47 research outputs found

    Ventricular Fibrillation and Tachycardia Detection Using Features Derived from Topological Data Analysis

    Get PDF
    A rapid and accurate detection of ventricular arrhythmias is essential to take appropriate therapeutic actions when cardiac arrhythmias occur. Furthermore, the accurate discrimination between arrhythmias is also important, provided that the required shocking therapy would not be the same. In this work, the main novelty is the use of the mathematical method known as Topological Data Analysis (TDA) to generate new types of features which can contribute to the improvement of the detection and classification performance of cardiac arrhythmias such as Ventricular Fibrillation (VF) and Ventricular Tachycardia (VT). The electrocardiographic (ECG) signals used for this evaluation were obtained from the standard MIT-BIH and AHA databases. Two input data to the classify are evaluated: TDA features, and Persistence Diagram Image (PDI). Using the reduced TDA-obtained features, a high average accuracy near 99% was observed when discriminating four types of rhythms (98.68% to VF; 99.05% to VT; 98.76% to normal sinus; and 99.09% to Other rhythms) with specificity values higher than 97.16% in all cases. In addition, a higher accuracy of 99.51% was obtained when discriminating between shockable (VT/VF) and non-shockable rhythms (99.03% sensitivity and 99.67% specificity). These results show that the use of TDA-derived geometric features, combined in this case this the k-Nearest Neighbor (kNN) classifier, raises the classification performance above results in previous works. Considering that these results have been achieved without preselection of ECG episodes, it can be concluded that these features may be successfully introduced in Automated External Defibrillation (AED) and Implantable Cardioverter Defibrillation (ICD) therapie

    Mixing Bandt-Pompe and Lempel-Ziv approaches: another way to analyze the complexity of continuous-states sequences

    Get PDF
    In this paper, we propose to mix the approach underlying Bandt-Pompe permutation entropy with Lempel-Ziv complexity, to design what we call Lempel-Ziv permutation complexity. The principle consists of two steps: (i) transformation of a continuous-state series that is intrinsically multivariate or arises from embedding into a sequence of permutation vectors, where the components are the positions of the components of the initial vector when re-arranged; (ii) performing the Lempel-Ziv complexity for this series of `symbols', as part of a discrete finite-size alphabet. On the one hand, the permutation entropy of Bandt-Pompe aims at the study of the entropy of such a sequence; i.e., the entropy of patterns in a sequence (e.g., local increases or decreases). On the other hand, the Lempel-Ziv complexity of a discrete-state sequence aims at the study of the temporal organization of the symbols (i.e., the rate of compressibility of the sequence). Thus, the Lempel-Ziv permutation complexity aims to take advantage of both of these methods. The potential from such a combined approach - of a permutation procedure and a complexity analysis - is evaluated through the illustration of some simulated data and some real data. In both cases, we compare the individual approaches and the combined approach.Comment: 30 pages, 4 figure

    Decreased Lempel-Ziv complexity in Alzheimer's disease patients' magnetoencephalograms

    Get PDF
    The aim of the present research is to study the magnetoencephalogram (MEG) background activity in patients with Alzheimer's disease (AD) using the Lempel-Ziv (LZ) complexity. We recorded the MEG with a 148-channel whole-head magnetometer (MAGNES 2500 WH, 4D Neuroimaging) in 10 patients with probable AD and 10 age-matched control subjects, during five minutes. Artefact-free epochs were selected for the non-linear analysis. In all MEG channels, the AD patients had lower complexity than control subjects. In 77 of them the differences were statistically significant (p < 0.01). These preliminary results suggest that cognitive dysfunction in AD is associated with a decreased complexity in certain regions of the brain

    Towards the text compression based feature extraction in high impedance fault detection

    Get PDF
    High impedance faults of medium voltage overhead lines with covered conductors can be identified by the presence of partial discharges. Despite it is a subject of research for more than 60 years, online partial discharges detection is always a challenge, especially in environment with heavy background noise. In this paper, a new approach for partial discharge pattern recognition is presented. All results were obtained on data, acquired from real 22 kV medium voltage overhead power line with covered conductors. The proposed method is based on a text compression algorithm and it serves as a signal similarity estimation, applied for the first time on partial discharge pattern. Its relevancy is examined by three different variations of classification model. The improvement gained on an already deployed model proves its quality.Web of Science1211art. no. 214

    Prediction of Paroxysmal Atrial Fibrillation From Complexity Analysis of the Sinus Rhythm ECG: A Retrospective Case/Control Pilot Study.

