6,931 research outputs found

    Patient-Specific Method of Generating Parametric Maps of Patlak K(i) without Blood Sampling or Metabolite Correction: A Feasibility Study.

    Get PDF
    Currently, kinetic analyses using dynamic positron emission tomography (PET) experience very limited use despite their potential for improving quantitative accuracy in several clinical and research applications. For targeted volume applications, such as radiation treatment planning, treatment monitoring, and cerebral metabolic studies, the key to implementation of these methods is the determination of an arterial input function, which can include time-consuming analysis of blood samples for metabolite correction. Targeted kinetic applications would become practical for the clinic if blood sampling and metabolite correction could be avoided. To this end, we developed a novel method (Patlak-P) of generating parametric maps that is identical to Patlak K(i) (within a global scalar multiple) but does not require the determination of the arterial input function or metabolite correction. In this initial study, we show that Patlak-P (a) mimics Patlak K(i) images in terms of visual assessment and target-to-background (TB) ratios of regions of elevated uptake, (b) has higher visual contrast and (generally) better image quality than SUV, and (c) may have an important role in improving radiotherapy planning, therapy monitoring, and neurometabolism studies

    Spatial two tissue compartment model for DCE-MRI

    Full text link
    In the quantitative analysis of Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) compartment models allow to describe the uptake of contrast medium with biological meaningful kinetic parameters. As simple models often fail to adequately describe the observed uptake behavior, more complex compartment models have been proposed. However, the nonlinear regression problem arising from more complex compartment models often suffers from parameter redundancy. In this paper, we incorporate spatial smoothness on the kinetic parameters of a two tissue compartment model by imposing Gaussian Markov random field priors on them. We analyse to what extent this spatial regularisation helps to avoid parameter redundancy and to obtain stable parameter estimates. Choosing a full Bayesian approach, we obtain posteriors and point estimates running Markov Chain Monte Carlo simulations. The proposed approach is evaluated for simulated concentration time curves as well as for in vivo data from a breast cancer study

    Improvements In computed tomography perfusion output using complex singular value decomposition and the maximum slope algorithm

    Full text link
    OBJECTIVE: Determine if complex singular value decomposition (cSVD) used as preprocessing in the maximum slope algorithm reduces image noise of resultant physiologic parametric images. Noise will be decreased in the parametric maps of cerebral blood flow (CBF), cerebral blood volume (CBV) as compared to the same algorithm and data set with no cSVD applied. MATERIALS AND METHODS: A set of 10 patients (n=15) underwent a total combined 15 CT perfusion studies upon presenting with stroke symptoms. It was determined these patients suffered from occlusions resulting in a prolonged arrival time of blood to the brain. DICOM data files of these patients scans were selected based on this increased arrival delay. We compared the output of estimation calculations for cerebral blood flow (CBF), and cerebral blood volume (CBV), using preprocessing cSVD against the same scan data with no preprocessing cSVD. Image noise was assessed through the calculation of the standard deviation within specific regions of interest copied to specific areas of grey and white matter as well as CSF space. A decrease in the standard deviation values will indicate improvement in the noise level of the resultant images.. Results for the mean value within the regions of interest are expected to be similar between the groups calculated using cSVD and those calculated under the standard method. This will indicate the presence of minimal bias. RESULTS: Between groups of the standard processing method and the cSVD method standard deviation (SD) reductions were seen in both CBF and CBV values across all three ROIs. In grey matter measures of CBV, SD was reduced an average of 0.0034 mL/100g while measures of CBF saw SD reduced by an average of 0.073 mL/100g/min. In samples of white matter, standard deviations of CBV values were reduced on average by 0.0041mL/100g while CBF SD's were reduced by 0.073 mL/100g/min. CSF ROIs in CBV calculations saw SD reductions averaging 0.0047 mL/100g and reductions of 0.074 mL/100g/min in measures of CBF. Bias within CBV calculations was at most minimal as determined by no significant changes in mean calculated values. Calculations of CBF saw large downward bias in the mean values. CONCLUSIONS: The application of the cSVD method to preprocessing of CT perfusion imaging studies produces an effective method of noise reduction. In calculations of CBV, cSVD noise reduction results in overall improvement. In calculations of CBF, cSVD, while effective in noise reduction, caused mean values to be statistically lower than the standard method. It should be noted that there is currently no evaluation of which values can be considered more accurate physiologically. Simulations of the effect of noise on CBF showed a positive correlation suggesting that the CBF algorithm itself is sensitive to the level of noise

    Robust evaluation of contrast-enhanced imaging for perfusion quantification

    Get PDF

    Information technology applications in biomedical functional imaging

    Get PDF
    Author name used in this publication: (David) Dagan FengCentre for Multimedia Signal Processing, Department of Electronic and Information EngineeringVersion of RecordPublishe

    Mathematics and Medicine: How mathematics, modelling and simulations can lead to better diagnosis and treatments

    Get PDF
    Starting with the discovery of X-rays by Röntgen in 1895, the progress in medical imaging has been extraordinary and immensely beneficial to diagnosis and therapy. Parallel to the increase of imaging accuracy, there is the quest of moving from qualitative to quantitative analysis and patient-tailored therapy. Mathematics, modelling and simulations are increasing their importance as tools in this quest. In this paper we give an overview of relations between mathematical modelling and imaging and focus particularly on the estimation of perfusion in the brain. In the forward model, the brain is treated as a porous medium and a two compartment model (arterial/venous) is used. Motivated by the similarity with techniques in reservoir modelling, we propose an ensemble Kalman filter to perform the parameter estimation and apply the method to a simple example as an illustrative example.acceptedVersio

    Spatio-Temporal Modelling of Perfusion Cardiovascular MRI

    Get PDF
    Myocardial perfusion MRI provides valuable insight into how coronary artery and microvascular diseases affect myocardial tissue. Stenosis in a coronary vessel leads to reduced maximum blood flow (MBF), but collaterals may secure the blood supply of the myocardium but with altered tracer kinetics. To date, quantitative analysis of myocardial perfusion MRI has only been performed on a local level, largely ignoring the contextual information inherent in different myocardial segments. This paper proposes to quantify the spatial dependencies between the local kinetics via a Hierarchical Bayesian Model (HBM). In the proposed framework, all local systems are modelled simultaneously along with their dependencies, thus allowing more robust context-driven estimation of local kinetics. Detailed validation on both simulated and patient data is provided
    corecore