2,143 research outputs found

    Silicon switching transistor with high power and low saturation voltage

    Get PDF
    Assembly of two individually encapsulated silicon-chip transistors produces silicon power-transistor that has low electrical resistance and low thermal impedance. Electrical resistance and thermal impedance are low because of short lead lengths, and external contact surfaces are plated to reduce resistance at interfaces

    Study of variable thermal impedance devices

    Get PDF
    Variable thermal impedance devices with application to strapdown inertial sensing unit subassembl

    Tomographic imaging and scanning thermal microscopy: thermal impedance tomography

    Get PDF
    The application of tomographic imaging techniques developed for medical applications to the data provided by the scanning thermal microscope will give access to true three-dimensional information on the thermal properties of materials on a mm length scale. In principle, the technique involves calculating and inverting a sensitivity matrix for a uniform isotropic material, collecting ordered data at several modulation frequencies, and multiplying the inverse of the matrix with the data vector. In practice, inversion of the matrix in impractical, and a novel iterative technique is used. Examples from both simulated and real data are given

    Frequency Dependent Specific Heat from Thermal Effusion in Spherical Geometry

    Get PDF
    We present a novel method of measuring the frequency dependent specific heat at the glass transition applied to 5-polyphenyl-4-ether. The method employs thermal waves effusing radially out from the surface of a spherical thermistor that acts as both a heat generator and thermometer. It is a merit of the method compared to planar effusion methods that the influence of the mechanical boundary conditions are analytically known. This implies that it is the longitudinal rather than the isobaric specific heat that is measured. As another merit the thermal conductivity and specific heat can be found independently. The method has highest sensitivity at a frequency where the thermal diffusion length is comparable to the radius of the heat generator. This limits in practise the frequency range to 2-3 decades. An account of the 3omega-technique used including higher order terms in the temperature dependency of the thermistor and in the power generated is furthermore given.Comment: 17 pages, 15 figures, Substantially revised versio

    Parameterized thermal macromodeling for fast and effective design of electronic components and systems

    Get PDF
    We present a parameterized macromodeling approach to perform fast and effective dynamic thermal simulations of electronic components and systems where key design parameters vary. A decomposition of the frequency-domain data samples of the thermal impedance matrix is proposed to improve the accuracy of the model and reduce the number of the computationally costly thermal simulations needed to build the macromodel. The methodology is successfully applied to analyze the impact of layout variations on the dynamic thermal behavior of a state-of-the-art 8-finger AlGaN/GaN HEMT grown on a SiC substrate

    Dynamic Thermal Analysis of a Power Amplifier

    Get PDF
    This paper presents dynamic thermal analyses of a power amplifier. All the investigations are based on the transient junction temperature measurements performed during the circuit cooling process. The presented results include the cooling curves, the structure functions, the thermal time constant distribution and the Nyquist plot of the thermal impedance. The experiments carried out demonstrated the influence of the contact resistance and the position of the entire cooling assembly on the obtained results.Comment: Submitted on behalf of TIMA Editions (http://irevues.inist.fr/tima-editions

    Hybrid III-V/Si distributed-feedback laser based on adhesive bonding

    Get PDF
    A hybrid evanescently coupled III-V/silicon distributed-feedback laser with an integrated monitor photodiode, based on adhesive divinyl siloxane-benzocyclobutene bonding and emitting at 1310 nm, is presented. An output power of similar to 2.85 mW is obtained in a continuous wave regime at 10 degrees C. The threshold current is 20 mA and a sidemode suppression ratio of 45 dB is demonstrated. Optical feedback is provided via corrugations on top of the silicon rib waveguide, while a specially developed bonding procedure yields 40-nm-thick adhesive bonding layers, enabling efficient evanescent coupling

    Effective electrothermal analysis of electronic devices and systems with parameterized macromodeling

    Get PDF
    We propose a parameterized macromodeling methodology to effectively and accurately carry out dynamic electrothermal (ET) simulations of electronic components and systems, while taking into account the influence of key design parameters on the system behavior. In order to improve the accuracy and to reduce the number of computationally expensive thermal simulations needed for the macromodel generation, a decomposition of the frequency-domain data samples of the thermal impedance matrix is proposed. The approach is applied to study the impact of layout variations on the dynamic ET behavior of a state-of-the-art 8-finger AlGaN/GaN high-electron mobility transistor grown on a SiC substrate. The simulation results confirm the high accuracy and computational gain obtained using parameterized macromodels instead of a standard method based on iterative complete numerical analysis
    corecore