914 research outputs found

    Wireless Power Transfer in Wearable Smart Contact Lenses [Open access]

    Get PDF
    In 2016, a smart contact lens was developed by Google company which aimed to directly implanting micro-smart lenses into the human eye to test blood sugar percentage by tears. However, small sizes implantable devices such as contact lens requires power transfer unit for continuously power supply. Thus, this project aims to design a power transfer unit with Inductively Coupled Power Transfer (ICPT) technology for smart contact lens which works under 2.45GHz to power an LED at load. The coil size is designed as 10mm inner diameter, 12mm outer diameter and 0.2mm wire width. Additionally, polydimethylsiloxane (PDMS) is used as the contact lens substrate. During the simulation, different eye models were built since the coil needs to be warped on top of lens and the eyeball, and under different conditions the S11 parameter is adjusted to around -10dB. The antenna is fabricated by technician in school, due to the technology restriction, the antenna was fabricated with unequal line width, which causes a resonate frequency shift to 900MHz with -8dB S11 value. To power an LED at load side, full-wave and half-wave rectifiers are built separately with different component values and send to fabrication. The antenna performance was tested under three conditions, in air, on human hand, and on water surface to imitate the liquid condition in human eye, but since the dielectric constant varies in each case, and for fabrication there is an extra circuit unit which effecting the copper coil numbers, the tested resonant frequency is not as desired values

    Wireless Power Transfer in Wearable Smart Contact Lenses [Open access]

    Get PDF
    In 2016, a smart contact lens was developed by Google company which aimed to directly implanting micro-smart lenses into the human eye to test blood sugar percentage by tears. However, small sizes implantable devices such as contact lens requires power transfer unit for continuously power supply. Thus, this project aims to design a power transfer unit with Inductively Coupled Power Transfer (ICPT) technology for smart contact lens which works under 2.45GHz to power an LED at load. The coil size is designed as 10mm inner diameter, 12mm outer diameter and 0.2mm wire width. Additionally, polydimethylsiloxane (PDMS) is used as the contact lens substrate. During the simulation, different eye models were built since the coil needs to be warped on top of lens and the eyeball, and under different conditions the S11 parameter is adjusted to around -10dB. The antenna is fabricated by technician in school, due to the technology restriction, the antenna was fabricated with unequal line width, which causes a resonate frequency shift to 900MHz with -8dB S11 value. To power an LED at load side, full-wave and half-wave rectifiers are built separately with different component values and send to fabrication. The antenna performance was tested under three conditions, in air, on human hand, and on water surface to imitate the liquid condition in human eye, but since the dielectric constant varies in each case, and for fabrication there is an extra circuit unit which effecting the copper coil numbers, the tested resonant frequency is not as desired values

    Design of Inductive Power Transfer (IPT) for Low-Power Application

    Get PDF
    Inductive power transfer (IPT) is preferred for numerous applications nowadays, ranging from microwatt bio-engineering devices to high power battery charging system. IPT system is based on the basic concept of electromagnetics induction which able to transfer the power from a source of electrical to the load without using any type of physical interconnection. This paper present a low-cost designed and implementation of IPT system via magnetic resonant coupling. NI Multisim 14.0 software was used to simulate the circuit diagram and the hardware prototype was developed for testing

    A Class-E Inductive Powering Link with Backward Data Communications for Implantable Sensor Systems

    Get PDF
    The design and implementation of a wireless power and data transfer system based on inductive coupling, having the potential to be used in numerous implantable bio-medical sensors and systems, is presented. The system consists of an external (primary) unit and an internal (secondary) unit. The external unit incorporates a high-efficiency switch-mode Class-E amplifier operating at ~200 kHz for driving the primary coil. The secondary unit consists of a parallel resonant coil followed by the power recovery circuitry. Means for backward data communication from the internal to the external unit over the same pair of coils has been realized using a simple FSK-based modulation scheme incorporated into the internal unit. FSK demodulation and associated filtering are integrated with the base inductive powering system. Prototype system test results indicate the inductive link efficiency can exceed 80% under optimum operating conditions with the overall power transfer efficiency of approximately 30%. The communication system is capable of transmitting up to 10kbps of data with the FSK carrier frequency (i.e., middle-frequency) being only 120kHz. The complete system functions reliably over an inter-coil distances exceeding 2.5cm with a 5V dc supply