    Get PDF
    Paroxysmal atrial fibrillation (PAF) is the most common cardiac arrhythmia, conveying a stroke risk comparable to persistent AF. It poses a significant diagnostic challenge given its intermittency and potential brevity, and absence of symptoms in most patients. This pilot study introduces a novel biomarker for early PAF detection, based upon analysis of sinus rhythm ECG waveform complexity. Sinus rhythm ECG recordings were made from 52 patients with (n = 28) or without (n = 24) a subsequent diagnosis of PAF. Subjects used a handheld ECG monitor to record 28-second periods, twice-daily for at least 3 weeks. Two independent ECG complexity indices were calculated using a Lempel-Ziv algorithm: R-wave interval variability (beat detection, BD) and complexity of the entire ECG waveform (threshold crossing, TC). TC, but not BD, complexity scores were significantly greater in PAF patients, but TC complexity alone did not identify satisfactorily individual PAF cases. However, a composite complexity score (h-score) based on within-patient BD and TC variability scores was devised. The h-score allowed correct identification of PAF patients with 85% sensitivity and 83% specificity. This powerful but simple approach to identify PAF sufferers from analysis of brief periods of sinus-rhythm ECGs using hand-held monitors should enable easy and low-cost screening for PAF with the potential to reduce stroke occurrence

    Reliability of old and new ventricular fibrillation detection algorithms for automated external defibrillators

    Get PDF
    BACKGROUND: A pivotal component in automated external defibrillators (AEDs) is the detection of ventricular fibrillation by means of appropriate detection algorithms. In scientific literature there exists a wide variety of methods and ideas for handling this task. These algorithms should have a high detection quality, be easily implementable, and work in real time in an AED. Testing of these algorithms should be done by using a large amount of annotated data under equal conditions. METHODS: For our investigation we simulated a continuous analysis by selecting the data in steps of one second without any preselection. We used the complete BIH-MIT arrhythmia database, the CU database, and the files 7001 – 8210 of the AHA database. All algorithms were tested under equal conditions. RESULTS: For 5 well-known standard and 5 new ventricular fibrillation detection algorithms we calculated the sensitivity, specificity, and the area under their receiver operating characteristic. In addition, two QRS detection algorithms were included. These results are based on approximately 330 000 decisions (per algorithm). CONCLUSION: Our values for sensitivity and specificity differ from earlier investigations since we used no preselection. The best algorithm is a new one, presented here for the first time

    Study on the non-linear metrics contribution to estimate atrial fibrillation organization from the surface electrocardiogram

