image sensor, a controller, and a processor. Although several visual prosthetic systems, such as retinal prostheses or retinal implants, have already been commercialized, there are still many issues on them (e.g., substrate materials for implantable units, electrode configurations, the use of external hardware, power supply and data transmission methods, design and fabrication approaches, etc.) to be dealt with for an improved visual prosthetic system. In this dissertation, a totally implantable visual prosthetic system is suggested with four motivations, which are thought to be important, as in the following: 1) simple fabrication of implantable parts, such as micro-sized electrodes and a case, for a neural stimulator based on polymer without semiconductor techniques, 2) multi-polar stimulation for virtual channel generation to overcome a limited number of physical electrodes in a confined space, 3) a new image acquisition strategy using an implantable camera, and 4) power supply as well as data transmission to a neural stimulator without hindering patients various activities. First, polymer materials have been widely used to develop various implantable devices for visual prosthetic systems because of their outstanding advantages including flexibility and applicability to microfabrication, compared with metal, silicon, or ceramic. Most polymer-based implantable devices have been fabricated by the semiconductor technology based on metal deposition and photolithography. This technology provides high accuracy and precision for metal patterning on a polymer substrate. However, the technology is also complicated and time-consuming as it requires masks for photolithography and vacuum for metal deposition as well as huge fabrication facilities. This is the reason why biocompatible cyclic olefin polymer (COP) with low water absorption (<0.01 %) and high light transmission (92 %) was chosen as a new substrate material of an implantable device in this study. Based on COP, simple fabrication process of an implantable device was developed without masks, vacuum, and huge fabrication facilities. COP is characterized by strong adhesion to gold and high ultraviolet (UV) transparency as well. Because of such adhesion and UV transparency, a gold thin film can be thermally laminated on a COP substrate with no adhesion layer and micromachined by a UV laser without damaging the substrate. Using the developed COP-based process, a depth-type microprobe was fabricated first, and its electrochemical and mechanical properties as well as functionality were evaluated by impedance measurements, buckling tests, and in vivo neural signal recording, respectively. Furthermore, the long-term reliability of COP encapsulation formed by the developed process was estimated through leakage current measurements during accelerated aging in saline solution, to show the feasibility of the encapsulation using COP as well. Second, even if stimulation electrodes become sufficiently small, it is demanding to arrange them for precise stimulation on individual neurons due to electrical crosstalk, which is the spatial superposition of electric fields generated by simultaneous stimuli. Hence, an adequate spacing between adjacent electrodes is required, and this causes a limited number of physical electrodes in a confined space such as in the brain or in the retina. To overcome this limitation, many researchers have proposed stimulation strategies using virtual channels, which are intermediate areas with large magnitudes of electric fields between physical electrodes. Such virtual channels can be created by multi-polar stimulation that can combine stimuli output from two or more electrodes at the same time. To produce more delicate stimulation patterns using virtual channels herein, penta-polar stimulation with a grid-shaped arrangement of electrodes was leveraged specially to generate them in two dimensions. This penta-polar stimulation was realized using a custom-designed integrated circuit with five different current sources and surface-type electrodes fabricated by the developed COP-based process. The effectiveness of the penta-polar stimulation was firstly evaluated by focusing electric fields in comparison to mono-polar stimulation. In addition, the distribution of electric fields changed by the penta-polar stimulation, which indicated virtual channel generation, was estimated in accordance with an amplitude ratio between stimuli of the two adjacent