64 research outputs found

    Optimized Screening of Glaucoma using Fundus Images and Deep Learning

    Get PDF
    Diabetic retinopathy, glaucoma, and age-related macular degeneration are among the leading causes of global visual loss. Early detection and diagnosis of these conditions are crucial to reduce vision loss and improve patient outcomes. In recent years, deep learning algorithms have shown great potential in automating the diagnosis and categorization of eye disorders using medical photos. For this purpose, the ResNet-50 architecture is employed in a deep learning-based strategy. The approach involves fine-tuning a pre-trained ResNet-50 model using over 5,000 retinal pictures from the ODIR dataset, covering ten different ocular diseases. To enhance the model's generalization performance and avoid overfitting, various data augmentation techniques are applied to the training data. The model successfully detects glaucoma-related ocular illnesses, including cataract, diabetic retinopathy, and healthy eyes. Performance evaluation using metrics like accuracy, precision, recall, and F1-score shows that the model achieved 92.60% accuracy, 93.54% precision, 91.60% recall, and an F1-score of 91.68%. These results indicate that the proposed strategy outperforms many state-of-the-art approaches in the detection and categorization of eye disorders. This success underscores the potential of deep learning-based methods in automated ocular illness identification, facilitating early diagnosis and timely treatment to ultimately improve patient outcomes

    Machine Learning for Glaucoma Assessment using Fundus Images

    Full text link
    [ES] Las imágenes de fondo de ojo son muy utilizadas por los oftalmólogos para la evaluación de la retina y la detección de glaucoma. Esta patología es la segunda causa de ceguera en el mundo, según estudios de la Organización Mundial de la Salud (OMS). En esta tesis doctoral, se estudian algoritmos de aprendizaje automático (machine learning) para la evaluación automática del glaucoma usando imágenes de fondo de ojo. En primer lugar, se proponen dos métodos para la segmentación automática. El primer método utiliza la transformación Watershed Estocástica para segmentar la copa óptica y posteriormente medir características clínicas como la relación Copa/Disco y la regla ISNT. El segundo método es una arquitectura U-Net que se usa específicamente para la segmentación del disco óptico y la copa óptica. A continuación, se presentan sistemas automáticos de evaluación del glaucoma basados en redes neuronales convolucionales (CNN por sus siglas en inglés). En este enfoque se utilizan diferentes modelos entrenados en ImageNet como clasificadores automáticos de glaucoma, usando fine-tuning. Esta nueva técnica permite detectar el glaucoma sin segmentación previa o extracción de características. Además, este enfoque presenta una mejora considerable del rendimiento comparado con otros trabajos del estado del arte. En tercer lugar, dada la dificultad de obtener grandes cantidades de imágenes etiquetadas (glaucoma/no glaucoma), esta tesis también aborda el problema de la síntesis de imágenes de la retina. En concreto se analizaron dos arquitecturas diferentes para la síntesis de imágenes, las arquitecturas Variational Autoencoder (VAE) y la Generative Adversarial Networks (GAN). Con estas arquitecturas se generaron imágenes sintéticas que se analizaron cualitativa y cuantitativamente, obteniendo un rendimiento similar a otros trabajos en la literatura. Finalmente, en esta tesis se plantea la utilización de un tipo de GAN (DCGAN) como alternativa a los sistemas automáticos de evaluación del glaucoma presentados anteriormente. Para alcanzar este objetivo se implementó un algoritmo de aprendizaje semi-supervisado.[CA] Les imatges de fons d'ull són molt utilitzades pels oftalmòlegs per a l'avaluació de la retina i la detecció de glaucoma. Aquesta patologia és la segona causa de ceguesa al món, segons estudis de l'Organització Mundial de la Salut (OMS). En aquesta tesi doctoral, s'estudien algoritmes d'aprenentatge automàtic (machine learning) per a l'avaluació automàtica del glaucoma usant imatges de fons d'ull. En primer lloc, es proposen dos mètodes per a la segmentació automàtica. El primer mètode utilitza la transformació Watershed Estocàstica per segmentar la copa òptica i després mesurar característiques clíniques com la relació Copa / Disc i la regla ISNT. El segon mètode és una arquitectura U-Net que s'usa específicament per a la segmentació del disc òptic i la copa òptica. A continuació, es presenten sistemes automàtics d'avaluació del glaucoma basats en xarxes neuronals convolucionals (CNN per les sigles en anglès). En aquest enfocament s'utilitzen diferents models entrenats en ImageNet com classificadors automàtics de glaucoma, usant fine-tuning. Aquesta nova tècnica permet detectar el glaucoma sense segmentació prèvia o extracció de característiques. A més, aquest enfocament presenta una millora considerable del rendiment comparat amb altres treballs de l'estat de l'art. En tercer lloc, donada la dificultat d'obtenir grans quantitats d'imatges etiquetades (glaucoma / no glaucoma), aquesta tesi també aborda el problema de la síntesi d'imatges de la retina. En concret es van analitzar dues arquitectures diferents per a la síntesi d'imatges, les arquitectures Variational Autoencoder (VAE) i la Generative adversarial Networks (GAN). Amb aquestes arquitectures es van generar imatges sintètiques que es van analitzar qualitativament i quantitativament, obtenint un rendiment similar a altres treballs a la literatura. Finalment, en aquesta tesi es planteja la utilització d'un tipus de GAN (DCGAN) com a alternativa als sistemes automàtics d'avaluació del glaucoma presentats anteriorment. Per assolir aquest objectiu es va implementar un algoritme d'aprenentatge semi-supervisat.[EN] Fundus images are widely used by ophthalmologists to assess the retina and detect glaucoma, which is, according to studies from the World Health Organization (WHO), the second cause of blindness worldwide. In this thesis, machine learning algorithms for automatic glaucoma assessment using fundus images are studied. First, two methods for automatic segmentation are proposed. The first method uses the Stochastic Watershed transformation to segment the optic cup and measures clinical features such as the Cup/Disc ratio and ISNT rule. The second method is a U-Net architecture focused on the optic disc and optic cup segmentation task. Secondly, automated glaucoma assessment systems using convolutional neural networks (CNNs) are presented. In this approach, different ImageNet-trained models are fine-tuned and used as automatic glaucoma classifiers. These new techniques allow detecting glaucoma without previous segmentation or feature extraction. Moreover, it improves the performance of other state-of-art works. Thirdly, given the difficulty of getting large amounts of glaucoma-labelled images, this thesis addresses the problem of retinal image synthesis. Two different architectures for image synthesis, the Variational Autoencoder (VAE) and Generative Adversarial Networks (GAN) architectures, were analysed. Using these models, synthetic images that were qualitative and quantitative analysed, reporting state-of-the-art performance, were generated. Finally, an adversarial model is used to create an alternative automatic glaucoma assessment system. In this part, a semi-supervised learning algorithm was implemented to reach this goal.The research derived from this doctoral thesis has been supported by the Generalitat Valenciana under the scholarship Santiago Grisolía [GRISOLIA/2015/027].Díaz Pinto, AY. (2019). Machine Learning for Glaucoma Assessment using Fundus Images [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/124351TESI

