2,236 research outputs found

    Accuracy of elastic fusion biopsy in daily practice: results of a multicenter study of 2115 patients

    Get PDF
    OBJECTIVES: To assess the accuracy of Koelis fusion biopsy for the detection of prostate cancer and clinically significant prostate cancer in the everyday practice. METHODS: We retrospectively enrolled 2115 patients from 15 institutions in four European countries undergoing transrectal Koelis fusion biopsy from 2010 to 2017. A variable number of target (usually 2-4) and random cores (usually 10-14) were carried out, depending on the clinical case and institution habits. The overall and clinically significant prostate cancer detection rates were assessed, evaluating the diagnostic role of additional random biopsies. The cancer detection rate was correlated to multiparametric magnetic resonance imaging features and clinical variables. RESULTS: The mean number of targeted and random cores taken were 3.9 (standard deviation 2.1) and 10.5 (standard deviation 5.0), respectively. The cancer detection rate of Koelis biopsies was 58% for all cancers and 43% for clinically significant prostate cancer. The performance of additional, random cores improved the cancer detection rate of 13% for all cancers (P < 0.001) and 9% for clinically significant prostate cancer (P < 0.001). Prostate cancer was detected in 31%, 66% and 89% of patients with lesions scored as Prostate Imaging Reporting and Data System 3, 4 and 5, respectively. Clinical stage and Prostate Imaging Reporting and Data System score were predictors of prostate cancer detection in multivariate analyses. Prostate-specific antigen was associated with prostate cancer detection only for clinically significant prostate cancer. CONCLUSIONS: Koelis fusion biopsy offers a good cancer detection rate, which is increased in patients with a high Prostate Imaging Reporting and Data System score and clinical stage. The performance of additional, random cores seems unavoidable for correct sampling. In our experience, the Prostate Imaging Reporting and Data System score and clinical stage are predictors of prostate cancer and clinically significant prostate cancer detection; prostate-specific antigen is associated only with clinically significant prostate cancer detection, and a higher number of biopsy cores are not associated with a higher cancer detection rate

    The primacy of multiparametric MRI in men with suspected prostate cancer

    Get PDF
    Background: Multiparametric MRI (mpMRI) became recognised in investigating those with suspected prostate cancer between 2010 and 2012; in the USA, the preventative task force moratorium on PSA screening was a strong catalyst. In a few short years, it has been adopted into daily urological and oncological practice. The pace of clinical uptake, born along by countless papers proclaiming high accuracy in detecting clinically significant prostate cancer, has sparked much debate about the timing of mpMRI within the traditional biopsy-driven clinical pathways. There are strongly held opposing views on using mpMRI as a triage test regarding the need for biopsy and/or guiding the biopsy pattern. Objective: To review the evidence base and present a position paper on the role of mpMRI in the diagnosis and management of prostate cancer. Methods: A subgroup of experts from the ESUR Prostate MRI Working Group conducted literature review and face to face and electronic exchanges to draw up a position statement. Results: This paper considers diagnostic strategies for clinically significant prostate cancer; current national and international guidance; the impact of pre-biopsy mpMRI in detection of clinically significant and clinically insignificant neoplasms; the impact of pre-biopsy mpMRI on biopsy strategies and targeting; the notion of mpMRI within a wider risk evaluation on a patient by patient basis; the problems that beset mpMRI including inter-observer variability. Conclusions: The paper concludes with a set of suggestions for using mpMRI to influence who to biopsy and who not to biopsy at diagnosis. Key Points: • Adopt mpMRI as the first, and primary, investigation in the workup of men with suspected prostate cancer. • PI-RADS assessment categories 1 and 2 have a high negative predictive value in excluding significant disease, and systematic biopsy may be postponed, especially in men with low-risk of disease following additional risk stratification. • PI-RADS assessment category lesions 4 and 5 should be targeted; PI-RADS assessment category lesion 3 may be biopsied as a target, as part of systematic biopsies or may be observed depending on risk stratification

    Cylindrical illumination with angular coupling for whole-prostate photoacoustic tomography

    Get PDF
    Current diagnosis of prostate cancer relies on histological analysis of tissue samples acquired by biopsy, which could benefit from real-time identification of suspicious lesions. Photoacoustic tomography has the potential to provide real-time targets for prostate biopsy guidance with chemical selectivity, but light delivered from the rectal cavity has been unable to penetrate to the anterior prostate. To overcome this barrier, a urethral device with cylindrical illumination is developed for whole-prostate imaging, and its performance as a function of angular light coupling is evaluated with a prostate-mimicking phantom

    Evaluation of T1 relaxation time in prostate cancer and benign prostate tissue using a Modified Look-Locker inversion recovery sequence