electrodes and a distance from them, through both finite element analysis and in vitro evaluation. Third, an implantable camera is herein proposed as a new image acquisition approach capturing real-time images while implanted in the eye, to construct a totally implantable visual prosthetic system. This implantable camera has distinct advantages in that it can provide blind patients with benefits to perform several ordinary activities, such as sleep, shower, or running, while focusing on objects in accordance with natural eye movements. These advantages are impossible to be achieved using a wearing unit such as a glasses-mounted camera used in a conventional partially implantable visual prosthetic system. Moreover, the implantable camera also has a merit of garnering a variety of image information using the complete structure of a camera, compared with a micro-photodiode array of a retinal implant. To fulfill these advantageous features, after having been coated with a biocompatible epoxy to prevent moisture penetration and sealed using a medical-grade silicone elastomer to gain biocompatibility as well as flexibility, the implantable camera was fabricated enough to be inserted into the eye. Its operation was assessed by wireless image acquisition that displayed a processed black and white image. In addition, to estimate reliable wireless communication ranges of the implantable camera in the body, signal-to-noise ratio measurements were conducted while it was covered by an 8-mm-thick biological medium that mimicked an in vivo environment. Lastly, external hardware attached on the body has been generally used in conventional visual prosthetic systems to stably deliver power and data to implanted units and to acquire image signals outside the body. However, there are common problems caused by this external hardware, including functional failure due to external damages, unavailability during sleep, in the shower, or while running or swimming, and cosmetic issues. Especially, an external coil for power and data transmission in a conventional visual prosthetic system is connected to a controller and processor through a wire, which makes the coil more vulnerable to the problems. To solve this issue, a totally implantable neural stimulation system controlled by a handheld remote controller is presented. This handheld remote controller can control a totally implantable stimulator powered by a rechargeable battery through low-power but relatively long-range ZigBee wireless communication. Moreover, two more functions can be performed by the handheld controller for expanded applications; one is percutaneous stimulation, and the other is inductive charging of the rechargeable battery. Additionally, simple switches on the handheld controller enable users to modulate parameters of stimuli like a gamepad. These handheld and user-friendly interfaces can make it easy to use the controller under various circumstances. The functionality of the controller was evaluated in vivo, through percutaneous stimulation and remote control especially for avian navigation, as well as in vitro. Results of both in vivo experiments were compared in order to verify the feasibility of remote control of neural stimulation using the controller. In conclusion, several discussions on results of this study, including the COP-based simple fabrication process, the penta-polar stimulation, the implantable camera, and the multi-functional handheld remote controller, are addressed. Based on these findings and discussions, how the researches in this thesis can be applied to the realization of a totally implantable visual prosthetic system is elucidated at the end of this dissertation.์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์€ ์ผ๋ฐ˜์ ์œผ๋กœ ์‹ค๋ช… ํ™˜์ž๋“ค์˜ ๋ถ€๋ถ„ ์‹œ๋ ฅ์„ ์ „๊ธฐ ์ž๊ทน์œผ๋กœ ํšŒ๋ณต์‹œํ‚ค๊ธฐ ์œ„ํ•˜์—ฌ ์ˆ˜์ˆ ์ ์œผ๋กœ ์ด์‹๋  ์ˆ˜ ์žˆ๋Š” ์žฅ์น˜์ธ ์‹ ๊ฒฝ ์ž๊ทน๊ธฐ์™€ ์ด๋ฏธ์ง€ ์„ผ์„œ ๋˜๋Š” ์ปจํŠธ๋กค๋Ÿฌ, ํ”„๋กœ์„ธ์„œ๋ฅผ ํฌํ•จํ•˜๋Š” ์™ธ๋ถ€์˜ ์ฃผ๋ณ€ ์žฅ์น˜๋“ค๋กœ ๊ตฌ์„ฑ๋œ๋‹ค. ๋ง๋ง‰ ๋ณด์ฒ  ์žฅ์น˜ ๋˜๋Š” ๋ง๋ง‰ ์ž„ํ”Œ๋ž€ํŠธ์™€ ๊ฐ™์ด ๋ช‡๋ช‡ ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์€ ์ด๋ฏธ ์ƒ์šฉํ™” ๋˜์—ˆ์ง€๋งŒ, ์—ฌ์ „ํžˆ ๋” ๋‚˜์€ ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์„ ์œ„ํ•˜์—ฌ ๋‹ค๋ค„์ ธ์•ผ ํ•  ๋งŽ์€ ์ด์Šˆ๋“ค (์˜ˆ๋ฅผ ๋“ค์–ด, ์ด์‹ํ˜• ์žฅ์น˜์˜ ๊ธฐํŒ ๋ฌผ์งˆ, ์ „๊ทน์˜ ๋ฐฐ์—ด, ์™ธ๋ถ€ ํ•˜๋“œ์›จ์–ด์˜ ์‚ฌ์šฉ, ์ „๋ ฅ ๊ณต๊ธ‰ ๋ฐ ๋ฐ์ดํ„ฐ ์ „์†ก ๋ฐฉ๋ฒ•, ์„ค๊ณ„ ๋ฐ ์ œ์ž‘ ๋ฐฉ์‹ ๋“ฑ)์ด ์žˆ๋‹ค. ๋ณธ ํ•™์œ„๋…ผ๋ฌธ์€ ์™„์ „ ์ด์‹ํ˜• ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์„ ์ œ์•ˆํ•˜๋ฉฐ, ์ด๋ฅผ ์œ„ํ•˜์—ฌ ๋‹ค์Œ๊ณผ ๊ฐ™์ด ์ค‘์š”ํ•˜๋‹ค๊ณ  ์ƒ๊ฐ๋˜๋Š” ์ด ๋„ค ๊ฐ€์ง€์˜ ์ด์Šˆ๋“ค๊ณผ ๊ด€๋ จ๋œ ์—ฐ๊ตฌ ๋‚ด์šฉ์„ ๋‹ค๋ฃฌ๋‹ค. 1) ํด๋ฆฌ๋จธ๋ฅผ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•œ ์‹ ๊ฒฝ ์ž๊ทน๊ธฐ์˜ ๋ฏธ์„ธ ์ „๊ทน ๋ฐ ํŒจํ‚ค์ง€์™€ ๊ฐ™์€ ์ด์‹ ๊ฐ€๋Šฅํ•œ ๋ถ€๋ถ„์„ ๋ฐ˜๋„์ฒด ๊ธฐ์ˆ  ์—†์ด ๊ฐ„๋‹จํ•˜๊ฒŒ ์ œ์ž‘ํ•˜๋Š” ๋ฐฉ๋ฒ•๊ณผ 2) ์ œํ•œ๋œ ๊ณต๊ฐ„์—์„œ ์ „๊ทน ๊ฐœ์ˆ˜์˜ ๋ฌผ๋ฆฌ์ ์ธ ํ•œ๊ณ„๋ฅผ ๊ทน๋ณตํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ๊ฐ€์ƒ ์ฑ„๋„์„ ํ˜•์„ฑํ•˜๋Š” ๋‹ค๊ทน์„ฑ ์ž๊ทน ๋ฐฉ์‹, 3) ์ด์‹ํ˜• ์นด๋ฉ”๋ผ๋ฅผ ์‚ฌ์šฉํ•˜๋Š” ์ƒˆ๋กœ์šด ์ด๋ฏธ์ง€ ํš๋“ ์ „๋žต, 4) ํ™˜์ž์˜ ๋‹ค์–‘ํ•œ ํ™œ๋™์„ ๋ฐฉํ•ดํ•˜์ง€ ์•Š์œผ๋ฉด์„œ ์‹ ๊ฒฝ ์ž๊ทน๊ธฐ์— ์ „๋ ฅ์„ ๊ณต๊ธ‰ํ•˜๊ณ  ๋ฐ์ดํ„ฐ๋ฅผ ์ „์†กํ•˜๋Š” ๋ฐฉ๋ฒ•. ์ฒซ์งธ๋กœ, ๊ธˆ์†์ด๋‚˜ ์‹ค๋ฆฌ์ฝ˜, ์„ธ๋ผ๋ฏน์— ๋น„ํ•˜์—ฌ ํด๋ฆฌ๋จธ๋Š” ์œ ์—ฐ์„ฑ ๋ฐ ๋ฏธ์„ธ ์ œ์ž‘์—์˜ ์ ์šฉ ๊ฐ€๋Šฅ์„ฑ์„ ํฌํ•จํ•˜๋Š” ๋‘๋“œ๋Ÿฌ์ง„ ์ด์ ๋“ค์ด ์žˆ๊ธฐ ๋•Œ๋ฌธ์— ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์„ ๊ตฌ์„ฑํ•˜๋Š” ๋‹ค์–‘ํ•œ ์ด์‹ ๊ฐ€๋Šฅํ•œ ๋ถ€๋ถ„๋“ค์— ๋„๋ฆฌ ์ด์šฉ๋˜์—ˆ๋‹ค. ๋Œ€๋ถ€๋ถ„์˜ ํด๋ฆฌ๋จธ ๊ธฐ๋ฐ˜ ์ด์‹ํ˜• ์žฅ์น˜๋“ค์€ ๊ธˆ์† ์ฆ์ฐฉ๊ณผ ์‚ฌ์ง„ ์‹๊ฐ์„ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•˜๋Š” ๋ฐ˜๋„์ฒด ๊ณต์ •์œผ๋กœ ์ œ์ž‘๋˜์—ˆ๋‹ค. ์ด ๊ณต์ •์€ ํด๋ฆฌ๋จธ ๊ธฐํŒ ์œ„์— ๊ธˆ์†์„ ํŒจํ„ฐ๋‹ ํ•˜๋Š” ๋ฐ์— ์žˆ์–ด์„œ ๋†’์€ ์ •ํ™•์„ฑ๊ณผ ์ •๋ฐ€๋„๋ฅผ ์ œ๊ณตํ•œ๋‹ค. ํ•˜์ง€๋งŒ ๊ทธ ๊ณต์ •์€ ๋˜ํ•œ, ์‚ฌ์ง„ ์‹๊ฐ์— ์“ฐ์ด๋Š” ๋งˆ์Šคํฌ์™€ ๊ธˆ์† ์ฆ์ฐฉ์„ ์œ„ํ•œ ์ง„๊ณต๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ์•„์ฃผ ํฐ ๊ณต์ • ์„ค๋น„๋ฅผ ์š”๊ตฌํ•˜๊ธฐ ๋•Œ๋ฌธ์— ์‹œ๊ฐ„ ์†Œ๋ชจ๊ฐ€ ์‹ฌํ•˜๊ณ  ๋ณต์žกํ•˜๋‹ค. ์ด๋Š” ๋ณธ ์—ฐ๊ตฌ์—์„œ ๋‚ฎ์€ ์ˆ˜๋ถ„ ํก์ˆ˜ (<0.01 %)์™€ ๋†’์€ ๋น› ํˆฌ๊ณผ (92 %)๋ฅผ ํŠน์ง•์œผ๋กœ ํ•˜๋Š” ์ƒ์ฒด์ ํ•ฉํ•œ ๊ณ ๋ฆฌํ˜• ์˜ฌ๋ ˆํ•€ ํด๋ฆฌ๋จธ (cyclic olefin polymer, COP)๊ฐ€ ์ด์‹ํ˜• ์žฅ์น˜๋ฅผ ์œ„ํ•œ ์ƒˆ๋กœ์šด ๊ธฐํŒ ๋ฌผ์งˆ๋กœ์จ ์„ ํƒ๋œ ์ด์œ ์ด๋‹ค. COP๋ฅผ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•˜์—ฌ, ๋งˆ์Šคํฌ์™€ ์ง„๊ณต, ํฐ ๊ณต์ • ์„ค๋น„๊ฐ€ ํ•„์š” ์—†์ด ์ด์‹ ๊ฐ€๋Šฅํ•œ ์žฅ์น˜๋ฅผ ๊ฐ„๋‹จํ•˜๊ฒŒ ์ œ์ž‘ํ•˜๋Š” ๊ณต์ •์ด ๊ฐœ๋ฐœ๋˜์—ˆ๋‹ค. COP๋Š” ๊ธˆ๊ณผ์˜ ๊ฐ•ํ•œ ์ ‘ํ•ฉ๊ณผ ์ž์™ธ์„ ์— ๋Œ€ํ•œ ๋†’์€ ํˆฌ๋ช…์„ฑ์„ ๋˜ ๋‹ค๋ฅธ ํŠน์ง•์œผ๋กœ ํ•œ๋‹ค. ์ด์™€ ๊ฐ™์€ ์ ‘ํ•ฉ ํŠน์„ฑ๊ณผ ์ž์™ธ์„  ํˆฌ๋ช…์„ฑ ๋•๋ถ„์—, ๊ธˆ๋ฐ•์€ COP ๊ธฐํŒ์— ๋ณ„๋„์˜ ์ ‘ํ•ฉ์ธต ์—†์ด ์—ด๋กœ ์ ‘ํ•ฉ๋  ์ˆ˜ ์žˆ์„ ๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ๊ทธ ๊ธฐํŒ์— ์†์ƒ์„ ์ฃผ์ง€ ์•Š์œผ๋ฉด์„œ ์ž์™ธ์„  ๋ ˆ์ด์ €๋ฅผ ํ†ตํ•˜์—ฌ ๋ฏธ์„ธํ•˜๊ฒŒ ๊ฐ€๊ณต๋  ์ˆ˜ ์žˆ๋‹ค. ๊ฐœ๋ฐœ๋œ COP ๊ธฐ๋ฐ˜์˜ ๊ณต์ •์„ ์ฒ˜์Œ์œผ๋กœ ์‚ฌ์šฉํ•˜์—ฌ ์นจ์Šตํ˜• ๋ฏธ์„ธ ํ”„๋กœ๋ธŒ๊ฐ€ ์ œ์ž‘๋˜์—ˆ๊ณ , ๊ทธ ์ „๊ธฐํ™”ํ•™์ , ๊ธฐ๊ณ„์  ํŠน์„ฑ๊ณผ ๊ธฐ๋Šฅ์„ฑ์ด ๊ฐ๊ฐ ์ž„ํ”ผ๋˜์Šค ์ธก์ •๊ณผ ๋ฒ„ํด๋ง ํ…Œ์ŠคํŠธ, ์ƒ์ฒด ๋‚ด ์‹ ๊ฒฝ์‹ ํ˜ธ ๊ธฐ๋ก์œผ๋กœ ํ‰๊ฐ€๋˜์—ˆ๋‹ค. ๊ทธ๋ฆฌ๊ณ  COP๋ฅผ ์‚ฌ์šฉํ•œ ๋ฐ€๋ด‰์˜ ๊ฐ€๋Šฅ์„ฑ๋„ ์•Œ์•„๋ณด๊ธฐ ์œ„ํ•˜์—ฌ, ๊ฐœ๋ฐœ๋œ ๊ณต์ •์„ ์‚ฌ์šฉํ•˜์—ฌ ํ˜•์„ฑ๋œ COP ๋ฐ€๋ด‰์˜ ์žฅ๊ธฐ ์•ˆ์ •์„ฑ์ด ์ƒ๋ฆฌ์‹์—ผ์ˆ˜์—์„œ์˜ ๊ฐ€์† ๋…ธํ™” ์ค‘ ๋ˆ„์„ค ์ „๋ฅ˜ ์ธก์ •์„ ํ†ตํ•˜์—ฌ ์ถ”์ •๋˜์—ˆ๋‹ค. ๋‘˜์งธ๋กœ, ์ž๊ทน ์ „๊ทน์˜ ํฌ๊ธฐ๊ฐ€ ์ถฉ๋ถ„ํžˆ ์ž‘์•„์ง„๋‹ค๊ณ  ํ•˜๋”๋ผ๋„, ๋™์‹œ์— ์ถœ๋ ฅ๋˜๋Š” ์ž๊ทน์— ์˜ํ•ด ํ˜•์„ฑ๋˜๋Š” ์ „๊ธฐ์žฅ์˜ ์ค‘์ฒฉ์ธ ํฌ๋กœ์Šค ํ† ํฌ ๋•Œ๋ฌธ์— ๊ฐœ๊ฐœ์˜ ์‹ ๊ฒฝ์„ธํฌ๋ฅผ ์ •๋ฐ€ํ•˜๊ฒŒ ์ž๊ทนํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ์ „๊ทน์„ ๋ฐฐ์—ดํ•˜๋Š” ๊ฒƒ์€ ์•„์ฃผ ์–ด๋ ต๋‹ค. ๋”ฐ๋ผ์„œ ์ธ์ ‘ํ•œ ์ „๊ทน ์‚ฌ์ด์— ์ ๋‹นํ•œ ๊ฐ„๊ฒฉ์ด ํ•„์š”ํ•˜๊ฒŒ ๋˜๊ณ , ์ด๋Š” ํŠนํžˆ ๋‡Œ ๋˜๋Š” ๋ง๋ง‰๊ณผ ๊ฐ™์€ ์ œํ•œ๋œ ๊ณต๊ฐ„์—์„œ ์ „๊ทน ๊ฐœ์ˆ˜์˜ ๋ฌผ๋ฆฌ์ ์ธ ํ•œ๊ณ„๋ฅผ ์•ผ๊ธฐํ•œ๋‹ค. ์ด ํ•œ๊ณ„๋ฅผ ๊ทน๋ณตํ•˜๊ธฐ ์œ„ํ•˜์—ฌ, ๋งŽ์€ ์—ฐ๊ตฌ์ž๋“ค์€ ์‹ค์ œ ์ „๊ทน ์‚ฌ์ด์—์„œ ํฐ ์ „๊ธฐ์žฅ ์„ธ๊ธฐ๋ฅผ ๊ฐ–๋Š” ์ค‘๊ฐ„ ์˜์—ญ์„ ๋‚˜ํƒ€๋‚ด๋Š” ๊ฐ€์ƒ ์ฑ„๋„์„ ์ด์šฉํ•œ ์ž๊ทน ์ „๋žต์„ ์ œ์•ˆํ•˜์˜€๋‹ค. ์ด๋Ÿฌํ•œ ๊ฐ€์ƒ ์ฑ„๋„์€ ๋‘˜ ์ด์ƒ์˜ ์ „๊ทน์—์„œ ๋™์‹œ์— ์ถœ๋ ฅ๋˜๋Š” ์ž๊ทน ํŒŒํ˜•์„ ํ•ฉ์น  ์ˆ˜ ์žˆ๋Š” ๋‹ค๊ทน์„ฑ ์ž๊ทน์— ์˜ํ•˜์—ฌ ํ˜•์„ฑ์ด ๊ฐ€๋Šฅํ•˜๋‹ค. ๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ๊ฐ€์ƒ ์ฑ„๋„์„ ์ด์šฉํ•˜์—ฌ ๋” ์ •๊ตํ•œ ์ž๊ทน ํŒจํ„ด์„ ๋งŒ๋“ค๊ธฐ ์œ„ํ•˜์—ฌ, ํŠนํžˆ 2์ฐจ์›์—์„œ์˜ ๊ฐ€์ƒ ์ฑ„๋„์„ ์ƒ์„ฑํ•˜๊ณ ์ž ๊ฒฉ์žํ˜• ๋ฐฐ์—ด์˜ ์ „๊ทน๊ณผ ํ•จ๊ป˜ 5๊ทน์„ฑ ์ž๊ทน์ด ์‚ฌ์šฉ๋˜์—ˆ๋‹ค. ์ด 5๊ทน์„ฑ ์ž๊ทน์€ ๋‹ค์„ฏ ๊ฐœ์˜ ์„œ๋กœ ๋‹ค๋ฅธ ์ „๋ฅ˜์›์„ ๊ฐ–๋„๋ก ๋งž์ถค ์„ค๊ณ„๋œ ์ง‘์ ํšŒ๋กœ์™€ ๊ฐœ๋ฐœ๋œ COP ๊ธฐ๋ฐ˜ ๊ณต์ •์œผ๋กœ ์ œ์ž‘๋œ ํ‰๋ฉดํ˜• ์ „๊ทน์„ ์‚ฌ์šฉํ•˜์—ฌ ๊ตฌํ˜„๋˜์—ˆ๋‹ค. ๋จผ์ €, 5๊ทน์„ฑ ์ž๊ทน์˜ ํšจ๊ณผ๋ฅผ ํ™•์ธํ•˜๊ณ ์ž ์ด ์ž๊ทน์œผ๋กœ ์ „๊ธฐ์žฅ์„ ํ•œ ๊ณณ์— ๋” ์ง‘์ค‘๋œ ํ˜•ํƒœ๋กœ ๋งŒ๋“ค ์ˆ˜ ์žˆ์Œ์ด ๋‹จ๊ทน์„ฑ ์ž๊ทน๊ณผ์˜ ๋น„๊ต๋ฅผ ํ†ตํ•˜์—ฌ ๊ฒ€์ฆ๋˜์—ˆ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์œ ํ•œ ์š”์†Œ ๋ถ„์„๊ณผ ์ƒ์ฒด ์™ธ ํ‰๊ฐ€ ๋‘˜ ๋ชจ๋‘๋ฅผ ํ†ตํ•˜์—ฌ, 5๊ทน์„ฑ ์ž๊ทน์œผ๋กœ ์ธํ•œ ๊ฐ€์ƒ ์ฑ„๋„ ํ˜•์„ฑ์„ ๋œปํ•˜๋Š” ์ „๊ธฐ์žฅ ๋ถ„ํฌ๊ฐ€ ์ธ์ ‘ํ•œ ๋‘ ์ „๊ทน์—์„œ ๋‚˜์˜ค๋Š” ์ž๊ทน์˜ ์ง„ํญ๋น„์™€ ๊ทธ ์ „๊ทน์œผ๋กœ๋ถ€ํ„ฐ ๋–จ์–ด์ง„ ๊ฑฐ๋ฆฌ์— ๋”ฐ๋ผ ๋ณ€ํ™”๋จ์ด ์ถ”์ •๋˜์—ˆ๋‹ค. ์…‹์งธ๋กœ, ๋ณธ ์—ฐ๊ตฌ์—์„œ๋Š” ๋ˆˆ์— ์ด์‹๋œ ์ฑ„๋กœ ์‹ค์‹œ๊ฐ„ ์ด๋ฏธ์ง€๋ฅผ ์–ป์Œ์œผ๋กœ์จ ์™„์ „ ์ด์‹ํ˜• ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์„ ๊ตฌ์„ฑํ•˜๋Š” ์ด์‹ํ˜• ์นด๋ฉ”๋ผ๋ฅผ ์ƒˆ๋กœ์šด ์ด๋ฏธ์ง€ ํš๋“ ๋ฐฉ์‹์œผ๋กœ์จ ์ œ์•ˆํ•œ๋‹ค. ์ด ์ด์‹ํ˜• ์นด๋ฉ”๋ผ๋Š” ์‹ค๋ช… ํ™˜์ž๋“ค์ด ์ž์—ฐ์Šค๋Ÿฌ์šด ๋ˆˆ์˜ ์›€์ง์ž„์„ ๋”ฐ๋ผ์„œ ๋ฌผ์ฒด๋ฅผ ๋ณผ ์ˆ˜ ์žˆ์œผ๋ฉฐ ์ž ์ด๋‚˜ ์ƒค์›Œ, ๋‹ฌ๋ฆฌ๊ธฐ์™€ ๊ฐ™์€ ์ผ์ƒ์ ์ธ ํ™œ๋™๋“ค์„ ๋ฐฉํ•ด ๋ฐ›์ง€ ์•Š๊ณ  ์ˆ˜ํ–‰ํ•  ์ˆ˜ ์žˆ๋„๋ก ๋•๋Š”๋‹ค๋Š” ์ ์—์„œ ๋…ํŠนํ•œ ์žฅ์ ์„ ๊ฐ–๋Š”๋‹ค. ๊ธฐ์กด์˜ ๋ถ€๋ถ„ ์ด์‹ํ˜• ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์—์„œ ์“ฐ์ด๋Š” ์•ˆ๊ฒฝ ๋ถ€์ฐฉํ˜• ์นด๋ฉ”๋ผ์™€ ๊ฐ™์€ ์ฐฉ์šฉ ์žฅ๋น„๋กœ๋Š” ์ด๋Ÿฌํ•œ ์žฅ์ ๋“ค์„ ์–ป์„ ์ˆ˜ ์—†๋‹ค. ๊ฒŒ๋‹ค๊ฐ€, ์ด์‹ํ˜• ์นด๋ฉ”๋ผ๋Š” ๋ง๋ง‰ ์ž„ํ”Œ๋ž€ํŠธ์˜ ๋ฏธ์„ธ ํฌํ† ๋‹ค์ด์˜ค๋“œ ์–ด๋ ˆ์ด์™€ ๋‹ฌ๋ฆฌ ์™„์ „ํ•œ ์นด๋ฉ”๋ผ ๊ตฌ์กฐ๋ฅผ ์ด์šฉํ•˜์—ฌ ๋‹ค์–‘ํ•œ ์ด๋ฏธ์ง€ ์ •๋ณด๋ฅผ ํš๋“ํ•  ์ˆ˜ ์žˆ๋‹ค๋Š” ์žฅ์ ์„ ๊ฐ–๋Š”๋‹ค. ์ด๋Ÿฌํ•œ ์ด์ ๋“ค์„ ๋‹ฌ์„ฑํ•˜๊ธฐ ์œ„ํ•˜์—ฌ, ๊ทธ ์ด์‹ํ˜• ์นด๋ฉ”๋ผ๋Š” ์ˆ˜๋ถ„ ์นจํˆฌ๋ฅผ ๋ง‰๊ณ ์ž ์ƒ์ฒด์ ํ•ฉํ•œ ์—ํญ์‹œ๋กœ ์ฝ”ํŒ…๋˜์—ˆ๊ณ  ์ƒ์ฒด์ ํ•ฉ์„ฑ๊ณผ ์œ ์—ฐ์„ฑ์„ ์–ป๊ธฐ ์œ„ํ•˜์—ฌ ์˜๋ฃŒ์šฉ ์‹ค๋ฆฌ์ฝ˜ ์—˜๋ผ์Šคํ† ๋จธ๋กœ ๋ฐ€๋ด‰๋œ ํ›„์— ๋ˆˆ์— ์ถฉ๋ถ„ํžˆ ์‚ฝ์ž…๋  ์ˆ˜ ์žˆ๋Š” ํ˜•ํƒœ ๋ฐ ํฌ๊ธฐ๋กœ ์ œ์ž‘๋˜์—ˆ๋‹ค. ์ด ์žฅ์น˜์˜ ๋™์ž‘์€ ํ‘๋ฐฑ์œผ๋กœ ์ฒ˜๋ฆฌ๋œ ์ด๋ฏธ์ง€๋ฅผ ํ‘œ์‹œํ•˜๋Š” ๋ฌด์„  ์ด๋ฏธ์ง€ ํš๋“์œผ๋กœ ์‹œํ—˜๋˜์—ˆ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ๋ชธ ์•ˆ์—์„œ ์ด์‹ํ˜• ์นด๋ฉ”๋ผ ๊ฐ–๋Š” ์•ˆ์ •์ ์ธ ํ†ต์‹  ๊ฑฐ๋ฆฌ๋ฅผ ์ธก์ •ํ•˜๊ธฐ ์œ„ํ•˜์—ฌ, ์žฅ์น˜๊ฐ€ ์ƒ์ฒด ๋‚ด ํ™˜๊ฒฝ์„ ๋ชจ์‚ฌํ•˜๊ธฐ ์œ„ํ•œ 8 mm ๋‘๊ป˜์˜ ์ƒ์ฒด ๋ฌผ์งˆ๋กœ ๋ฎ์ธ ์ƒํƒœ์—์„œ ๊ทธ ์žฅ์น˜์˜ ์‹ ํ˜ธ ๋Œ€ ์žก์Œ๋น„๊ฐ€ ์ธก์ •๋˜์—ˆ๋‹ค. ๋งˆ์ง€๋ง‰์œผ๋กœ, ๊ธฐ์กด์˜ ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์—์„œ ๋ชธ์— ๋ถ€์ฐฉ๋œ ํ˜•ํƒœ์˜ ์™ธ๋ถ€ ํ•˜๋“œ์›จ์–ด๋Š” ์ด์‹๋œ ์žฅ์น˜์— ์ „๋ ฅ๊ณผ ๋ฐ์ดํ„ฐ๋ฅผ ์•ˆ์ •์ ์œผ๋กœ ์ „๋‹ฌํ•˜๊ณ  ์ด๋ฏธ์ง€ ์‹ ํ˜ธ๋ฅผ ์ˆ˜์ง‘ํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ์ผ๋ฐ˜์ ์œผ๋กœ ์‚ฌ์šฉ๋˜์—ˆ๋‹ค. ๊ทธ๋Ÿผ์—๋„ ๋ถˆ๊ตฌํ•˜๊ณ , ์ด๋Ÿฌํ•œ ํ•˜๋“œ์›จ์–ด๋Š” ์™ธ๋ถ€๋กœ๋ถ€ํ„ฐ์˜ ์†์ƒ์œผ๋กœ ์ธํ•œ ๊ธฐ๋Šฅ์ ์ธ ๊ฒฐํ•จ๊ณผ ์ˆ˜๋ฉด ๋ฐ ์ƒค์›Œ, ๋‹ฌ๋ฆฌ๊ธฐ, ์ˆ˜์˜ ํ™œ๋™ ์ค‘ ์ด์šฉ ๋ถˆ๊ฐ€๋Šฅ์„ฑ, ์™ธํ˜•์ ์ธ ์ด์Šˆ ๋“ฑ์„ ํฌํ•จํ•˜๋Š” ๊ณตํ†ต์ ์ธ ๋ฌธ์ œ๋“ค์„ ์•ผ๊ธฐํ•œ๋‹ค. ์ „๋ ฅ ๋ฐ ๋ฐ์ดํ„ฐ ์ „์†ก์„ ์œ„ํ•œ ์™ธ๋ถ€ ์ฝ”์ผ์€ ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์—์„œ ์ปจํŠธ๋กค๋Ÿฌ์™€ ํ”„๋กœ์„ธ์„œ์— ์œ ์„ ์œผ๋กœ ์—ฐ๊ฒฐ๋˜๊ณ , ์ด๋Ÿฌํ•œ ์—ฐ๊ฒฐ์€ ๊ทธ ์ฝ”์ผ์ด ์•ž์„œ ์–ธ๊ธ‰๋œ ๋ฌธ์ œ๋“ค์— ํŠนํžˆ ์ทจ์•ฝํ•˜๊ฒŒ ๋งŒ๋“ ๋‹ค. ์ด๋Ÿฌํ•œ ์ด์Šˆ๋ฅผ ํ•ด๊ฒฐํ•˜๊ณ ์ž, ํœด๋Œ€์šฉ ๋ฌด์„  ์ปจํŠธ๋กค๋Ÿฌ๋กœ ์ œ์–ด๋˜๋Š” ์™„์ „ ์ด์‹ํ˜• ์‹ ๊ฒฝ ์ž๊ทน ์‹œ์Šคํ…œ์ด ์ œ์•ˆ๋œ๋‹ค. ์ด ํœด๋Œ€์šฉ ๋ฌด์„  ์ปจํŠธ๋กค๋Ÿฌ๋Š” ์ €์ „๋ ฅ์ด์ง€๋งŒ ๋น„๊ต์  ์žฅ๊ฑฐ๋ฆฌ ํ†ต์‹ ์ด ๊ฐ€๋Šฅํ•œ ์ง๋น„ (ZigBee) ๋ฌด์„  ํ†ต์‹ ์„ ํ†ตํ•˜์—ฌ ์žฌ์ถฉ์ „ ๊ฐ€๋Šฅํ•œ ๋ฐฐํ„ฐ๋ฆฌ๋กœ ๋™์ž‘ํ•˜๋Š” ์™„์ „ ์ด์‹ํ˜• ์ž๊ทน๊ธฐ๋ฅผ ์ œ์–ดํ•  ์ˆ˜ ์žˆ๋‹ค. ์ด ์™ธ์—๋„, ์ด ํœด๋Œ€์šฉ ์ปจํŠธ๋กค๋Ÿฌ๋ฅผ ์‚ฌ์šฉํ•˜๋ฉด ํญ๋„“์€ ์‘์šฉ์„ ์œ„ํ•œ ๋‘ ๊ฐ€์ง€ ๊ธฐ๋Šฅ์„ ์ถ”๊ฐ€๋กœ ์ˆ˜ํ–‰ํ•  ์ˆ˜ ์žˆ๋‹ค. ํ•˜๋‚˜๋Š” ์œ ์„  ๊ฒฝํ”ผ ์ž๊ทน์ด๋ฉฐ, ๋‹ค๋ฅธ ํ•˜๋‚˜๋Š” ์žฌ์ถฉ์ „ ๊ฐ€๋Šฅํ•œ ๋ฐฐํ„ฐ๋ฆฌ์˜ ์œ ๋„ ์ถฉ์ „ ๊ธฐ๋Šฅ์ด๋‹ค. ๋˜ํ•œ, ์ด ํœด๋Œ€์šฉ ์ปจํŠธ๋กค๋Ÿฌ์˜ ๊ฐ„๋‹จํ•œ ์Šค์œ„์น˜๋ฅผ ์‚ฌ์šฉํ•˜๋ฉด ์‚ฌ์šฉ์ž๋Š” ๊ฒŒ์ž„ํŒจ๋“œ์™€ ๊ฐ™์ด ์ž๊ทน ํŒŒ๋ผ๋ฏธํ„ฐ๋ฅผ ์‰ฝ๊ฒŒ ์กฐ์ ˆํ•  ์ˆ˜ ์žˆ๋‹ค. ์ด๋Ÿฌํ•œ ํœด๋Œ€ ๊ฐ€๋Šฅํ•˜๊ณ  ์‚ฌ์šฉ์ž ์นœํ™”์ ์ธ ์ธํ„ฐํŽ˜์ด์Šค๋ฅผ ํ†ตํ•ด ๋‹ค์–‘ํ•œ ์ƒํ™ฉ์—์„œ ๊ทธ ์ปจํŠธ๋กค๋Ÿฌ๋ฅผ ์‰ฝ๊ฒŒ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ๋‹ค. ๊ทธ ์ปจํŠธ๋กค๋Ÿฌ์˜ ๊ธฐ๋Šฅ์€ ์ƒ์ฒด ์™ธ ํ‰๊ฐ€๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ์กฐ๋ฅ˜์˜ ์›€์ง์ž„ ์ œ์–ด๋ฅผ ์œ„ํ•œ ์œ ์„  ๊ฒฝํ”ผ ์ž๊ทน ๋ฐ ์›๊ฒฉ ์ œ์–ด๋ฅผ ํ†ตํ•ด ์ƒ์ฒด ๋‚ด์—์„œ๋„ ํ‰๊ฐ€๋˜์—ˆ๋‹ค. ๋˜ํ•œ, ๊ทธ ์ปจํŠธ๋กค๋Ÿฌ๋ฅผ ์‚ฌ์šฉํ•œ ์›๊ฒฉ ์‹ ๊ฒฝ ์ž๊ทน ์ œ์–ด์˜ ์ˆ˜ํ–‰ ๊ฐ€๋Šฅ์„ฑ์„ ๊ฒ€์ฆํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ๋‘ ์ƒ์ฒด ๋‚ด ์‹คํ—˜์˜ ๊ฒฐ๊ณผ๊ฐ€ ์„œ๋กœ ๋น„๊ต๋˜์—ˆ๋‹ค. ๊ฒฐ๋ก ์ ์œผ๋กœ, COP ๊ธฐ๋ฐ˜์˜ ๊ฐ„๋‹จํ•œ ์ œ์ž‘ ๊ณต์ •๊ณผ 5๊ทน์„ฑ ์ž๊ทน, ์ด์‹ํ˜• ์นด๋ฉ”๋ผ, ํœด๋Œ€์šฉ ๋‹ค๊ธฐ๋Šฅ ๋ฌด์„  ์ปจํŠธ๋กค๋Ÿฌ๋ฅผ ํฌํ•จํ•˜๋Š” ์—ฐ๊ตฌ ๊ฒฐ๊ณผ์— ๋Œ€ํ•œ ์—ฌ๋Ÿฌ ๋…ผ์˜๊ฐ€ ์ด๋ฃจ์–ด์ง„๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์ด๋Ÿฌํ•œ ๊ฒฐ๊ณผ์™€ ๊ณ ์ฐฐ์— ๊ธฐ์ดˆํ•˜์—ฌ, ๋ณธ ํ•™์œ„๋…ผ๋ฌธ์˜ ์—ฐ๊ตฌ๊ฐ€ ์™„์ „ ์ด์‹ํ˜• ์‹œ๊ฐ ๋ณด์ฒ  ์‹œ์Šคํ…œ์˜ ๊ตฌํ˜„์— ์–ด๋–ป๊ฒŒ ์ ์šฉ๋  ์ˆ˜ ์žˆ๋Š” ์ง€๊ฐ€ ์ด ๋…ผ๋ฌธ์˜ ๋์—์„œ ์ƒ์„ธํžˆ ์„ค๋ช…๋œ๋‹ค.Abstract ------------------------------------------------------------------ i Contents ---------------------------------------------------------------- vi List of Figures ---------------------------------------------------------- xi List of Tables ----------------------------------------------------------- xx List of Abbreviations ------------------------------------------------ xxii Chapter 1. Introduction --------------------------------------------- 1 1.1. Visual Prosthetic System --------------------------------------- 2 1.1.1. Current Issues ------------------------------------------------- 2 1.1.1.1. Substrate Materials ---------------------------------------- 3 1.1.1.2. Electrode Configurations --------------------------------- 5 1.1.1.3. External Hardware ----------------------------------------- 6 1.1.1.4. Other Issues ------------------------------------------------- 7 1.2. Suggested Visual Prosthetic System ------------------------ 8 1.3. Four Motivations ---------------------------------------------- 10 1.4. Proposed Approaches ---------------------------------------- 11 1.4.1. Cyclic Olefin Polymer (COP) ------------------------------ 11 1.4.2. Penta-Polar Stimulation ----------------------------------- 13 1.4.3. Implantable Camera --------------------------------------- 16 1.4.4. Handheld Remote Controller ---------------------------- 18 1.5. Objectives of this Dissertation ------------------------------ 20 Chapter 2. Materials and Methods ----------------------------- 23 2.1. COP-Based Fabrication and Encapsulation -------------- 24 2.1.1. Overview ----------------------------------------------------- 24 2.1.2. Simple Fabrication Process ------------------------------- 24 2.1.3. Depth-Type Microprobe ---------------------------------- 26 2.1.3.1. Design ----------------------------------------------------- 26 2.1.3.2. Characterization ----------------------------------------- 27 2.1.3.3. In Vivo Neural Signal Recording ---------------------- 30 2.1.4. COP Encapsulation ---------------------------------------- 31 2.1.4.1. In Vitro Reliability Test ---------------------------------- 33 2.2. Penta-Polar Stimulation ------------------------------------- 34 2.2.1. Overview ---------------------------------------------------- 34 2.2.2. Design and Fabrication ----------------------------------- 35 2.2.2.1. Integrated Circuit (IC) Design ------------------------- 35 2.2.2.2. Surface-Type Electrode Fabrication ------------------ 38 2.2.3. Evaluations -------------------------------------------------- 39 2.2.3.1. Focused Electric Field Measurement ---------------- 42 2.2.3.2. Steered Electric Field Measurement ----------------- 42 2.3. Implantable Camera ----------------------------------------- 43 2.3.1. Overview ---------------------------------------------------- 43 2.3.2. Design and Fabrication ----------------------------------- 43 2.3.2.1. Circuit Design -------------------------------------------- 43 2.3.2.2. Wireless Communication Program ------------------ 46 2.3.2.3. Epoxy Coating and Elastomer Sealing -------------- 47 2.3.3. Evaluations ------------------------------------------------- 50 2.3.3.1. Wireless Image Acquisition --------------------------- 50 2.3.3.2. Signal-to-Noise Ratio (SNR) Measurement -------- 52 2.4. Multi-Functional Handheld Remote Controller --------- 53 2.4.1. Overview ---------------------------------------------------- 53 2.4.2. Design and Fabrication ----------------------------------- 53 2.4.2.1. Hardware Description ---------------------------------- 53 2.4.2.2. Software Description ----------------------------------- 57 2.4.3. Evaluations -------------------------------------------------- 57 2.4.3.1. In Vitro Evaluation -------------------------------------- 57 2.4.3.2. In Vivo Evaluation --------------------------------------- 59 Chapter 3. Results ------------------------------------------------- 61 3.1. COP-Based Fabrication and Encapsulation ------------- 62 3.1.1. Fabricated Depth-Type Microprobe ------------------- 62 3.1.1.1. Electrochemical Impedance -------------------------- 63 3.1.1.2. Mechanical Characteristics --------------------------- 64 3.1.1.3. In Vivo Neural Signal Recording --------------------- 66 3.1.2. COP Encapsulation --------------------------------------- 68 3.1.2.1. In Vitro Reliability Test --------------------------------- 68 3.2. Penta-Polar Stimulation ------------------------------------ 70 3.2.1. Fabricated IC and Surface-Type Electrodes ---------- 70 3.2.2. Evaluations ------------------------------------------------- 73 3.2.2.1. Focused Electric Field Measurement --------------- 73 3.2.2.2. Steered