    Full text link
    [EN] Atrial fibrillation (AF) is the most frequently diagnosed arrhythmia, characterized by an uncoordinated atrial electrical activation, thus causing the atria to be unable to pump blood effectively. The prevalence of AF is expected to increase significantly in the next decades as the population ages. However, both the knowledge and the treatment of this arrhythmia still have to experiment a significant progress. Previous studies have reported that AF organization, which can be defined as the repetitiveness degree of the atrial activity pattern, correlates with the arrhythmia status as well as with the therapy outcome. Thus, estimating AF organization from surface electrocardiographic (ECG) recordings constitutes a very interesting approach because ECG recordings are easy and cheap to obtain. The objective of this doctoral thesis is to assess the use of a variety of nonlinear indices in the estimation of AF organization from single-lead noninvasive ECG recordings. Apart from the most common noninvasive AF organization estimators, such as Sample Entropy (SampEn) and the dominant atrial frequency (DAF), the following nonlinear indices have been studied: Fuzzy Entropy, Spectral Entropy, Lempel-Ziv Complexity and Hurst Exponents. Moreover, since the presence of noise and ventricular residuals affects the performance of nonlinear methods, the application of a strategy aimed at reducing these nuisances has been evaluated. Therefore, the application of these metrics over the atrial activity fundamental waveform, named the main atrial wave (MAW), has been proposed. In this doctoral thesis, the following scenarios involving AF organization have been considered: the prediction of paroxysmal AF spontaneous termination, the study of the earlier signs anticipating AF termination and the classification between paroxysmal and persistent AF from short ECG recordings. Firstly, the performance of the studied metrics discriminating events related to AF organization was tested making use of a reference database aimed at predicting AF spontaneous termination. In this study, most of the proposed indices provided higher accuracy than traditional AF organization estimators. Accuracy values higher than 90% were obtained with several indices. In particular, the generalized Hurst exponents of order 1 and 2, H(1) and H(2), achieved outstanding results, thus being selected for later studies in this thesis. Furthermore, the computation of H(2) depends on two critical parameters, namely, the analyzed interval length (L) and the maximum search window for self-similarities (tau). Hence, a study with 660 combinations on these two parameters was performed, together with the sampling frequency (fs) of the recording, in order to obtain their optimal combination in computing AF organization. On the other hand, previous works analyzing the spontaneous termination of AF have been only focused on the last 2 minutes preceding the termination. In contrast, a different scenario considering longer recordings to detect the earlier signs anticipating paroxysmal AF termination has been analyzed for the first time in this thesis. H(2) was selected for the study because of its highest accuracy in AF termination prediction. Additionally, the DAF and SampEn were also computed as references. Through this study it has been corroborated that AF organization only varies significantly within the last 3 minutes before spontaneous termination. As a consequence, the early prediction of paroxysmal AF spontaneous termination does not seem feasible through the current signal analysis tools. Finally, H(2) was applied in the classification between paroxysmal and persistent AF from short ECG recordings, achieving a higher diagnostic accuracy than DAF and SampEn. This result suggests that the analysis of ambulatory ECG recordings through H(2) could be a future alternative to the use of Holter ECG recordings in the classification between paroxysmal and persistent AF.[ES] La fibrilación auricular (FA) es la arritmia más frecuente y se caracteriza por una actividad auricular descoordinada, que impide que las aurículas bombeen sangre de manera eficaz. Se espera que la prevalencia de la FA aumente significativamente en las próximas décadas debido al envejecimiento de la población. Sin embargo, tanto el conocimiento relativo a esta arritmia como su tratamiento son todavía mejorables. Estudios previos han relacionado la organización de la FA, que se puede definir como el grado de repetitividad de la actividad auricular, con el estado de la arritmia o su respuesta al tratamiento. Además, la estimación de la organización de la FA a partir de registros electrocardiográficos (ECG) de superficie resulta especialmente interesante porque su obtención es sencilla y barata. El objetivo de esta tesis doctoral es evaluar el uso de distintos índices no lineales para estimar la organización de la FA a partir del ECG. Además de los estimadores no invasivos de organización más comunes, como la entropía muestral (SampEn) y la frecuencia auricular dominante (DAF), se han estudiado los siguientes métodos no lineales: la entropía borrosa, la entropía espectral, la complejidad Lempel-Ziv y los exponentes de Hurst. Además, se ha estudiado el uso de una estrategia destinada a la reducción del ruido y los residuos de actividad ventricular para mejorar el desempeño de métodos no lineales. Así, los índices estudiados también se han aplicado sobre la forma de onda fundamental de la actividad auricular, conocida como la onda auricular principal (MAW). Se han considerado los siguientes escenarios relacionados con la organización de la FA: la predicción de la terminación espontánea de la FA paroxística, el estudio de los primeros indicios de terminación espontánea de la FA y la clasificación entre FA paroxística y FA persistente a partir de registros ECG de corta duración. Primero, se estudió la capacidad de los índices estudiados para distinguir eventos relacionados con