3,795 research outputs found
A robust similarity measure for volumetric image registration with outliers
Image registration under challenging realistic conditions is a very important area of research. In this paper, we focus on algorithms that seek to densely align two volumetric images according to a global similarity measure. Despite intensive research in this area, there is still a need for similarity measures that are robust to outliers common to many different types of images. For example, medical image data is often corrupted by intensity inhomogeneities and may contain outliers in the form of pathologies. In this paper we propose a global similarity measure that is robust to both intensity inhomogeneities and outliers without requiring prior knowledge of the type of outliers. We combine the normalised gradients of images with the cosine function and show that it is theoretically robust against a very general class of outliers. Experimentally, we verify the robustness of our measures within two distinct algorithms. Firstly, we embed our similarity measures within a proof-of-concept extension of the LucasāKanade algorithm for volumetric data. Finally, we embed our measures within a popular non-rigid alignment framework based on free-form deformations and show it to be robust against both simulated tumours and intensity inhomogeneities
Robust similarity registration technique for volumetric shapes represented by characteristic functions
This paper proposes a novel similarity registration technique for volumetric shapes implicitly represented by their characteristic functions (CFs). Here, the calculation of rotation parameters is considered as a spherical crosscorrelation problem and the solution is therefore found using the standard phase correlation technique facilitated by principal components analysis (PCA).Thus, fast Fourier transform (FFT) is employed to vastly improve efficiency and robustness. Geometric moments are then used for shape scale estimation which is independent from rotation and translation parameters. It is numericallydemonstrated that our registration method is able to handle shapes with various topologies and robust to noise and initial poses. Further validation of our method is performed by registering a lung database
Automated detection of brain abnormalities in neonatal hypoxia ischemic injury from MR images.
We compared the efficacy of three automated brain injury detection methods, namely symmetry-integrated region growing (SIRG), hierarchical region splitting (HRS) and modified watershed segmentation (MWS) in human and animal magnetic resonance imaging (MRI) datasets for the detection of hypoxic ischemic injuries (HIIs). Diffusion weighted imaging (DWI, 1.5T) data from neonatal arterial ischemic stroke (AIS) patients, as well as T2-weighted imaging (T2WI, 11.7T, 4.7T) at seven different time-points (1, 4, 7, 10, 17, 24 and 31 days post HII) in rat-pup model of hypoxic ischemic injury were used to assess the temporal efficacy of our computational approaches. Sensitivity, specificity, and similarity were used as performance metrics based on manual ('gold standard') injury detection to quantify comparisons. When compared to the manual gold standard, automated injury location results from SIRG performed the best in 62% of the data, while 29% for HRS and 9% for MWS. Injury severity detection revealed that SIRG performed the best in 67% cases while 33% for HRS. Prior information is required by HRS and MWS, but not by SIRG. However, SIRG is sensitive to parameter-tuning, while HRS and MWS are not. Among these methods, SIRG performs the best in detecting lesion volumes; HRS is the most robust, while MWS lags behind in both respects
Detail-preserving and Content-aware Variational Multi-view Stereo Reconstruction
Accurate recovery of 3D geometrical surfaces from calibrated 2D multi-view
images is a fundamental yet active research area in computer vision. Despite
the steady progress in multi-view stereo reconstruction, most existing methods
are still limited in recovering fine-scale details and sharp features while
suppressing noises, and may fail in reconstructing regions with few textures.