Electric Field Measurement ---------------- 75 3.3. Implantable Camera ---------------------------------------- 76 3.3.1. Fabricated Implantable Camera ----------------------- 76 3.3.2. Evaluations ------------------------------------------------ 77 3.3.2.1. Wireless Image Acquisition -------------------------- 77 3.3.2.2. SNR Measurement ------------------------------------ 78 3.4. Multi-Functional Handheld Remote Controller ------- 80 3.4.1. Fabricated Remote Controller ------------------------- 80 3.4.2. Evaluations ------------------------------------------------ 81 3.4.2.1. In Vitro Evaluation ------------------------------------ 81 3.4.2.2. In Vivo Evaluation ------------------------------------- 83 Chapter 4. Discussions ------------------------------------------ 86 4.1. COP-Based Fabrication and Encapsulation ------------ 87 4.1.1. Fabrication Process and Fabricated Devices -------- 87 4.1.2. Encapsulation and Optical Transparency ------------ 89 4.2. Penta-Polar Stimulation------------------------------------ 99 4.2.1. Designed IC and Electrode Configurations --------- 99 4.2.2. Virtual Channels in Two Dimensions ---------------- 101 4.3. Implantable Camera -------------------------------------- 102 4.3.1. Enhanced Reliability by Epoxy Coating ------------- 106 4.4. Multi-Functional Handheld Remote Controller ------ 107 4.4.1. Brief Discussions of the Two Extra Functions ------ 108 4.5. Totally Implantable Visual Prosthetic System --------- 113 Chapter 5. Conclusion ------------------------------------------ 117 References -------------------------------------------------------- 121 Supplements ------------------------------------------------------ 133 ๊ตญ๋ฌธ ์ดˆ๋ก ----------------------------------------------------------- 143Docto

    Wireless body sensor networks for health-monitoring applications

    Get PDF
    This is an author-created, un-copyedited version of an article accepted for publication in Physiological Measurement. The publisher is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0967-3334/29/11/R01

    Recent Advances in Neural Recording Microsystems

    Get PDF
    The accelerating pace of research in neuroscience has created a considerable demand for neural interfacing microsystems capable of monitoring the activity of large groups of neurons. These emerging tools have revealed a tremendous potential for the advancement of knowledge in brain research and for the development of useful clinical applications. They can extract the relevant control signals directly from the brain enabling individuals with severe disabilities to communicate their intentions to other devices, like computers or various prostheses. Such microsystems are self-contained devices composed of a neural probe attached with an integrated circuit for extracting neural signals from multiple channels, and transferring the data outside the body. The greatest challenge facing development of such emerging devices into viable clinical systems involves addressing their small form factor and low-power consumption constraints, while providing superior resolution. In this paper, we survey the recent progress in the design and the implementation of multi-channel neural recording Microsystems, with particular emphasis on the design of recording and telemetry electronics. An overview of the numerous neural signal modalities is given and the existing microsystem topologies are covered. We present energy-efficient sensory circuits to retrieve weak signals from neural probes and we compare them. We cover data management and smart power scheduling approaches, and we review advances in low-power telemetry. Finally, we conclude by summarizing the remaining challenges and by highlighting the emerging trends in the field

    Neuromorphic hardware for somatosensory neuroprostheses

    Get PDF
    In individuals with sensory-motor impairments, missing limb functions can be restored using neuroprosthetic devices that directly interface with the nervous system. However, restoring the natural tactile experience through electrical neural stimulation requires complex encoding strategies. Indeed, they are presently limited in effectively conveying or restoring tactile sensations by bandwidth constraints. Neuromorphic technology, which mimics the natural behavior of neurons and synapses, holds promise for replicating the encoding of natural touch, potentially informing neurostimulation design. In this perspective, we propose that incorporating neuromorphic technologies into neuroprostheses could be an effective approach for developing more natural human-machine interfaces, potentially leading to advancements in device performance, acceptability, and embeddability. We also highlight ongoing challenges and the required actions to facilitate the future integration of these advanced technologies