    An efficient telemetry system for restoring sight

    Get PDF
    PhD ThesisThe human nervous system can be damaged as a result of disease or trauma, causing conditions such as Parkinson’s disease. Most people try pharmaceuticals as a primary method of treatment. However, drugs cannot restore some cases, such as visual disorder. Alternatively, this impairment can be treated with electronic neural prostheses. A retinal prosthesis is an example of that for restoring sight, but it is not efficient and only people with retinal pigmentosa benefit from it. In such treatments, stimulation of the nervous system can be achieved by electrical or optical means. In the latter case, the nerves need to be rendered light sensitive via genetic means (optogenetics). High radiance photonic devices are then required to deliver light to the target tissue. Such optical approaches hold the potential to be more effective while causing less harm to the brain tissue. As these devices are implanted in tissue, wireless means need to be used to communicate with them. For this, IEEE 802.15.6 or Bluetooth protocols at 2.4GHz are potentially compatible with most advanced electronic devices, and are also safe and secure. Also, wireless power delivery can operate the implanted device. In this thesis, a fully wireless and efficient visual cortical stimulator was designed to restore the sight of the blind. This system is likely to address 40% of the causes of blindness. In general, the system can be divided into two parts, hardware and software. Hardware parts include a wireless power transfer design, the communication device, power management, a processor and the control unit, and the 3D design for assembly. The software part contains the image simplification, image compression, data encoding, pulse modulation, and the control system. Real-time video streaming is processed and sent over Bluetooth, and data are received by the LPC4330 six layer implanted board. After retrieving the compressed data, the processed data are again sent to the implanted electrode/optrode to stimulate the brain’s nerve cells

    Advances in Microelectronics for Implantable Medical Devices

    Get PDF
    Implantable medical devices provide therapy to treat numerous health conditions as well as monitoring and diagnosis. Over the years, the development of these devices has seen remarkable progress thanks to tremendous advances in microelectronics, electrode technology, packaging and signal processing techniques. Many of today’s implantable devices use wireless technology to supply power and provide communication. There are many challenges when creating an implantable device. Issues such as reliable and fast bidirectional data communication, efficient power delivery to the implantable circuits, low noise and low power for the recording part of the system, and delivery of safe stimulation to avoid tissue and electrode damage are some of the challenges faced by the microelectronics circuit designer. This paper provides a review of advances in microelectronics over the last decade or so for implantable medical devices and systems. The focus is on neural recording and stimulation circuits suitable for fabrication in modern silicon process technologies and biotelemetry methods for power and data transfer, with particular emphasis on methods employing radio frequency inductive coupling. The paper concludes by highlighting some of the issues that will drive future research in the field

