    Overview of Passive Light Emitting Diode Driver Circuits for Street Lighting

    Full text link
    This paper describes the overview and comparison of various passive Light Emitting Diode (LED) driver circuits employed for street lighting applications. Passive LED driver circuits are constructed with diodes and capacitors without using any power electronic semiconductor switches which in turn eliminates the secondary supply unit for control circuits and controllers. Passive LED driver circuits are simple in construction, low cost, less maintenance and control free. 50 W LED driver circuit is identified for performance comparison and simulations are performed in matlab- simulink to get an overview of different passive LED driver circuits. The most predominant parameters such as efficiency and total harmonic distortion are compared to identify the suitiblity of the driver circuits for various applications

    Overview of Passive Light Emitting Diode Driver Circuits for Street Lighting

    Get PDF
    This paper describes the overview and comparison of various passive Light Emitting Diode (LED) driver circuits employed for street lighting applications. Passive LED driver circuits are constructed with diodes and capacitors without using any power electronic semiconductor switches which in turn eliminates the secondary supply unit for control circuits and controllers. Passive LED driver circuits are simple in construction, low cost, less maintenance and control free. 50 W LED driver circuit is identified for performance comparison and simulations are performed in matlab- simulink to get an overview of different passive LED driver circuits. The most predominant parameters such as efficiency and total harmonic distortion are compared to identify the suitiblity of the driver circuits for various applications

    A review and classification of LED ballasts

    Get PDF
    This paper presents a review on existing ballasts for light-emitting diodes (LED) with considerations to their compliance to regulations, technological challenges, and on meeting various application requirements. All existing LED ballasts, including those proposed in recent literature, have been appropriately classified and systematically organized for the discussion. The dissemination of this information and its understanding is helpful for future R&D pursuits in this area. © 2013 IEEE.published_or_final_versio

    A Survey, Classification and Critical Review of Light-Emitting Diode Drivers

    Get PDF
    Based on a survey on over 1400 commercial LED drivers and a literature review, a range of LED driver topologies are classified according to their applications, power ratings, performance and their energy storage and regulatory requirements. Both passive and active LED drivers are included in the review and their advantages and disadvantages are discussed. This paper also presents an overall view on the technical and cost aspects of the LED technology, which is useful to both researchers and engineers in the lighting industry. Some general guidelines for selecting driver topologies are included to aid design engineers to make appropriate choices.published_or_final_versio

    A Single-phase Rectifier With Ripple-power Decoupling and Application to LED Lighting

    Get PDF
    In recent years, Light-Emitting-Diode (LED) is widely used in lighting applications for its high efficacy and high reliability. However, the rectifier, which is required by the LEDs to convert the AC power from the grid into DC power, suffers from low-reliability caused by the filtering capacitor. In order to fully utilize the long operational hours of the LEDs, this thesis proposes a rectifier that has improved reliability by adding a ripple-port to eliminate the non-reliable electrolytic capacitor. The ripple-port is capable of decoupling the ripple-power inherited in a single-phase rectifier, which enables using the reliable film capacitor to replace the electrolytic capacitor. To guarantee that the ripple-port can effectively decouple the ripple-power, a closed-loop control scheme is designed and implemented in a digital controller. Simulation and experimental results show that the proposed rectifier can reduce the required capacitance by 70%, which results in a 60% increase in lifetime. The proposed ripple-port circuit can be considered as an add-on module to be integrated into the rectifiers used in applications that require long lifetime. A detailed analysis of the efficiency, cost and reliability of applying the ripple-port in LED lighting applications supports the feasibility of the proposed circuit

    Integration of an Active Filter and a Single-Phase AC/DC Converter with Reduced Capacitance Requirement and Component Count

