    Assessing the perceived quality of brachial artery Flow Mediated Dilation studies for inclusion in meta-analyses and systematic reviews: Description of data employed in the development of a scoring tool based on currently accepted guidelines

    Get PDF
    Brachial artery Flow Mediated Dilation (FMD) is widely used as a non-invasive measure of endothelial function. Adherence to expert consensus guidelines on FMD measurement has been found to be of vital importance to obtain reproducible data. This article lists the literature data which was considered in the development of a tool to aid in the objective judgement of the extent to which published studies adhered to expert guidelines for FMD measurement. Application of this tool in a systematic review of FMD studies © 2016 . (http://dx.doi.org/10.1016/j.atherosclerosis.2016.03.011) (Greyling et al., 2016 [1]) indicated that adherence to expert consensus guidelines is strongly correlated to the reproducibility of FMD data

    Adipocytokine levels mark endothelial function in normotensive individuals

    Get PDF
    BACKGROUND: Endothelial dysfunction is an independent risk factor for cardiovascular events. Inflammatory mediators released by the adipose tissue can lead to local insulin resistance and endothelial dysfunction. This study addressed the relationship of adipocytokines with endothelial function and blood pressure. METHODS: In 92 newly diagnosed, drug-naïve essential hypertensive patients (HT, mean age 49 yrs) without organ damage and 66 normotensive subjects (NT, mean age 47 yrs), by an automated system, we measured endothelium-dependent and -independent vasodilation as brachial artery flow-mediated dilation before and after administration of glyceryl-trinitrate. Retinol binding protein-4 (RBP4) and resistin levels were determined by ELISA and RIA, respectively. Oxidative stress was evaluated by measuring serum malondyaldehyde (MDA). RESULTS: Flow-mediated dilation was significantly (p = 0.03) lower in HT (5.3 ± 2.6%) than NT (6.1 ± 3.1%), while response to glyceryl-trinitrate (7.5 ± 3.7% vs 7.9 ± 3.4%) was similar. RBP4 (60.6 ± 25.1 vs 61.3 ± 25.9 μg/ml), resistin (18.8 ± 5.3 vs 19.9 ± 6.1 ng/ml) and MDA levels (2.39 ± 1.26 vs 2.08 ± 1.17 nmol/ml) were not different in HT and NT. RBP4 (r = −0.25; p = 0.04) and resistin levels (r = −0.29; p = 0.03) were related to flow-mediated dilation in NT, but not in HT (r = −0.03 and r = −0.10, respectively). In NT, multivariate analysis including RBP4 and confounders showed that only BMI or waist circumference remained related to flow- mediated dilation. In the multivariate model including resistin and confounders, BMI, age and resistin were significantly related to flow-mediated dilation, while only age significant correlated with this parameter when BMI was replaced by waist circumference. CONCLUSIONS: Adipocytokine levels may be independent predictors of endothelial dysfunction in the peripheral circulation of healthy subjects, providing a pathophysiological link between inflammation from adipose tissue and early vascular alterations

    Endothelial and Metabolic Function Interactions in Overweight/Obese Children.

    Get PDF
    AIM: Although the underlined mechanisms are still unknown, metabolic/coagulation alterations related to childhood obesity can induce vascular impairments. The aim of this study was to investigate the relationship between metabolic/coagulation parameters and endothelial function/vascular morphology in overweight/obese children. METHODS: Thirty-five obese/overweight children (22 pre-pubertal, mean age: 9.52±3.35 years) were enrolled. Body mass index (BMI), homeostasis model assessment index (HOMAIR), metabolic and coagulation parameters, [adiponectin, fibrinogen, high molecular weight adiponectin (HMW), endothelin-1, and vonWillebrand factor antigen] ultrasound early markers of atherosclerosis [flow-mediated dilatation (FMD), common carotid intima-media thickness (C-IMT), and anteroposterior diameter of infra-renal abdominal aorta (APAO)] were assessed. RESULTS: APAO was related to anthropometric (age: r=0.520, p=0.001; height: r=0.679, p<0.001; weight: r=0.548, p=0.001; BMI: r=0.607, p<0.001; SBP: r=0.377, p=0.026) and metabolic (HOMAIR: r=0.357, p=0.035; HMW: r=-0.355, p=0.036) parameters. Age, height, and systolic blood pressure were positively related to increased C-IMT (r=0.352, p=0.038; r=0.356, p=0.036; r=0.346, p=0.042, respectively). FMD was not related to any clinical and biochemical characteristics of the pediatric population. Age, HOMAIR, fasting glucose levels, and HMW were independent predictors for APAO increase. Each unit decrease in HMW concentrations (1 μg/ml) induced a 0.065 mm increase in APAO. CONCLUSION: High molecular weight adiponectin is related to cardiovascular risk in overweight/obese children

    Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods

    Get PDF
    Automated and high performance carotid intima-media thickness (IMT) measurement is gaining increasing importance in clinical practice to assess the cardiovascular risk of patients. In this paper, we compare four fully automated IMT measurement techniques (CALEX, CAMES, CARES and CAUDLES) and one semi-automated technique (FOAM). We present our experience using these algorithms, whose lumen-intima and media-adventitia border estimation use different methods that can be: (a) edge-based; (b) training-based; (c) feature-based; or (d) directional Edge-Flow based. Our database (DB) consisted of 665 images that represented a multi-ethnic group and was acquired using four OEM scanners. The performance evaluation protocol adopted error measures, reproducibility measures, and Figure of Merit (FoM). FOAM showed the best performance, with an IMT bias equal to 0.025 ± 0.225 mm, and a FoM equal to 96.6%. Among the four automated methods, CARES showed the best results with a bias of 0.032 ± 0.279 mm, and a FoM to 95.6%, which was statistically comparable to that of FOAM performance in terms of accuracy and reproducibility. This is the first time that completely automated and user-driven techniques have been compared on a multi-ethnic dataset, acquired using multiple original equipment manufacturer (OEM) machines with different gain settings, representing normal and pathologic case

    Model-Based Analysis of Flow-Mediated Dilation and Intima-Media Thickness

    Get PDF
    We present an end-to-end system for the automatic measurement of flow-mediated dilation (FMD) and intima-media thickness (IMT) for the assessment of the arterial function. The video sequences are acquired from a B-mode echographic scanner. A spline model (deformable template) is fitted to the data to detect the artery boundaries and track them all along the video sequence. The a priori knowledge about the image features and its content is exploited. Preprocessing is performed to improve both the visual quality of video frames for visual inspection and the performance of the segmentation algorithm without affecting the accuracy of the measurements. The system allows real-time processing as well as a high level of interactivity with the user. This is obtained by a graphical user interface (GUI) enabling the cardiologist to supervise the whole process and to eventually reset the contour extraction at any point in time. The system was validated and the accuracy, reproducibility, and repeatability of the measurements were assessed with extensive in vivo experiments. Jointly with the user friendliness, low cost, and robustness, this makes the system suitable for both research and daily clinical use

    Endothelial Dysfunction, Molecular Biology, Physiopathology, Diagnosis, and Treatment

    Get PDF
    Endothelial cell dysfunction has lately become one of the principal subjects being incorporated into the assessment of cardiovascular risk because of the relevance that has been shown in several clinical studies. Comprehending and incorporating basic physiological knowledge, about endothelium molecular biology and vascular tonicity, is key to understanding the relevance of this topic. The approach of endothelial dysfunction physiopathology is overly complex and widely studied, but it can be enrolled into both consumption of bioavailable NO and deficit production of NO. In the last decades, scientific equipment has been developed from the necessity of creating non-invasive tools to measure arterial stiffness, being FMD one of the first and most used ones. Once the endothelial cell dysfunction was identified, several drugs and bioactive substances were evaluated because of their potential to decrease the level of arterial stiffness and improve life quality, such as polyphenols, phosphodiesterase five inhibitors, and new incoming therapies

    Positive effects of tomato paste on vascular function after a fat meal in male healthy subjects

    Get PDF
    Tomato consumption has been recently associated with a reduced incidence of cardiovascular disease (CVD). The aim of this study was to test whether a seven-day period of tomato paste pur\ue8e (tomato paste, TP) supplementation could improve some haemodynamic parameters in healthy volunteers before and after a standardized fat meal (FM)

    Automated quantification and classification of human kidney microstructures obtained by optical coherence tomography

    Get PDF
    Optical coherence tomography (OCT) is a rapidly emerging imaging modality that can non-invasively provide cross-sectional, high-resolution images of tissue morphology such as kidney in situ and in real-time. Because the viability of a donor kidney is closely correlated with its tubular morphology, and a large amount of image datasets are expected when using OCT to scan the entire kidney, it is necessary to develop automated image analysis methods to quantify the spatially-resolved morphometric parameters such as tubular diameter, and to classify various microstructures. In this study, we imaged the human kidney in vitro, quantified the diameters of hollow structures such as blood vessels and uriniferous tubules, and classified those structures automatically. The quantification accuracy was validated. This work can enable studies to determine the clinical utility of OCT for kidney imaging, as well as studies to evaluate kidney morphology as a biomarker for assessing kidney's viability prior to transplantation