    Improving the mechanistic study of neuromuscular diseases through the development of a fully wireless and implantable recording device

    Get PDF
    Neuromuscular diseases manifest by a handful of known phenotypes affecting the peripheral nerves, skeletal muscle fibers, and neuromuscular junction. Common signs of these diseases include demyelination, myasthenia, atrophy, and aberrant muscle activityโ€”all of which may be tracked over time using one or more electrophysiological markers. Mice, which are the predominant mammalian model for most human diseases, have been used to study congenital neuromuscular diseases for decades. However, our understanding of the mechanisms underlying these pathologies is still incomplete. This is in part due to the lack of instrumentation available to easily collect longitudinal, in vivo electrophysiological activity from mice. There remains a need for a fully wireless, batteryless, and implantable recording system that can be adapted for a variety of electrophysiological measurements and also enable long-term, continuous data collection in very small animals. To meet this need a miniature, chronically implantable device has been developed that is capable of wirelessly coupling energy from electromagnetic fields while implanted within a body. This device can both record and trigger bioelectric events and may be chronically implanted in rodents as small as mice. This grants investigators the ability to continuously observe electrophysiological changes corresponding to disease progression in a single, freely behaving, untethered animal. The fully wireless closed-loop system is an adaptable solution for a range of long-term mechanistic and diagnostic studies in rodent disease models. Its high level of functionality, adjustable parameters, accessible building blocks, reprogrammable firmware, and modular electrode interface offer flexibility that is distinctive among fully implantable recording or stimulating devices. The key significance of this work is that it has generated novel instrumentation in the form of a fully implantable bioelectric recording device having a much higher level of functionality than any other fully wireless system available for mouse work. This has incidentally led to contributions in the areas of wireless power transfer and neural interfaces for upper-limb prosthesis control. Herein the solution space for wireless power transfer is examined including a close inspection of far-field power transfer to implanted bioelectric sensors. Methods of design and characterization for the iterative development of the device are detailed. Furthermore, its performance and utility in remote bioelectric sensing applications is demonstrated with humans, rats, healthy mice, and mouse models for degenerative neuromuscular and motoneuron diseases

    An efficient telemetry system for restoring sight

    Get PDF
    PhD ThesisThe human nervous system can be damaged as a result of disease or trauma, causing conditions such as Parkinsonโ€™s disease. Most people try pharmaceuticals as a primary method of treatment. However, drugs cannot restore some cases, such as visual disorder. Alternatively, this impairment can be treated with electronic neural prostheses. A retinal prosthesis is an example of that for restoring sight, but it is not efficient and only people with retinal pigmentosa benefit from it. In such treatments, stimulation of the nervous system can be achieved by electrical or optical means. In the latter case, the nerves need to be rendered light sensitive via genetic means (optogenetics). High radiance photonic devices are then required to deliver light to the target tissue. Such optical approaches hold the potential to be more effective while causing less harm to the brain tissue. As these devices are implanted in tissue, wireless means need to be used to communicate with them. For this, IEEE 802.15.6 or Bluetooth protocols at 2.4GHz are potentially compatible with most advanced electronic devices, and are also safe and secure. Also, wireless power delivery can operate the implanted device. In this