    Get PDF
    Existing methods of incorporating an active filter into an AC/DC converter for eliminating electrolytic capacitors usually require extra power switches. This inevitably leads to an increased system cost and degraded energy efficiency. In this paper, a concept of active-filter integration for single-phase AC/DC converters is reported. The resultant converters can provide simultaneous functions of power factor correction, DC voltage regulation, and active power decoupling for mitigating the low-frequency DC voltage ripple, without an electrolytic capacitor and extra power switch. To complement the operation, two closed-loop voltage-ripple-based reference generation methods are developed for controlling the energy storage components to achieve active power decoupling. Both simulation and experiment have confirmed the eligibility of the proposed concept and control methods in a 210-W rectification system comprising an H-bridge converter with a half-bridge active filter. Interestingly, the end converters (Type I and Type II) can be readily available using a conventional H-bridge converter with minor hardware modification. A stable DC output with merely 1.1% ripple is realized with two 50-μF film capacitors. For the same ripple performance, a 900-μF capacitor is required in conventional converters without an active filter. Moreover, it is found out that the active-filter integration concept might even improve the efficiency performance of the end converters as compared with the original AC/DC converter without integration

    Elimination of an Electrolytic Capacitor in AC/DC Light-Emitting Diode (LED) Driver With High Input Power Factor and Constant Output Current