la organización de la FA mediante el análisis de una base de datos de referencia para la predicción de su terminación espontánea. La mayoría de los índices propuestos consiguieron una mayor precisión que los estimadores tradicionales de organización. Así, varios de los índices obtuvieron una precisión superior al 90% en la predicción de la terminación espontánea de la FA. En particular, los exponentes de Hurst generalizados de orden 1 y 2, H(1) y H(2), lograron los mejores resultados de clasificación. Puesto que el cálculo de H(2) depende de dos parámetros críticos, la longitud del intervalo analizado (L) y el tamaño máximo de la ventana donde buscar similitudes (tau), se llevó a cabo un estudio con 660 combinaciones de esos dos parámetros junto con la frecuencia de muestreo (fs) del registro para determinar el uso óptimo de este índice. Por otra parte, los trabajos previos que han estudiado la terminación espontánea de la FA se han centrado en los últimos 2 minutos antes de la terminación. Por contra, en esta tesis doctoral se han estudiado por primera vez registros de mayor duración para detectar los primeros indicios de la terminación de la FA. Para ello, se eligió el uso de H(2) por su alta precisión en la predicción de la terminación de la FA. Además, la DAF y SampEn se calcularon como referencias. En este estudio se ha comprobado que la organización de la FA solamente presenta variaciones significativas en los últimos 3 minutos antes de su terminación espontánea. Por ello, la predicción temprana de la terminación no parece posible con los medios actuales de análisis de la señal. Por último, se aplicó H(2) para clasificar entre FA paroxística y FA persistente a partir de ECGs de corta duración, obteniendo una mayor precisión diagnóstica que la DAF y SampEn. Este resultado sugiere que el análisis de ECGs ambulatorios por medio de H(2) puede ser en el futuro una alte[CA] La fibril·lació auricular (FA) és l'arítmia més freqüent i es caracteritza per una activitat auricular descoordinada, que impedix que les aurícules bomben sang de manera eficaç. S'espera que la prevalença de la FA augmente significativament en les pròximes dècades a causa de l'envelliment de la població. No obstant això, tant el coneixement relatiu a esta arítmia com el seu tractament són encara millorables. Estudis previs han relacionat l'organització de la FA, que es pot definir com el grau de repetitivitat de l'activitat auricular, amb l'estat de l'arítmia o la seua resposta al tractament. A més, l'estimació de l'organització de la FA a partir de registres electrocardiogràfics (ECG) de superfície resulta especialment interessant perquè la seua obtenció és senzilla i barata. L'objectiu d'esta tesi doctoral és avaluar l'ús de distints índexs no lineals en l'estimació de l'organització de la FA a partir de l'ECG de superfície. A més dels estimadors no invasius d'organització més comuns, com l'entropia mostral (SampEn) i la freqüència auricular dominant (DAF), s'han estudiat els següents mètodes no lineals: l'entropia borrosa, l'entropia espectral, la complexitat Lempel-Ziv i els exponents de Hurst. A més, s'ha estudiat l'ús d'una estratègia destinada a la reducció del soroll i els residus d'activitat ventricular per a millorar la seua capacitat d'estimar l'organització. Així, doncs, els índexs estudiats també s'han aplicat sobre la forma d'onda fonamental de l'activitat auricular, coneguda com l'onda auricular principal (MAW). S'han considerat els següents escenaris relacionats amb l'organització de la FA: la predicció de la terminació espontània de la FA paroxística, l'estudi dels primers indicis de terminació espontània de la FA i la classificació entre FA paroxística i FA persistent a partir de registres ECG de curta duració. Primer, es va estudiar la capacitat dels índexs estudiats per a distingir esdeveniments relacionats amb l'organització de la FA per mitjà de l'anàlisi d'una base de dades de referència per a la predicció de la seua terminació espontània. La majoria dels índexs proposats van aconseguir una major precisió que els estimadors tradicionals d'organització de la FA. Així, alguns dels índexs van obtindre una precisió superior al 90% en la predicció de la terminació espontània de la FA. En particular, els exponents de Hurst generalitzats d'orde 1 i 2, H(1) i H(2), van aconseguir els millors resultats de classificació. Com el càlcul de H(2) depén de dos paràmetres crítics, la longitud de l'interval analitzat (L) i la grandària màxima de la finestra on buscar similituds (tau), es va dur a terme un estudi amb 660 combinacions d'eixos dos paràmetres junt amb la freqüència de mostratge (fs) del registre per a determinar la combinació òptima de valors per a estimar l'organització de la FA. D'altra banda, els treballs previs que han estudiat la terminació espontània de la FA s'han centrat en els últims 2 minuts abans de la terminació. Per contra, en esta tesi doctoral s'han estudiat per primera vegada registres de major duració amb l'objectiu de detectar els primers indicis de la terminació de la FA. Es va triar l'ús de H(2) per a este estudi per la seua alta precisió en la predicció de la terminació de la FA. A més, la DAF i SampEn es van calcular com a referències. En este estudi s'ha comprovat que l'organització de la FA només presenta variacions significatives en els últims 3 minuts abans de la seua terminació espontània. Per això, la predicció primerenca de la terminació no pareix possible amb els mitjans actuals d'anàlisi del senyal. Finalment, es va aplicar H(2) per a classificar entre FA paroxística i FA persistent a partir d'ECGs de curta duració, obtenint una millor precisió diagnòstica que amb la DAF i SampEn. Este resultat suggerix que l'anàlisi d'ECGs ambulatoris per mitjà de H(2) pot ser en eJulián Seguí, M. (2015). Study on the non-linear metrics contribution to estimate atrial fibrillation organization from the surface electrocardiogram [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/56150TESI