322 research outputs found

    An Ultralow Power Multirate FSK Demodulator With Digital-Assisted Calibrated Delay-Line Based Phase Shifter for High-Speed Biomedical Zero-IF Receivers

    Get PDF
    [[abstract]]頻率鍵移接收解調電路可廣泛應用於穿戴式或植入式生理訊號感測器與各種環境監測之成測器上,其其有超低功率消耗與抗干擾能力強之優點,因此可大幅增加成測器之使用壽命並提供可靠與穩定之資料傳輸品質。本論文提出一高速、可變傳輸速率與超低功耗之頻率鍵移接收解調電路設計。突破先前頻率鍵移解調電路最高解調速度為10 Mb/s 之限制,傳輸速率可達40 Mb/s 以上,因此可大幅降低接收每位元資料所需之能源消耗,提高能源效率。此電路架構可根據使用需求調整其傳輸速率範園1 Mb/s-40 Mb/s,以達到功耗與傳輸速率最佳化之目的。[[notice]]補正完畢[[incitationindex]]SCI[[booktype]]紙

    Low power CMOS IC, biosensor and wireless power transfer techniques for wireless sensor network application

    Get PDF
    The emerging field of wireless sensor network (WSN) is receiving great attention due to the interest in healthcare. Traditional battery-powered devices suffer from large size, weight and secondary replacement surgery after the battery life-time which is often not desired, especially for an implantable application. Thus an energy harvesting method needs to be investigated. In addition to energy harvesting, the sensor network needs to be low power to extend the wireless power transfer distance and meet the regulation on RF power exposed to human tissue (specific absorption ratio). Also, miniature sensor integration is another challenge since most of the commercial sensors have rigid form or have a bulky size. The objective of this thesis is to provide solutions to the aforementioned challenges

    Wireless Telemetry for Implantable Biomedical Microsystems

    Get PDF

    Next generation RFID telemetry design for biomedical implants.

    Get PDF
    The design and development of a Radio Frequency Identification (RFID) based pressure-sensing system to increase the range of current Intra-Ocular Pressure (IOP) sensing systems is described in this dissertation. A large number of current systems use near-field inductive coupling for the transfer of energy and data, which limits the operational range to only a few centimeters and does not allow for continuous monitoring of pressure. Increasing the powering range of the telemetry system will offer the possibility of continuous monitoring since the reader can be attached to a waist belt or put on a night stand when sleeping. The system developed as part of this research operates at Ultra-High Frequencies (UHF) and makes use of the electromagnetic far field to transfer energy and data, which increases the potential range of operation and allows for the use of smaller antennas. The system uses a novel electrically small antenna (ESA) to receive the incident RF signal. A four stage Schottky circuit rectifies and multiplies the received RF signal and provides DC power to a Colpitts oscillator. The oscillator is connected to a pressure sensor and provides an output signal frequency that is proportional to the change in pressure. The system was fabricated using a mature, inexpensive process. The performance of the system compares well with current state of the art, but uses a smaller antenna and a less expensive fabrication process. The system was able to operate over the desired range of 1 m using a half-wave dipole antenna. It was possible to power the system over a range of at least 6.4 cm when the electrically small antenna was used as the receiving antenna

    Low-Power High-Data-Rate Transmitter Design for Biomedical Application

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH

    System-on-Package Low-Power Telemetry and Signal Conditioning unit for Biomedical Applications

