20,538 research outputs found
Design of a patient-tailored active knee-ankle-foot orthosis to assist the gait of spinal cord injured subjects
—This paper presents the main design steps in the
development of an active knee-ankle-foot orthosis (KAFO)
conceived to assist the gait of incomplete spinal cord injured
(SCI) subjects. The design approach is based on the idea of
modifying the available passive orthoses by adding
adaptable mechatronic modules at the joints. This approach
has resulted in a prototype that has been tested on SCI
patients. The design and control problems found and their
adopted solutions are thoroughly described.Postprint (published version
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
This paper introduces a newly developed gait rehabilitation device. The device, called LOPES, combines a freely translatable and 2-D-actuated pelvis segment with a leg exoskeleton containing three actuated rotational joints: two at the hip and one at the knee. The joints are impedance controlled to allow bidirectional mechanical interaction between the robot and the training subject. Evaluation measurements show that the device allows both a "pa- tient-in-charge" and "robot-in-charge" mode, in which the robot is controlled either to follow or to guide a patient, respectively. Electromyography (EMG) measurements (one subject) on eight important leg muscles, show that free walking in the device strongly resembles free treadmill walking; an indication that the device can offer task-specific gait training. The possibilities and limitations to using the device as gait measurement tool are also shown at the moment position measurements are not accurate enough for inverse-dynamical gait analysis
Feedback Control of an Exoskeleton for Paraplegics: Toward Robustly Stable Hands-free Dynamic Walking
This manuscript presents control of a high-DOF fully actuated lower-limb
exoskeleton for paraplegic individuals. The key novelty is the ability for the
user to walk without the use of crutches or other external means of
stabilization. We harness the power of modern optimization techniques and
supervised machine learning to develop a smooth feedback control policy that
provides robust velocity regulation and perturbation rejection. Preliminary
evaluation of the stability and robustness of the proposed approach is
demonstrated through the Gazebo simulation environment. In addition,
preliminary experimental results with (complete) paraplegic individuals are
included for the previous version of the controller.Comment: Submitted to IEEE Control System Magazine. This version addresses
reviewers' concerns about the robustness of the algorithm and the motivation
for using such exoskeleton
Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton
This paper presents design principles for comfort-centered wearable robots
and their application in a lightweight and backdrivable knee exoskeleton. The
mitigation of discomfort is treated as mechanical design and control issues and
three solutions are proposed in this paper: 1) a new wearable structure
optimizes the strap attachment configuration and suit layout to ameliorate
excessive shear forces of conventional wearable structure design; 2) rolling
knee joint and double-hinge mechanisms reduce the misalignment in the sagittal
and frontal plane, without increasing the mechanical complexity and inertia,
respectively; 3) a low impedance mechanical transmission reduces the reflected
inertia and damping of the actuator to human, thus the exoskeleton is
highly-backdrivable. Kinematic simulations demonstrate that misalignment
between the robot joint and knee joint can be reduced by 74% at maximum knee
flexion. In experiments, the exoskeleton in the unpowered mode exhibits 1.03 Nm
root mean square (RMS) low resistive torque. The torque control experiments
demonstrate 0.31 Nm RMS torque tracking error in three human subjects.Comment: 8 pages, 16figures, Journa
Simulation and design of an active orthosis for an incomplete spinal cord injured subject
The dynamic simulation of incomplete spinal cord injured individuals equipped with active orthoses is a challenging problem due to the redundancy of the simultaneous human-orthosis actuation. The objective of this work is two-fold. Firstly, a physiological static optimization approach to solve the muscle-orthosis actuation sharing problem is presented. For this purpose, a biomechanical model based on multibody dynamics techniques is used. The muscles are modeled as Hill-type actuators and the atrophy of denervated muscles is considered by adding stiff and dissipative elements. Secondly, the mechanical design of a new active stance-control knee-ankle-foot orthosis (A-SCKAFO) is addressed. The proposed device consists of a passive joint that constrains ankle plantar flexion, along with a powered knee unit that prevents flexion during stance and controls flexion-extension during swing. The knee actuation is selected based on the results obtained through the optimization approach.Peer ReviewedPostprint (published version
Energy efficiency analysis and design optimization of an actuation system in a soft modular lower limb exoskeleton
One of the critical aspects in the design of an assistive wearable robot is the energy efficiency of the actuation system, since it affects significantly the weight and consequently the comfort of the system. Several strategies have been used in previous research, mostly based on energy harvesting, compliant elements for mechanical energy accumulation (springs or elastic cords), ratchets and clutches. However, the design of the optimal actuator arrangement is highly dependent on the task, which increases significantly the complexity of the design process.
In this work we present an energy efficiency analysis and design optimization of an actuation system applied to a soft module lower limb exoskeleton. Instead of performing a comparison between predefined mechanism arrangements, we solve a full optimization problem which includes not only the mechanism parameters, but also the mechanism architecture itself. The optimization is performed for a walking task using gait data from a stroke subject, and the result is a set of actuator Arrangements with optimal parameters for the analyzed task and selected user. The optimized mechanism is able to reduce the energy requirements by 20-65%, depending of the joint. The proposed mechanism is currently under development within the XoSoft EU project, a modular soft lower-limb exoskeleton to assist People with mobility impairments
A flexible sensor technology for the distributed measurement of interaction pressure
We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted
Robotic Rehabilitation Devices of Human Extremities: Design Concepts and Functional Particularities
International audienceAll over the world, several dozen million people suffer from the effects of post-polio, multiple sclerosis, spinal cord injury, cerebral palsy, etc. and could benefit from the advances in robotic devices for rehabilitation. Thus, for modern society, an important and vital problem of designing systems for rehabilitation of human physical working ability appears. The temporary or permanent loss of human motor functions can be compensated by means of various rehabilitation devices. They can be simple mechanical systems for orthoses, which duplicate the functions of human extremities supplying with rigidity and bearing capacity or more complex mechatronic rehabilitation devices with higher level of control. We attempt to cover all of the major developments in these areas, focusing particularly on the development of the different concepts and their functional characteristics. The robotic devices with several structures are classified, taking into account the actuation systems, the neuromuscular stimulations, and the structural schemes. It is showed that the problems concerning the design of rehabilitation devices are complex and involve many questions in the sphere of biomedicine, mechanics, robot technology, electromechanics and optimal control. This paper provides a design overview of hardware, actuation, sensory, and control systems for most of the devices that have been described in the literature, and it ends with a discussion of the major advances that have been made and should be yet overcome
- …