1,641 research outputs found

    Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus

    Get PDF
    Long-term fetal heart rate (FHR) monitoring is necessary to ensure that any FHR abnormality, which may appear at any time during pregnancy and labor, can be detected. An ambulatory electrocardiogram (ECG) recorder employing three abdominal surface electrodes has been developed towards achieving such a monitoring. The difficulties encountered in determining the FHR from the maternal abdominal signal are mainly the interference due to the electromyogram and motion artifact, and relatively small amplitude of the fetal ECG compared to that of the maternal. Thus improvement to existing abdominal signal processing algorithm is necessary to increase the percentage of successful monitoring. A real-time algorithm has been developed for the simultaneous measurement of the fetal and maternal heart rates from the abdominal signal. The algorithm is based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima. A filtering technique has been utilized in the proposed algorithm to extract the fetal signal from the maternal abdominal signal. This is an alternative to a previous method which subtracts the maternal complexes from the abdominal signal with a need to overcome the problem of matching a template to the complexes. The proposed algorithm is capable of continuous ambulatory FHR monitoring either off-line, by using recorded signals, or on-line by a clinician during antenatal examination. The performance of the algorithm has been evaluated of the heart rates tracing processed from the abdominal signals. The resulting average accuracy is 83% for the FHR detection. The detection of the FHR from the maternal abdominal signal by the developed algorithm has also been compared with a short-term monitoring commercial instrument IFM-500 for the assessment of the reliability of the algorithm. The performance achieved from the comparison shows non-significant differences of means, low error percentages and linear correlation coefficient. A portable system based on the developed algorithm has the potential for increased percentage of real-time FHR detection thus enabling successful long-term fetal monitoring

    Signal processing methodologies for an acoustic fetal heart rate monitor

    Get PDF
    Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use

    Southwest Research Institute assistance to NASA in biomedical areas of the technology

    Get PDF
    Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface

    A mobile full-time daily system for fetal monitoring

    Get PDF
    The article describes a mobile hardware and software system designed for daily monitoring of the state of fetal and maternal cardiovascular systems. The assessment is carried out by means of recording and further online analysis of acoustic data, obtained from the abdominal surface of a pregnant woman’s body. The components and operating principles of the hardware and software system designed are described. The results of experimental studies aimed at assessing the applicability of a method of acoustic data analysis implemented in the system developed are shown. The results obtained have been compared with the results obtained using cardiotocography

    Fetal movements recording system using accelerometer sensor

    Get PDF
    One of the compelling challenges in modern obstetrics is the monitoring fetal wellbeing. Physicians are gradually becoming cognizant of the relationship between fetal activity, movement, welfare, and future developmental progress. Previous works have developed few accelerometer-based systems to tackle issues related to ultrasound measurement, the provision of remote s1pport and self-managed monitoring of fetal movement during pregnancy. Though, many research questions on the optimal setup in terms of body-worn accelerometers, as well as signal processing and machine learning techniques used to detect fetal movement, are still open. In this work, a new fetal movement system recorder has been proposed. The proposed system has six accelerometer sensors and ARDUINO microcontroller. The device which is interfaced with the MATLAB signal process tool has been designed to record, display and store relevant sets of fetal movements. The sensors are to be placed on the maternal abdomen to record and process physical signals originating from the fetal. Comparison of data recorded from fetal movements with ultrasound and maternal perception technique gave the following results. An accuracy of 59.78%, 85.87%,and 97.83% was achieved using the maternal perception technique, fetal movement recording system, and ultrasound respectively. The findings show that the proposed fetal movement recording system has a better accuracy rate than maternal perception technique, and can be compared with ultrasound

    A WI-FI BASED SMART DATA LOGGER FOR CAPSULE ENDOSCOPY AND MEDICAL APPLICATIONS

    Get PDF
    Wireless capsule endoscopy (WCE) is a non-invasive technology for capturing images of a human digestive system for medical diagnostics purpose. With WCE, the patient swallows a miniature capsule with camera, data processing unit, RF transmitter and batteries. The capsule captures and transmits images wirelessly from inside the human gastrointestinal (GI) tract. The external data logger worn by the patient stores the images and is later on transferred to a computer for presentation and image analysis. In this research, we designed and built a Wi-Fi based, low cost, miniature, versatile wearable data logger. The data logger is used with Wi-Fi enabled smart devices, smart phones and data servers to store and present images captured by capsule. The proposed data logger is designed to work with wireless capsule endoscopy and other biosensors like- temperature and heart rate sensors. The data logger is small enough to carry and conduct daily activities, and the patient do not need to carry traditional bulky data recorder all the time during diagnosis. The doctors can remotely access data and analyze the images from capsule endoscopy using remote access feature of the data logger. Smartphones and tablets have extensive processing power with expandable memory. This research exploits those capabilities to use with wireless capsule endoscopy and medical data logging applications. The application- specific data recorders are replaced by the proposed Wi-Fi data logger and smartphone. The data processing application is distributed on smart devices like smartphone /tablets and data logger. Once data are stored in smart devices, the data can be accessed remotely, distributed to the cloud and shared within networks to enable telemedicine. The data logger can work in both standalone and network mode. In the normal mode of the device, data logger stores medical data locally into a micro Secure Digital card for future download using the universal serial bus to the computer. In network mode, the real-time data is streamed into a smartphone and tablet for further processing and storage. The proposed Wi-Fi based data logger is prototyped in the lab and tested with the capsule hardware developed in our laboratory. The supporting Android app is also developed to collect data from the data logger and present the processed data to the viewer. The PC based software is also developed to access the data recorder and capture and download data from the data logger in real-time remotely. Both in vivo and ex vivo trials using live pig have been conducted to validate the performance of the proposed device

    Real-time signal processing for fetal heart rate monitoring

    Get PDF
    An algorithm based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima has been developed for the simultaneous measurement of the fetal and maternal heart rates from the maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. A microcontroller-based system has been used to implement the algorithm in real-time. A Doppler ultrasound fetal monitor was used for statistical comparison on five volunteers with low risk pregnancies, between 35 and 40 weeks of gestation. Results showed an average percent root mean square difference of 5.32% and linear correlation coefficient from 0.84 to 0.93. The fetal heart rate curves remained inside a 5-beats-per-minute limit relative to the reference ultrasound method for 84.1% of the tim

    Rule based signal processing for ambulatory fetal monitoring

    Get PDF
    An algorithm has been developed for the simultaneous measurement of the fetal and maternal heart rates from the maternal abdominal electrocardiogram during pregnancy and labor. The algorithm is based on digital filtering, adaptive thresholding, statistical properties in the time domain and differencing of local maxima and minima. The technique has been developed through a combination and modification of earlier techniques making it suitable for ambulatory monitoring. Eighteen volunteers at various weeks of gestation were studied for the fetal heart rate detection. The computation complexity is such that the developed algorithm can extract both maternal and fetal heart rates in real-time utilizing a single-lead configuration
    corecore