thesis, a fully wireless and efficient visual cortical stimulator was designed to restore the sight of the blind. This system is likely to address 40% of the causes of blindness. In general, the system can be divided into two parts, hardware and software. Hardware parts include a wireless power transfer design, the communication device, power management, a processor and the control unit, and the 3D design for assembly. The software part contains the image simplification, image compression, data encoding, pulse modulation, and the control system. Real-time video streaming is processed and sent over Bluetooth, and data are received by the LPC4330 six layer implanted board. After retrieving the compressed data, the processed data are again sent to the implanted electrode/optrode to stimulate the brainโ€™s nerve cells

    Advances in Microelectronics for Implantable Medical Devices

    Get PDF
    Implantable medical devices provide therapy to treat numerous health conditions as well as monitoring and diagnosis. Over the years, the development of these devices has seen remarkable progress thanks to tremendous advances in microelectronics, electrode technology, packaging and signal processing techniques. Many of todayโ€™s implantable devices use wireless technology to supply power and provide communication. There are many challenges when creating an implantable device. Issues such as reliable and fast bidirectional data communication, efficient power delivery to the implantable circuits, low noise and low power for the recording part of the system, and delivery of safe stimulation to avoid tissue and electrode damage are some of the challenges faced by the microelectronics circuit designer. This paper provides a review of advances in microelectronics over the last decade or so for implantable medical devices and systems. The focus is on neural recording and stimulation circuits suitable for fabrication in modern silicon process technologies and biotelemetry methods for power and data transfer, with particular emphasis on methods employing radio frequency inductive coupling. The paper concludes by highlighting some of the issues that will drive future research in the field

    Design of Wireless Power Transfer and Data Telemetry System for Biomedical Applications

    Get PDF
    With the advancement of biomedical instrumentation technologies sensor based remote healthcare monitoring system is gaining more attention day by day. In this system wearable and implantable sensors are placed outside or inside of the human body. Certain sensors are needed to be placed inside the human body to acquire the information on the vital physiological phenomena such as glucose, lactate, pH, oxygen, etc. These implantable sensors have associated circuits for sensor signal processing and data transmission. Powering the circuit is always a crucial design issue. Batteries cannot be used in implantable sensors which can come in contact with the blood resulting in serious health risks. An alternate approach is to supply power wirelessly for tether-less and battery- less operation of the circuits.Inductive power transfer is the most common method of wireless power transfer to the implantable sensors. For good inductive coupling, the inductors should have high inductance and high quality factor. But the physical dimensions of the implanted inductors cannot be large due to a number of biomedical constraints. Therefore, there is a need for small sized and high inductance, high quality factor inductors for implantable sensor applications. In this work, design of a multi-spiral solenoidal printed circuit board (PCB) inductor for biomedical application is presented. The targeted frequency for power transfer is 13.56 MHz which is within the license-free industrial, scientific and medical (ISM) band. A figure of merit based optimization technique has been utilized to optimize the PCB inductors. Similar principal is applied to design on-chip inductor which could be a potential solution for further miniaturization of the implantable system. For layered human tissue the optimum frequency of power transfer is 1 GHz for smaller coil size. For this reason, design and optimization of multi-spiral solenoidal integrated inductors for 1 GHz frequency is proposed. Finally, it is demonstrated that the proposed inductors exhibit a better overall performance in comparison with the conventional inductors for biomedical applications
    • โ€ฆ
    corecore