    A retinal vasculature tracking system guided by a deep architecture

    Get PDF
    Many diseases such as diabetic retinopathy (DR) and cardiovascular diseases show their early signs on retinal vasculature. Analysing the vasculature in fundus images may provide a tool for ophthalmologists to diagnose eye-related diseases and to monitor their progression. These analyses may also facilitate the discovery of new relations between changes on retinal vasculature and the existence or progression of related diseases or to validate present relations. In this thesis, a data driven method, namely a Translational Deep Belief Net (a TDBN), is adapted to vasculature segmentation. The segmentation performance of the TDBN on low resolution images was found to be comparable to that of the best-performing methods. Later, this network is used for the implementation of super-resolution for the segmentation of high resolution images. This approach provided an acceleration during segmentation, which relates to down-sampling ratio of an input fundus image. Finally, the TDBN is extended for the generation of probability maps for the existence of vessel parts, namely vessel interior, centreline, boundary and crossing/bifurcation patterns in centrelines. These probability maps are used to guide a probabilistic vasculature tracking system. Although segmentation can provide vasculature existence in a fundus image, it does not give quantifiable measures for vasculature. The latter has more practical value in medical clinics. In the second half of the thesis, a retinal vasculature tracking system is presented. This system uses Particle Filters to describe vessel morphology and topology. Apart from previous studies, the guidance for tracking is provided with the combination of probability maps generated by the TDBN. The experiments on a publicly available dataset, REVIEW, showed that the consistency of vessel widths predicted by the proposed method was better than that obtained from observers. Moreover, very noisy and low contrast vessel boundaries, which were hardly identifiable to the naked eye, were accurately estimated by the proposed tracking system. Also, bifurcation/crossing locations during the course of tracking were detected almost completely. Considering these promising initial results, future work involves analysing the performance of the tracking system on automatic detection of complete vessel networks in fundus images.Open Acces
    corecore