    Get PDF
    published_or_final_versio

    Fault Tolerant DC–DC Converters at Homes and Offices

    Get PDF
    The emergence of direct current (DC) microgrids within the context of residential buildings and offices brings in a whole new paradigm in energy distribution. As a result, a set of technical challenges arise, concerning the adoption of efficient, cost-effective, and reliable DC-compatible power conditioning solutions, suitable to interface DC microgrids and energy consuming elements. This thesis encompasses the development of DC–DC power conversion solutions, featuring improved availability and efficiency, suitable to meet the requirements of a comprehensive set of end-uses commonly found in homes and offices. Based on the energy consumption profiles and requirements of the typical elements found at homes and offices, three distinctive groups are established: light-emitting diode (LED) lighting, electric vehicle (EV) charging, and general appliances. For each group, a careful evaluation of the criteria to fulfil is performed, based on which at least one DC–DC power converter is selected and investigated. Totally, a set of five DC–DC converter topologies are addressed in this work, being specific aspects related to fault diagnosis and/or fault tolerance analysed with particular detail in two of them. Firstly, mathematical models are described for LED devices and EV batteries, for the development of a theoretical analysis of the systems’ operation through computational simulations. Based on a compilation of requirements to account for in each end-use (LED lighting, EV charging, and general appliances), brief design considerations are drawn for each converter topology, regarding their architecture and control strategy. Aiming a detailed understanding of the two DC–DC power conversion systems subjected to thorough evaluation in this work – interleaved boost converter and fault-tolerant single-inductor multiple-output (SIMO) converter – under both normal and abnormal conditions, the operation of the systems is evaluated in the presence of open-circuit (OC) faults. Parameters of interest are monitored and evaluated to understand how the failures impact the operation of the entire system. At this stage, valuable information is obtained for the development of fault diagnosis strategies. Taking profit of the data collected in the analysis, a novel fault diagnostic strategy is presented, targeting interleaved DC–DC boost converters for general appliances. Ease of implementation, fast diagnostic and robustness against false alarms distinguish the proposed approach over the state-of-the-art. Its effectiveness is confirmed through a set of operation scenarios, implemented in both simulation environment and experimental context. Finally, an extensive set of reconfiguration strategies is presented and evaluated, aiming to grant fault tolerance capability to the multiple DC–DC converter topologies under analysis. A hybrid reconfiguration approach is developed for the interleaved boost converter. It is demonstrated that the combination of reconfiguration strategies promotes remarkable improvements on the post-fault operation of the converter. In addition, an alternative SIMO converter architecture, featuring inherent tolerance against OC faults, is presented and described. To exploit the OC fault tolerance capability of the fault-tolerant SIMO converter, a converter topology targeted at residential LED lighting systems, two alternative reconfiguration strategies are presented and evaluated in detail. Results obtained from computational simulations and experimental tests confirm the effectiveness of the approaches. To further improve the fault-tolerant SIMO converter with regards to its robustness against sensor faults, while simplifying its hardware architecture, a sensorless current control strategy is presented. The proposed control strategy is evaluated resorting to computational simulations.O surgimento de micro-redes em corrente contínua (CC) em edifícios residenciais e de escritórios estabelece um novo paradigma no domínio da distribuição de energia. Como consequência disso, surge uma panóplia de desafios técnicos ligados à adopção de soluções de conversão de energia, compatíveis com CC, que demonstrem ser eficientes, rentáveis e fiáveis, capazes de estabelecer a interface entre micro-redes em CC e as cargas alimentadas por esse sistema de energia. Até aos dias de hoje, os conversores CC–CC têm vindo a ser maioritariamente utilizados em aplicações de nicho, que geralmente envolvem níveis de potência reduzidos. Porém, as perspectivas futuras apontam para a adopção, em larga escala, destas tecnologias de conversão de energia, também em equipamentos eléctricos residenciais e de escritórios. Tal como qualquer outra tecnologia de conversão electrónica de potência, os conversores CC–CC podem ver o seu funcionamento afectado por falhas que degradam o seu bom funcionamento, sendo que essas falhas acabam por afectar não apenas os conversores em si, mas também as cargas que alimentam, limitando assim o tempo de vida útil do conjunto conversor + carga. Desta forma, é fulcral localizar a origem da falha, para que possam ser adoptadas acções correctivas, capazes de limitar as consequências nefastas associadas à falha. Para responder a este desafio, esta tese contempla o desenvolvimento de soluções de conversão de energia CC–CC altamente eficientes e fiáveis, capazes de responder a requisitos impostos por um conjunto alargado de equipamentos frequentemente encontrados em habitações e escritórios. Com base nos perfis de consumo de energia eléctrica e nos requisitos impostos pelas cargas tipicamente utilizadas em habitações e escritórios, são estabelecidos três grupos distintos: iluminação através de díodos emissores de luz, carregamento de veículo eléctrico (VE) e aparelhos eléctricos em geral. Para cada grupo, é efectuada uma avaliação cuidadosa dos critérios a respeitar, sendo com base nesses critérios que será escolhida