    Circuits and systems for inductive power transfer

    Get PDF
    Recently, the development of Wireless Power Transfer (WPT) systems has shown to be a key factor for improving the robustness, usability and autonomy of many mobile devices. The WPT link relaxes the trade-off between the battery size and the power availability, enabling highly innovative applications. This thesis aims to develop novel techniques to increase efficiency and operating distance of inductive power transfer systems. We addressed the design of the inductive link and various circuits used in the receiver. Moreover, we performed a careful system-level analysis, taking into account the design of different blocks and their interaction. The analysis is oriented towards the development of low power applications, such as Active Implantable Medical Device (AIMD) or Radio-Frequency Identification (RFID) systems. Three main approaches were considered to increase efficiency and operating distance: 1) The use of additional resonant coils, placed between the transmitter and the receiver. 2) The receiver coil impedance matching. 3) The design of high-efficiency rectifiers and dc-dc converters. The effect of the additional coils in the inductive link is usually studied without considering its influence on other parts of the WPT system. In this work, we theoretically analyzed and compared 2 and 3-coil links, showing the advantages of using the additional coil together with a matching network in the receiver. The effect of the additional coils in a closed-loop regulated system is also addressed, demonstrating that the feedback-loop design should consider the number of coils used in the link. Furthermore, the inclusion of one additional resonant coil in an actual half-duplex RFID system at 134:2 kHz is presented. The maximum efficiency point can be achieved by adjusting the receiver coil load impedance in order to reach its optimum value. In inductive powering, this optimum impedance is often achieved by adapting the input impedance of a dc-dc converter in the receiver. A matching network can also be used for the same purpose, as have been analyzed in previous works. In this thesis, we propose a joint design using both, matching network and dc-dc converters, highlighting the benefits of using the combined approach. A rectifier must be included in any WPT receiver. Usually, a dc-dc converter is included after the rectifier to adjust the output voltage or control the rectifier load impedance. The efficiency of both, rectifier and dc-dc converter, impacts not only the load power but also the receiver dissipation. In applications such as AIMDs, to get the most amount of power with low dissipation is crucial to full safety requirements. We present the design of an active rectifier and a switched capacitor dc-dc converter. In low-power applications, the power consumption of any auxiliary block used in the circuit may decrease the efficiency due to its quiescent consumption. Therefore, we have carefully designed these auxiliary blocks, such as operational transconductance amplifiers and voltage comparators. The main contributions of this thesis are: . Deduction of simplified equations to compare 2 and 3-coil links with an optimized Matching Network (MN). . Development of a 3-coil link half-duplex RFID 134.2 kHz system. . Analysis of the influence of the titanium case in the inductive link of implantable medical devices. . Development of a joint design ow which exploits the advantages of using both MNs and dc-dc converters in the receiver to achieve load impedance matching. . Analysis of closed-loop postregulated systems, highlighting the effects that the additional coils, receiver resonance (series or parallel), and type of driver (voltage or current) used in the transmitter, have in the feedback control loop. . Proposal of systematic analysis and design of charge recycling switches in step-up dc-dc converters. . New architecture for low-power high slew-rate operational transconductance amplifier. Novel architecture for high-efficiency active rectifier. The thesis is essentially based on the publications [1{9]. During the PhD program, other publications were generated [10{15] that are partially or non-included in the thesis. Additionally, some contributions presented in the text, are in process of publication.Hace ya un buen tiempo que las redes inalámbricas constituyen uno de los temas de investigación más estudiados en el área de las telecomunicaciones. Actualmente un gran porcentaje de los esfuerzos de la comunidad científifica y del sector industrial están concentrados en la definición de los requerimientos y estándares de la quinta generación de redes móviles. 5G implicará la integración y adaptación de varias tecnologías, no solo del campo de las telecomunicaciones sino también de la informática y del análisis de datos, con el objetivo de lograr una red lo suficientemente flexible y escalable como para satisfacer los requerimientos para la enorme variedad de casos de uso implicados en el desarrollo de la “sociedad conectada”. Un problema que se presenta en las redes inalámbricas actuales, que por lo tanto genera un desafío más que interesante para lo que se viene, es la escasez de espectro radioeléctrico para poder asignar bandas a nuevas tecnologías y nuevos servicios. El espectro está sobreasignado a los diferentes servicios de telecomunicaciones existentes y las bandas de uso libre o no licenciadas están cada vez más saturadas de equipos que trabajan en ellas (basta pensar lo que sucede en la banda no licenciada de 2.4 GHz). Sin embargo, existen análisis y mediciones que muestran que en diversas zonas y en diversas escalas de tiempo, el espectro radioeléctrico, si bien está formalmente asignado a algún servicio, no se utiliza plenamente existiendo tiempos durante los cuales ciertas bandas están libres y potencialmente podrían ser usadas. Esto ha llevado a que las Redes Radios Cognitivas, concepto que existe desde hace un tiempo, sean consideradas uno de los pilares para el desarrollo de las redes inalámbricas del futuro. En los ultimos años la transferencia inalámbrica de energía (WPT) ha cobrado especial atención, ya que logra aumentar la robustez, usabilidad y autonomía de los dispositivos móviles. Transferir energía inalámbricamente relaja el compromiso entre el tamaño de la batería y la disponibilidad de energía, permitiendo aplicaciones que de otro modo no serían posibles. Esta tesis tiene como objetivo desarrollar técnicas novedosas para aumentar la eficiencia y la distancia de transmisión de sistemas de transferencia inalámbrica por acople inductivo (IPT). Se abordó el diseño del enlace inductivo y varios circuitos utilizados en el receptor de energía. Además, realizamos un cuidadoso análisis a nivel sistema, teniendo en cuenta el diseño conjunto de diferentes bloques. Todo el trabajo está orientado hacia el desarrollo de aplicaciones de bajo consumo, como dispositivos médicos implantables activos (AIMD) o sistemas de identificación por radio frecuencia (RFID). Se consideraron principalmente tres enfoques para lograr mayor eficienciay distancia: 1) El uso de bobinas resonantes adicionales, colocadas entre el transmisor y el receptor. 2) El uso de redes de adaptación de impedancia en el receptor. 3) El diseño de circuitos rectificdores y conversores dc-dc con alta eficiencia.El efecto ocasionado por las bobinas resonantes adicionales en el enlace inductivo es usualmente abordado sin tener en cuenta su influenciaen todas las partes del sistema. En este trabajo, analizamos teóricamente y comparamos sistemas de 2 y 3 bobinas, mostrando las ventajas que tiene la bobina adicional en conjunto con el uso de redes de adaptación. El efecto de dicha bobina, en sistemas de lazo cerrado fue también estudiado, demostrando que el diseño del lazo debe considerar el número de bobinas que utiliza el link. Se trabajó con un sistema real de RFID, analizando el uso de una bobina resonante en una aplicación práctica existente y de amplio uso en el Uruguay