    Get PDF
    Recent advancements in healthcare monitoring equipments and wireless communication technologies have led to the integration of specialized medical technology with the pervasive wireless networks. Intensive research has been focused on the development of medical wireless networks (MWN) for telemedicine and smart home care services. Wireless technology also shows potential promises in surgical applications. Unlike conventional surgery, an expert surgeon can perform the surgery from a remote location using robot manipulators and monitor the status of the real surgery through wireless communication link. To provide this service each surgical tool must be facilitated with smart electronics to accrue data and transmit the data successfully to the monitoring unit through wireless network. To avoid unwieldy wires between the smart surgical tool and monitoring units and to reap the benefit of excellent features of wireless technology, each smart surgical tool must incorporate a low-power wireless transmitter. Low-power transmitter with high efficiency is essential for short range wireless communication. Unlike conventional transmitters used for cellular communication, injection-locked transmitter shows greater promises in short range wireless communication. The core block of an injection-locked transmitter is an injection-locked oscillator. Therefore, this research work is directed towards the development of a low-voltage low-power injection-locked oscillator which will facilitate the development of a low-power injection-locked transmitter for MWN applications. Structure of oscillator and types of injection are two crucial design criteria for low-power injection-locked oscillator design. Compared to other injection structures, body-level injection offers low-voltage and low-power operation. Again, conventional NMOS/PMOS-only cross-coupled LC oscillator can work with low supply voltage but the power consumption is relatively high. To overcome this problem, a self-cascode LC oscillator structure has been used which provides both low-voltage and low-power operation. Body terminal coupling is used with this structure to achieve injection-locking. Simulation results show that the self-cascode structure consumes much less power compared to that of the conventional structure for the same output swing while exhibiting better phase noise performance. Usage of PMOS devices and body bias control not only reduces the flicker noise and power consumption but also eliminates the requirements of expensive fabrication process for body terminal access

    A Multi-Channel Low-Power System-on-Chip for in Vivo Recording and Wireless Transmission of Neural Spikes

    Get PDF
    This paper reports a multi-channel neural spike recording system-on-chip with digital data compression and wireless telemetry. The circuit consists of 16 amplifiers, an analog time-division multiplexer, a single 8 bit analog-to-digital converter, a digital signal compression unit and a wireless transmitter. Although only 16 amplifiers are integrated in our current die version, the whole system is designed to work with 64, demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. Compression of the raw data is achieved by detecting the action potentials (APs) and storing 20 samples for each spike waveform. This compression method retains sufficiently high data quality to allow for single neuron identification (spike sorting). The 400 MHz transmitter employs a Manchester-Coded Frequency Shift Keying (MC-FSK) modulator with low modulation index. In this way, a 1.25 Mbit/s data rate is delivered within a limited band of about 3 MHz. The chip is realized in a 0.35 um AMS CMOS process featuring a 3 V power supply with an area of 3.1x 2.7 mm2. The achieved transmission range is over 10 m with an overall power consumption for 64 channels of 17.2 mW. This figure translates into a power budget of 269uW per channel, in line with published results but allowing a larger transmission distance and more efficient bandwidth occupation of the wireless link. The integrated circuit was mounted on a small and light board to be used during neuroscience experiments with freely-behaving rats. Powered by 2 AAA batteries, the system can continuously work for more than 100 hours allowing for long-lasting neural spike recordings

    Micropower circuits for bidirectional wireless telemetry in neural recording applications

    Get PDF
    Journal ArticleState-of-the art neural recording systems require electronics allowing for transcutaneous, bidirectional data transfer. As these circuits will be implanted near the brain, they must be small and low power. We have developed micropower integrated circuits for recovering clock and data signals over a transcutaneous power link. The data recovery circuit produces a digital data signal from an ac power waveform that has been amplitude modulated. We have also developed an FM transmitter with the lowest power dissipation reported for biosignal telemetry. The FM transmitter consists of a low-noise biopotential amplifier and a voltage controlled oscillator used to transmit amplified neural signals at a frequency near 433 MHz. All circuits were fabricated in a standard 0.5- m CMOS VLSI process. The resulting chip is powered through a wireless inductive link. The power consumption of the clock and data recovery circuits is measured to be 129 W; the power consumption of the transmitter is measured to be 465 W when using an external surface mount inductor. Using a parasitic antenna less than 2 mm long, a received power level was measured to be 59 73 dBmat a distance of one meter

    INJECTION-LOCKING TECHNIQUES FOR MULTI-CHANNEL ENERGY EFFICIENT TRANSMITTER

    Get PDF
    Ph.DDOCTOR OF PHILOSOPH
    corecore