    Get PDF
    Purpose of this study was to evaluate the diagnostic performance of T1 relaxation time (T1) for differentiating prostate cancer (PCa) from benign tissue as well as high- from low-grade PCa. Twenty-three patients with suspicion for PCa were included in this prospective study. 3 T MRI including a Modified Look-Locker inversion recovery sequence was acquired. Subsequent targeted and systematic prostate biopsy served as a reference standard. T1 and apparent diffusion coefficient (ADC) value in PCa and reference regions without malignancy as well as high- and low-grade PCa were compared using the Mann-Whitney U test. The performance of T1, ADC value, and a combination of both to differentiate PCa and reference regions was assessed by receiver operating characteristic (ROC) analysis. T1 and ADC value were lower in PCa compared to reference regions in the peripheral and transition zone (p < 0.001). ROC analysis revealed high AUCs for T1 (0.92; 95%-CI, 0.87-0.98) and ADC value (0.97; 95%-CI, 0.94 to 1.0) when differentiating PCa and reference regions. A combination of T1 and ADC value yielded an even higher AUC. The difference was statistically significant comparing it to the AUC for ADC value alone (p = 0.02). No significant differences were found between high- and low-grade PCa for T1 (p = 0.31) and ADC value (p = 0.8). T1 relaxation time differs significantly between PCa and benign prostate tissue with lower T1 in PCa. It could represent an imaging biomarker for PCa

    Negative multiparametric magnetic resonance imaging for prostate cancer: what's next?

    Get PDF
    Multiparametric magnetic resonance imaging (mpMRI) of the prostate has excellent sensitivity in detecting clinically significant prostate cancer (csPCa). Nevertheless, the clinical utility of negative mpMRI (nMRI) is less clearMultiparametric magnetic resonance imaging (mpMRI) of the prostate has excellent sensitivity in detecting clinically significant prostate cancer (csPCa). Nevertheless, the clinical utility of negative mpMRI (nMRI) is less clear. OBJECTIVE: To assess outcomes of men with nMRI and clinical follow-up after 7 yr of activity at a reference center. DESIGN, SETTING, AND PARTICIPANTS: All mpMRI performed from January 2010 to May 2015 were reviewed. We selected all patients with nMRI and divided them in group A (naïve patients) and group B (previous negative biopsy). All patients without a diagnosis of PCa had a minimum follow-up of 2 yr and at least two consecutive nMRI. Patients with positive mpMRI were also identified to assess their biopsy outcomes. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: A Kaplan-Meier analysis was performed to assess both any-grade PCa and csPCa diagnosis-free survival probabilities. Univariable and multivariable Cox regression models were fitted to identify predictors of csPCa diagnosis. RESULTS AND LIMITATIONS: We identified 1545 men with nMRI, and 1255 of them satisfied the inclusion criteria; 659 belonged to group A and 596 to group B. Any-grade PCa and csPCa diagnosis-free survival probabilities after 2 yr of follow-up were 94% and 95%, respectively, in group A; in group B, they were 96%. After 48 mo of follow-up, any-grade PCa diagnosis-free survival probability was 84% in group A and 96% in group B (log rank p&lt;0.001). Diagnosis-free survival probability for csPCa was unchanged after 48 mo of follow-up. On multivariable Cox regression analysis, increasing age (p=0.005) was an independent predictor of lower csPCa diagnosis probability, while increasing prostate-specific antigen (PSA) and PSA density (&lt;0.001) independently predicted higher csPCa diagnosis probability. The prevalence of and positive predictive value for csPCa were 31.6% and 45.5%, respectively. Limitations include limited follow-up and the inability to calculate true csPCa prevalence in the study population. CONCLUSIONS: mpMRI is highly reliable to exclude csPCa. Nevertheless, systematic biopsy should be recommended even after nMRI, especially in younger patients with high or raising PSA levels

    Accuracy of multiparametric magnetic resonance imaging to detect significant prostate cancer and index lesion location

    Get PDF
    Background: Multiparametric magnetic resonance imaging (mpMRI) of the prostate appears to improve prostate cancer detection, but studies comparing mpMRI to histopathology at the time of radical prostatectomy (RP) are lacking. This retrospective study determined the accuracy of mpMRI predicting Gleason score and index lesion location at the time of RP, the current gold standard for diagnosis. Methods: Between April 2013 and April 2016, a database of all men aged more than 40 years who underwent RP after positive transrectal ultrasound biopsy by an experienced urological surgeon was collated at a single regional centre. This was cross‐referenced with a database of all men who had mpMRIs performed at a single centre and reported according to Prostate Imaging Reporting and Data System (PI‐RADS version 1) during this period to generate a sample size of 64 men. A Spearman\u27s rho test was utilized to calculate correlation. Results: Median age of patients was 64 years, the median prostate‐specific antigen at RP was 6.22 ng/mL. mpMRI was positive (≥PI‐RADS 3) in 85.9% of patients who underwent RP. More than 92% of participants had Gleason ≥7 disease. A positive relationship between mpMRI prostate PI‐RADS score and RP cancer volume was demonstrated. An anatomical location correlation calculated in octants was found to be 89.1% accurate. Conclusion: mpMRI accurately detects prostate cancer location and severity when compared with gold standard histopathology at the time of RP. It thus has an important role in planning for future prostate biopsy and cancer treatment
    corecore