To address these limitations, this paper presents a Detail-preserving and
Content-aware Variational (DCV) multi-view stereo method, which reconstructs
the 3D surface by alternating between reprojection error minimization and mesh
denoising. In reprojection error minimization, we propose a novel inter-image
similarity measure, which is effective to preserve fine-scale details of the
reconstructed surface and builds a connection between guided image filtering
and image registration. In mesh denoising, we propose a content-aware
-minimization algorithm by adaptively estimating the value and
regularization parameters based on the current input. It is much more promising
in suppressing noise while preserving sharp features than conventional
isotropic mesh smoothing. Experimental results on benchmark datasets
demonstrate that our DCV method is capable of recovering more surface details,
and obtains cleaner and more accurate reconstructions than state-of-the-art
methods. In particular, our method achieves the best results among all
published methods on the Middlebury dino ring and dino sparse ring datasets in
terms of both completeness and accuracy.Comment: 14 pages,16 figures. Submitted to IEEE Transaction on image
processin
Groupwise Multimodal Image Registration using Joint Total Variation
In medical imaging it is common practice to acquire a wide range of
modalities (MRI, CT, PET, etc.), to highlight different structures or
pathologies. As patient movement between scans or scanning session is
unavoidable, registration is often an essential step before any subsequent
image analysis. In this paper, we introduce a cost function based on joint
total variation for such multimodal image registration. This cost function has
the advantage of enabling principled, groupwise alignment of multiple images,
whilst being insensitive to strong intensity non-uniformities. We evaluate our
algorithm on rigidly aligning both simulated and real 3D brain scans. This
validation shows robustness to strong intensity non-uniformities and low
registration errors for CT/PET to MRI alignment. Our implementation is publicly
available at https://github.com/brudfors/coregistration-njtv
Saliency-guided integration of multiple scans
we present a novel method..
PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI
In this paper we present a novel method for the correction of motion
artifacts that are present in fetal Magnetic Resonance Imaging (MRI) scans of
the whole uterus. Contrary to current slice-to-volume registration (SVR)
methods, requiring an inflexible anatomical enclosure of a single investigated
organ, the proposed patch-to-volume reconstruction (PVR) approach is able to
reconstruct a large field of view of non-rigidly deforming structures. It
relaxes rigid motion assumptions by introducing a specific amount of redundant
information that is exploited with parallelized patch-wise optimization,
super-resolution, and automatic outlier rejection. We further describe and
provide an efficient parallel implementation of PVR allowing its execution
within reasonable time on commercially available graphics processing units
(GPU), enabling its use in the clinical practice. We evaluate PVR's
computational overhead compared to standard methods and observe improved
reconstruction accuracy in presence of affine motion artifacts of approximately
30% compared to conventional SVR in synthetic experiments. Furthermore, we have
evaluated our method qualitatively and quantitatively on real fetal MRI data
subject to maternal breathing and sudden fetal movements. We evaluate
peak-signal-to-noise ratio (PSNR), structural similarity index (SSIM), and
cross correlation (CC) with respect to the originally acquired data and provide
a method for visual inspection of reconstruction uncertainty. With these
experiments we demonstrate successful application of PVR motion compensation to
the whole uterus, the human fetus, and the human placenta.Comment: 10 pages, 13 figures, submitted to IEEE Transactions on Medical
Imaging. v2: wadded funders acknowledgements to preprin
Cube-Cut: Vertebral Body Segmentation in MRI-Data through Cubic-Shaped Divergences
In this article, we present a graph-based method using a cubic template for
volumetric segmentation of vertebrae in magnetic resonance imaging (MRI)
acquisitions. The user can define the degree of deviation from a regular cube
via a smoothness value Delta. The Cube-Cut algorithm generates a directed graph
with two terminal nodes (s-t-network), where the nodes of the graph correspond
to a cubic-shaped subset of the image's voxels. The weightings of the graph's
terminal edges, which connect every node with a virtual source s or a virtual
sink t, represent the affinity of a voxel to the vertebra (source) and to the
background (sink). Furthermore, a set of infinite weighted and non-terminal
edges implements the smoothness term. After graph construction, a minimal
s-t-cut is calculated within polynomial computation time, which splits the
nodes into two disjoint units. Subsequently, the segmentation result is
determined out of the source-set. A quantitative evaluation of a C++
implementation of the algorithm resulted in an average Dice Similarity
Coefficient (DSC) of 81.33% and a running time of less than a minute.Comment: 23 figures, 2 tables, 43 references, PLoS ONE 9(4): e9338