    Design criteria of a transcutaneous power delivery system for implantable devices.

    Get PDF
    Implantable cardiac assist devices such as artificial hearts and blood pumps are a rapidly growing therapy used for treating moderate to severe congestive heart failure. While current treatments offer improved heart failure survival and increased patient functionality with enhanced quality of life, powering these devices are still constraining. In practice, percutaneous cables passing through skin are used for power and control data transmission requiring patients to maintain a sterile dressing on the skin cable-exit site. This contact site limits patient movement as it is vulnerable to wound infection due to trauma and poor healing. As a result, a sterile dressing has to be maintained and nursed regularly for treating the wound. Complications from the exit site infections are a leading cause of death in long-term support with these devices. Wireless power and control transmission systems have been studied and developed over years in order to avoid percutaneous cables while supplying power efficiently to the implanted device. These power systems, commonly named Transcutaneous Energy Transfer (TET) systems, enable power transmission across the skin without direct electrical connectivity to the power source. TET systems use time-varying electromagnetic induction produced by a primary coil that is usually placed near skin outside the body. The induced voltage in an implanted secondary coil is then rectified and regulated to transfer energy to an implanted rechargeable battery in order to power the biomedical load device. Efficient and optimum energy transfer using such transcutaneous methods is more complex for mobile patients due to coupling discrepancies caused by variations in the alignment of the coil. The research studies equivalent maximum power transfer topologies for evaluating voltage gain and coupling link efficiency of TET system. Also, this research adds to previous efforts by generalizing different scenarios of misalignments of different coil size that affects the coupling link. As a whole, this study of geometric coil misalignments reconsiders potential anatomic location for coil placement to optimize TET systems performance in anticipated environment for efficient and safe operation.--Abstract

    Doctor of Philosophy

    Get PDF
    dissertationSince the late 1950s, scientists have been working toward realizing implantable devices that would directly monitor or even control the human body's internal activities. Sophisticated microsystems are used to improve our understanding of internal biological processes in animals and humans. The diversity of biomedical research dictates that microsystems must be developed and customized specifically for each new application. For advanced long-term experiments, a custom designed system-on-chip (SoC) is usually necessary to meet desired specifications. Custom SoCs, however, are often prohibitively expensive, preventing many new ideas from being explored. In this work, we have identified a set of sensors that are frequently used in biomedical research and developed a single-chip integrated microsystem that offers the most commonly used sensor interfaces, high computational power, and which requires minimum external components to operate. Included peripherals can also drive chemical reactions by setting the appropriate voltages or currents across electrodes. The SoC is highly modular and well suited for prototyping in and ex vivo experimental devices. The system runs from a primary or secondary battery that can be recharged via two inductively coupled coils. The SoC includes a 16-bit microprocessor with 32 kB of on chip SRAM. The digital core consumes 350 μW at 10 MHz and is capable of running at frequencies up to 200 MHz. The integrated microsystem has been fabricated in a 65 nm CMOS technology and the silicon has been fully tested. Integrated peripherals include two sigma-delta analog-to-digital converters, two 10-bit digital-to-analog converters, and a sleep mode timer. The system also includes a wireless ultra-wideband (UWB) transmitter. The fullydigital transmitter implementation occupies 68 x 68 μm2 of silicon area, consumes 0.72 μW static power, and achieves an energy efficiency of 19 pJ/pulse at 200 MHz pulse repetition frequency. An investigation of the suitability of the UWB technology for neural recording systems is also presented. Experimental data capturing the UWB signal transmission through an animal head are presented and a statistical model for large-scale signal fading is developed
    corecore