e investigada pelo menos uma topologia de conversor CC–CC. No total, são abordadas cinco topologias de conversores CC–CC distintas, sendo que os aspectos ligados ao diagnóstico de avarias e/ou tolerância a falhas são analisados com particular detalhe em duas dessas topologias. Inicialmente, são estabelecidos modelos matemáticos descritivos do comportamento das principais cargas consideradas no estudo – díodos emissores de luz e baterias de VEs – visando a análise teórica do funcionamento dos sistemas em estudo, suportada por simulações computacionais. Com base numa compilação de requisitos a ter em conta em cada aplicação – iluminação através de díodos emissores de luz, carregamento de veículo eléctrico (VE) e aparelhos eléctricos em geral – são estabelecidas considerações ligadas à escolha de cada topologia de conversor não isolado, no que respeita à sua arquitectura e estratégia de controlo. Visando o conhecimento aprofundado das duas topologias de conversor CC–CC alvo de particular enfoque neste trabalho – conversor entrelaçado elevador e conversor de entrada única e múltiplas saídas, tolerante a falhas – quer em funcionamento normal, quer em funcionamento em modo de falha, é avaliado o funcionamento de ambas as topologias na presença de falhas de circuito aberto nos semicondutores activos. Para o efeito, são monitorizados e analisados parâmetros úteis à percepção da forma como os modos de falha avaliados neste trabalho impactam o funcionamento de todo o sistema. Nesta fase, é obtida informação fundamental ao desenvolvimento de estratégias de diagnóstico de avarias, particularmente indicadas para avarias de circuito aberto nos semicondutores activos dos conversores em estudo. Com base na informação recolhida anteriormente, é apresentada uma nova estratégia de diagnóstico de avarias direccionada a conversores CC–CC elevadores entrelaçados utilizados em aparelhos eléctricos, em geral. Facilidade de implementação, rapidez e robustez contra falsos positivos são algumas das características que distinguem a estratégia proposta em relação ao estado da arte. A sua efectividade é confirmada com recurso a uma multiplicidade de cenários de funcionamento, implementados quer em ambiente de simulação, quer em contexto experimental. Por fim, é apresentada e avaliada uma gama alargada de estratégias de reconfiguração, que visam assegurar a tolerância a falhas das diversas topologias de conversores CC–CC em estudo. É desenvolvida uma estratégia de reconfiguração híbrida, direccionada ao conversor entrelaçado elevador, que combina múltiplas medidas de reconfiguração mais simples num único procedimento. Demonstra-se que a combinação de múltiplas estratégias de reconfiguração introduz melhorias substanciais no funcionamento do conversor ao longo do período pós-falha, ao mesmo tempo que assegura a manutenção da qualidade da energia à entrada e saída do conversor reconfigurado. Noutra frente, é apresentada e descrita uma arquitectura alternativa do conversor de entrada única e múltiplas saídas, com tolerância a falhas de circuito aberto. Através da configuração proposta, é possível manter o fornecimento de energia eléctrica a todas as saídas do conversor. Para tirar máximo proveito da tolerância a falhas do conversor de entrada única e múltiplas saídas, uma topologia de conversor indicada para sistemas residenciais de iluminação baseados em díodos emissores de luz, são apresentadas e avaliadas duas estratégias de reconfiguração do conversor, exclusivamente baseadas na adaptação do controlo aplicado ao conversor. Os resultados de simulação computacional e os resultados experimentais obtidos confirmam a efectividade das abordagens adoptadas, através da melhoria da qualidade da energia eléctrica fornecida às diversas saídas do conversor. São assim asseguradas condições essenciais ao funcionamento ininterrupto e estável dos sistemas de iluminação, já que a qualidade da energia eléctrica fornecida aos sistemas de iluminação tem impacto directo na qualidade da luz produzida. Por fim, e para aprimorar o conversor de entrada única e múltiplas saídas tolerante a falhas, no que respeita à sua robustez contra falhas em sensores, é apresentada uma estratégia de controlo de corrente que evita o recurso excessivo a sensores e, ao mesmo tempo, simplifica a estrutura de controlo do conversor. A estratégia apresentada é avaliada através de simulações computacionais. A abordagem apresentada assume vantagens em múltiplos domínios, sendo de destacar vantagens como a melhoria da fiabilidade de todo o sistema de iluminação (conversor + carga), os ganhos atingidos ao nível do rendimento, a redução do custo de implementação da solução, ou a simplificação da estrutura de controlo.This work was supported by the Portuguese Foundation for Science and Technology (FCT) under grant number SFRH/BD/131002/2017, co-funded by the Ministry of Science, Technology and Higher Education (MCTES), by the European Social Fund (FSE) through the ‘Programa Operacional Regional Centro’ (POR-Centro), and by the Human Capital Operational Programme (POCH)

    Direct AC/DC rectifier with mitigated low-frequency ripple through waveform control

    Get PDF
    In a rectification system with unity power factor, the input power consists of a DC and a double-line frequency power component. Traditionally, an electrolytic capacitor (E-Cap) is used to buffer the double-line frequency power such that the DC output presents a small voltage ripple. The use of E-Cap significantly limits the lifetime of the rectifier system. In this paper, a differential AC/DC rectifier based on the use of an inductor-current waveform control methodology is proposed. The proposed configuration achieves single-stage direct AC/DC rectification without the needs of a front-stage diode rectifier circuit, an input EMI filter, and an E-Cap for buffering the double-line frequency power. The feasibility of the proposal has been practically confirmed in an experimental prototype. © IEEE.published_or_final_versio