7 research outputs found

    Optimal linear quadratic Gaussian control based frequency regulation with communication delays in power system

    Get PDF
    In this paper, load frequency regulator based on linear quadratic Gaussian (LQG) is designed for the MAPS with communication delays. The communication delay is considered to denote the small time delay in a local control area of a wide-area power system. The system is modeled in the state space with inclusion of the delay state matrix parameters. Since some state variables are difficult to measure in a real modern multi-area power system, Kalman filter is used to estimate the unmeasured variables. In addition, the controller with the optimal feedback gain reduces the frequency spikes to zero and keeps the system stable. Lyapunov function based on the LMI technique is used to re-assure the asymptotically stability and the convergence of the estimator error. The designed LQG is simulated in a two area connected power network with considerable time delay. The result from the simulations indicates that the controller performed with expectation in terms of damping the frequency fluctuations and area control errors. It also solved the limitation of other controllers which need to measure all the system state variables

    Extended state observer based load frequency controller for three area interconnected power system

    Get PDF
    In this paper, we develop a new extended state variable observer based LFC scheme for three-area interconnected power systems. The extended state observerbased load frequency controllers are developed which utilize disturbance estimation techniques. The propose control approach assures that the fluctuating things of the load frequencies reaches to a safer range and the load frequencies can also be made at a very minimal not to have an effect on power quality and power flow in multi-area interconnected power system. The results of the simulations using MATLAB/SIMULINK done did not only address that the proposed newly control method works effectively but also change powerfully the parameter variations of the interconnected areas of the power system. Especially, it works very well to limit disturbances impact on interconnected areas in the system. Therefore, the performance of interconnected power system under different multi-conditions is simulated with the new control method to demonstrate the feasibility of the system

    Prediction-Based Super Twisting Sliding Mode Load Frequency Control for Multi Area Interconnected Power Systems with State and Input Time Delays using Disturbance Observer

    Get PDF
    International audienceA shift in paradigm from dedicated to open communication channels in power systems have made them prone to constant and time varying delays. This paper tackles a novel load frequency control (LFC) problem in the presence of constant and time varying delays in state and control input under load disturbances. The presence of time delays can deteriorate the performance of the controller or even destabilize the system. The above problem is addressed through a prediction-based super twisting sliding mode control (ST-SMC) using a state and disturbance observer. The proposed design achieves finite time convergence of frequency and tie line power deviation. The said design is validated under ramp and random step disturbance, with nonlinearities like generation rate constraints and governor deadband, with an integration of renewable energy and also with IEEE 39 bus power system. The closed loop stability is proven thanks to candidate Lyapunov function and verified by simulations

    Sliding Mode Observer-Based Finite Time Control Scheme for Frequency Regulation and Economic Dispatch in Power Grids

    Get PDF
    This is the author accepted manuscript. The final version is available from Institute of Electrical and Electronics Engineers via the DOI in this record.In this brief, a novel sliding mode (SM) observer-based scheme is proposed to achieve frequency regulation and economic dispatch (ED) in power grids composed of interconnection of generators and load buses. The ED problem is addressed in two steps. Assuming only the voltage phase angles are measured, in the first step a network of heterogeneous SM observers, suitably interconnected in a distributed fashion, is created to estimate both frequency deviations and unknown power levels associated with each bus. In the second step, the observer scheme is coupled with an SM control strategy which is able to reach the optimal value of the control input in each generator bus in finite time. The scheme is assessed via the IEEE 39 bus benchmark, and a comparison with existing control methods is provided

    A robust load frequency control scheme for power systems based on second-order sliding mode and extended disturbance observer

    No full text
    This paper proposes a new robust load frequency control (LFC) scheme for multiarea power systems based on the second-order sliding mode control and an extended disturbance observer. First, a reduced-order model of the power system LFC is derived. In this model, the load variations and net exchange tie-line power deviations are combined as a lumped disturbance which can be estimated by the extended disturbance observer. Second, a novel sliding surface is designed with the new transformed state variables obtained from the estimated disturbance. The system dynamics can be indicated by sliding surface design using the eigenvalue assignment or the optimal sliding manifold technique. The sliding variable is driven to the sliding surface with a second-order sliding mode algorithm named supertwisting algorithm. The stability of the proposed LFC scheme and the extended disturbance observer is proved using Lyapunov method. The merits of the scheme include faster response speed, stronger robustness against disturbances arising from power system parameter errors, and unmodeled dynamics, and the full consideration of tie-line power flow scheduling variations. Finally, numerical simulations verify the effectiveness of the LFC scheme and reveal its advantages over the state of the arts.MOE (Min. of Education, S’pore

    A Hankel Matrix Based Reduced Order Model for Stability Analysis of Hybrid Power System Using PSO-GSA Optimized Cascade PI-PD Controller for Automatic Load Frequency Control

    Get PDF
    This paper presents the automatic load frequency control (ALFC) of two-area multisource hybrid power system (HPS). The interconnected HPS model consists of conventional and renewable energy sources operating in disparate combinations to balance the generation and load demand of the system. In the proffered work, the stability analysis of nonlinear dynamic HPS model was analyzed using the Hankel method of model order reduction. Also, an attempt was made to apply cascade proportional integral - proportional derivative (PI-PD) control for HPS. The gains of the controller were optimized by minimizing the integral absolute error (IAE) of area control error using particle swarm optimization-gravitational search algorithm (PSO-GSA) optimization technique. The performance of cascade control was compared with other classical controllers and the efficiency of this approach was studied for various cases of HPS model. The result shows that the cascade control produced better transient and steady state performances than those of the other classical controllers. The robustness analysis also reveals that the system overshoots/undershoots in frequency response pertaining to random change in wind power generation and load perturbations were significantly reduced by the proposed cascade control. In addition, the sensitivity analysis of the system was performed, with the variation in step load perturbation (SLP) of 1% to 5%, system loading and inertia of the system by ±25% of nominal values to prove the efficiency of the controller. Furthermore, to prove the efficiency of PSO-GSA tuned cascade control, the results were compared with other artificial intelligence (AI) methods presented in the literature. Further, the stability of the system was analyzed in frequency domain for different operating cases
    corecore