9,312 research outputs found

    Design and Characterisation of an MRI Compatible Human Brain PET Insert by Means of Simulation and Experimental Studies

    Get PDF
    Positron emission tomography (PET) is a widely used in-vivo imaging technique to visualise metabolism, allowing for a broad spectrum of applications in oncology, cardiology and neuroscience. At present, an MRI compatible human brain PET scanner for applications in neuroscience is being constructed in the scope of a Helmholtz Validation Fund project. In this thesis, a detector for this novel PET device was designed. The detector concept combined three scintillator layers with a lightguide and digital silicon photomultipliers (dSiPMs). Monte Carlo simulations were used to optimise the dimensions of the scintillator arrays, so that the new scanner design yielded the maximum possible sensitivity. The benefit from the additional depth information, which can be acquired with three scintillator layers, was evaluated and proven to be higher compared to a less expensive two layer geometry. Since a more homogeneous spatial resolution was achieved in the whole field of view, this finding had a high relevance for the envisaged neuroscientific applications. In order to accurately acquire the depth information, new strategies for decoding the flood map during the calibration of a detector module were developed. This required realistic simulation data with ground truth information, so that the simulation toolkit GATE was extended to model the electronic readout of the dSiPMs. To overcome extended simulation times and to provide simulations on a statistically sound basis, the GATE studies were executed on the supercomputer JURECA. The simulated data were matched to measured data from test detectors. This allowed the determination of an optimum thickness of a lightguide between the scintillators and the dSiPMs. Moreover, the number of correctly identified scintillation events was evaluated by means of different event positioning approaches and different clustering methods during the calibration step. The highest amount of correctly identified events in a single detector block was achieved with model-based clustering and Maximum Likelihood positioning (61.5 %). By simulating the whole propagation and detection of scintillation photons including ground truth information, this study provides the opportunity to improve the positioning approaches and to enhance this number in future. The gained insights were further applied to select a surface finish of the scintillators. Measurements with crystal samples of the final detector dimensions showed that rough lateral crystal surfaces yielded the best signal separation in the calibration flood map. The experimental and simulation studies presented in this thesis had a major influence on the final detector design of the novel brain PET. The detailed simulations including the propagation and detection of scintillation photons were in good agreement with measured data, and could be a promising approach for future detector design studies

    GATE : a simulation toolkit for PET and SPECT

    Get PDF
    Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/

    Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices

    Get PDF
    A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.Comment: IEEE Transactions on Medical Imaging, 17 May 201

    Simulated design strategies for SPECT collimators to reduce the eddy currents induced by MRI gradient fields

    Get PDF
    Combining single photon emission computed tomography (SPECT) with magnetic resonance imaging (MRI) requires the insertion of highly conductive SPECT collimators inside the MRI scanner, resulting in an induced eddy current disturbing the combined system. We reduced the eddy currents due to the insert of a novel tungsten collimator inside transverse and longitudinal gradient coils. The collimator was produced with metal additive manufacturing, that is part of a microSPECT insert for a preclinical SPECT/MRI scanner. We characterized the induced magnetic field due to the gradient field and adapted the collimators to reduce the induced eddy currents. We modeled the x-, y-, and z-gradient coil and the different collimator designs and simulated them with FEKO, a three-dimensional method of moments / finite element methods (MoM/FEM) full-wave simulation tool. We used a time analysis approach to generate the pulsed magnetic field gradient. Simulation results show that the maximum induced field can be reduced by 50.82% in the final design bringing the maximum induced magnetic field to less than 2% of the applied gradient for all the gradient coils. The numerical model was validated with measurements and was proposed as a tool for studying the effect of a SPECT collimator within the MRI gradient coils

    Effects of dark counts on digital silicon photomultipliers performance

    Get PDF
    Digital Silicon Photomultipliers (dSiPM) are novel light detector that integrates single-photon avalanche photodiodes and CMOS logic into a single silicon chip and have been used for developing new, high performance detectors for Positron Emission Tomography (PET). As a solid-state devices they suffer from thermal excitation what leads to the appearance of noise events called dark counts. However, it is unclear what effect the dark counts have on the count rate performance of dSiPM. Therefore, it is necessary to investigate the event loss caused by these dark counts and to come up with optimal configuration of these devices. Here, the effects of dark counts on the performance of are evaluated. Due to the trigger architecture of dSiPM, dark counts cause start of acquisition sequence of the device. Processing of these dark counts leads to dead time of dSiPM what cause the loss of true gamma events. We studied how trigger level, validation level and validation length influence the loss of events due to dark counts. We found that validation time should be kept long (40 ns) to minimize the loss of events. Use of high trigger level and validation level also reduce the event loss caused by dark counts. However, with the high validation level, detection of events with low number of optical photons is reduced as it more difficult for these events to pass the validation threshold. The RTL refresh option was also tested to reduce the effect of dark counts. We found that this option resulted in the achieving maximum sensitivity, i.e. the highest fraction of correctly recorded true events, of dSiPM regardless of used validation and trigger levels. In cases when the scintillation light is spread over several dies, we found that the use of RTL refresh option combined with a low validation level in order to guarantee the individual validation of all required dies ensures higher sensitivity than the use of Neighbor Logic (NL). Finally we verified the dead time of dSiPM and found that is longer than specified and equal to 50 ns
    corecore