1,057 research outputs found

    New trends in active filters for improving power quality

    Get PDF
    Since their basic compensation principles were proposed around 1970, active filters have been studied by many researchers and engineers aiming to put them into practical applications. Shunt active filters for harmonic compensation with or without reactive power compensation, flicker compensation or voltage regulation have been put on a commercial base in Japan, and their rating or capacity has ranged from 50 kVA to 60 MVA at present. In near future, the term of active filters will cover a much wider sense than that of active filters in the 1970s did. The function of active filters will be expanded from voltage flicker compensation or voltage regulation into power quality improvement for power distribution systems as the capacity of active filters becomes larger. This paper describes present states of the active filters based on state-of-the-art power electronics technology, and their future prospects toward the 21st century, including the personal view and expectation of the author</p

    A comparative study of methods for estimating virtual flux at the point of common coupling in grid connected voltage source converters with LCL filter

    Get PDF
    Grid connected Voltage Source Converters (VSCs) with LCL filters usually have voltage measurements at the filter capacitors, while it can be important to control the active or reactive power injection at the grid-side of the LCL filter, for instance at a Point of Common Coupling (PCC). Synchronization to the PCC voltage can be obtained by Virtual Flux (VF) estimation, which can also allow for voltage sensor-less operation of VSCs. This paper is presenting a comparative evaluation of methods for estimating the VF at the PCC, considering a VSC connected to the grid through an LCL filter with a Proportional Resonant (PR) controller as the inner current control loop. The VF estimation is achieved by using frequency adaptive dual SOGI-QSGs (DSOGI-VF). The Frequency Locked Loop (FLL) is used in order to keep the positive and negative sequence (PNS) VF estimation inherently frequency adaptive. Three different methods are considered for obtaining the capacitor current needed for estimating the VF at the grid side of the LCL filter which are based on fully estimation by using the voltage sensor-less method, by estimating the capacitor current from the measured voltage or by using additional capacitor current sensors. The results have been compared and validated by simulation studies.Peer ReviewedPostprint (author's final draft

    An Elegant Solution Using Hybrid Power Filter to Improve the Line Current Spectrum of Multiphase PWM Locomotive Rectifiers with Load Unbalance

    Get PDF
    Locomotive PWM Rectifiers employed in A.C traction systems represent several megawatts of electrical load. Typically they use multiple rectifiers/converters in parallel in order to secure high power ratings and high frequency operation. The rectifiers are supplied from a single-phase A.C. traction transformer with multiple secondaries of high leakage inductance. The switching instants of the PWM rectifiers are phase shifted and interlaced in order to achieve high ripple current cancellation, assuming that the converter loads are balanced. This would ensure the rectifiers to provide better harmonic performance and also redundancy of operation with multiple units in operation. However, in practice, rectifiers may be closely coupled to a traction inverter supplying an axle or a group of axles and the real power developed will depend upon the traction conditions. Creep and slip can give rise to variations in power and perfect power balance at the rectifiers is an improbable proposition.There is high degree of interest to examine the possibility locomotive systems that degrade gracefully with equipment failure. Failure of one traction inverter would lead to load unbalance for the rectifier modules. Or sometimes, partial failures may result in unbalanced operation which can cause reduced ripple current cancellation and generate switching frequency harmonic current components. This may adversely impact the signalling systems and/or result in over voltage effects due to resonance in the overhead supply system. This paper examines a 4 MW locomotive with three rectifier modules and a device switching frequency of 900 Hz. This results in a 5400 Hz ripple frequency in the mains current. And this paper will consider what may be the most frequently occurring case; that of loss of load in one traction motor due to wheel slip. Current ripple cancellation is partially lost in this case and lower frequency current components can be produced. Traditionally, number of solutions has been employed in the industry like passive filters, active filters etc., for this type of a problem. However, this paper explores an elegant, attractive and economical solution of using hybrid filters in order to achieve a level of acceptable satisfactory harmonic performance and thereby improving the power quality of the rail systems

    A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters

    Get PDF

    Fast Adaptive Robust Differentiator Based Robust-Adaptive Control of Grid-Tied Inverters with a New L Filter Design Method

    Get PDF
    In this research, a new nonlinear and adaptive state feedback controller with a fast-adaptive robust differentiator is presented for grid-tied inverters. All parameters and external disturbances are taken as uncertain in the design of the proposed controller without the disadvantages of singularity and over-parameterization. A robust differentiator based on the second order sliding mode is also developed with a fast-adaptive structure to be able to consider the time derivative of the virtual control input. Unlike the conventional backstepping, the proposed differentiator overcomes the problem of explosion of complexity. In the closed-loop control system, the three phase source currents and direct current (DC) bus voltage are assumed to be available for feedback. Using the Lyapunov stability theory, it is proven that the overall control system has the global asymptotic stability. In addition, a new simple L filter design method based on the total harmonic distortion approach is also proposed. Simulations and experimental results show that the proposed controller assurances drive the tracking errors to zero with better performance, and it is robust against all uncertainties. Moreover, the proposed L filter design method matches the total harmonic distortion (THD) aim in the design with the experimental result

    New trends in active filters for power conditioning

    Get PDF
    Attention has been paid to active filters for power conditioning which provide the following multifunctions: reactive power compensation; harmonic compensation; flicker/imbalance compensation; and voltage regulation. Active filters in a range of 50 kVA-60 MVA have been practically installed in Japan. In the near future, the term “active filters” will have a much wider meaning than it did in the 1970s. For instance, active filters intended for harmonic solutions are expanding their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumers, and harmonic damping throughout power distribution systems. This paper presents the present status of active filters based on state-of-the-art power electronics technology, and their future prospects and directions toward the 21st Century, including the personal views and expectations of the author</p

    Comparative study of TEC for GISTM stations in the Peninsular Malaysia region for the period of January 2011 to December 2012

    Get PDF
    Total Electron Content (TEC) is a fundamental and the most prevalent parameter that affects Global Positioning System (GPS) signals, leading to delays, poor signals or total loss of signals. The gradients in TEC are frequently associated with disturbance in the ionosphere which explains the space weather behavior and indirectly causes inefficient operations of ground and space based Global Navigation Satellite System (GNSS) applications. The role of TEC variability is constructive in space weather prediction as it allows GNSS users to minimize rangerate errors in achieving highly reliable measurements. This paper therefore presents an analysis of the diurnal and seasonal activity dependence of TEC using data obtained from the GPS Ionospheric Scintillation and TEC Monitor (GISTM) at two stations in Peninsular Malaysia which are located at the Langkawi National Observatory, Langkawi, LGKW (06_19’N, 99_51’E) and Universiti Kebangsaan Malaysia, UKM (02_55’N, 101_46’E). Data for the two years (2011 and 2012), were recorded using the NovAtel GSV 4004B GISTM model equipment. Further investigations on a few more stations in the coast of Peninsular Malaysia will strengthen and consolidate the findings of this study

    Comparison of Three-Phase Active Rectifiers For Aircraft Application

    Get PDF
    In aircraft applications, there has been an increasing trend related with the More Electric Aircraft (MEA), which results in rapid rise in the electrical power demand on-board. One of its goals lies in minimizing weight and volume of the electrical subsystem while maintaining good power quality and efficiency. The main purpose of this paper is to present and analyze an electrical design of three-phase Boost rectifier, three-phase Buck rectifier and three-phase Vienna rectifier for 10 kW active rectifiers and compare them in terms of weight, volume, efficiency etc. Moreover, the design is obliged to comply with DO-160 standard for avionic equipment with 230 V AC, 360-800 Hz grid conditions. Even though all proposed solutions satisfy the standard requirements, it will be shown that the Vienna rectifier has the lowest volume and therefore, the better solution overall. However, due to increased number of semiconductors and additional circuitry required for soft start-up, the Buck rectifier would prove to be the safest solution failure-wise

    Optimal Design and Control of Multi-Motor Drive System for Industrial Application

    Get PDF
    In this paper, the topology of the adjustable speed drive with active front end rectifier is considered in terms of application in multi-motor drives. A dynamic model of the rectifier with a coupled LCL filter is presented. A simulation model has been developed for the analysis of multi-motor drive system dynamics and power flow. Based on the simulation model, the functional possibilities of reversible induction motor drive with active front end converter and multiple voltage source inverters on a common DC bus at the motor side are analysed. One example of the application of a complex full regenerative multi-motor drive system on a common DC bus for an industrial crane, implemented with Siemens converters, is shown. The motor and generator mode of operation from the aspect of energy saving as well as the influence of drives on the distribution network from the aspect of higher harmonics and power factors are analysed. Siemens\u27s original software, Starter commissioning tool, for drives configuration and data acquisition is used
    corecore