12,976 research outputs found

    The impact of the AO foundation on fracture care : an evaluation of 60 years AO foundation

    Get PDF
    Objectives Sixty years ago, the Association of Osteosynthesis (AO) was founded with the aim to improve fracture treatment and has since grown into one of the largest medical associations worldwide. Aim of this study was to evaluate AO's impact on science, education, patient care and the MedTech business. Design/methods Impact evaluations were conducted as appropriate for the individual domains: Impact on science was measured by analyzing citation frequencies of publications promoted by AO. Impact on education was evaluated by analyzing the evolution of number and location of AO courses. Impact on patient care was evaluated with a health economic model analyzing cost changes and years of life gained through the introduction of osteosynthesis in 17 high-income countries (HICs). Impact on MedTech business was evaluated by analyzing sales data of AO-associated products. Results Thirty-five AO papers and 2 major AO textbooks are cited at remarkable frequencies in high ranking journals with up to 2000 citations/year. The number of AO courses steadily increased with a total of 645'000 participants, 20‘000 teaching days and 2‘500 volunteer faculty members so far. The introduction of osteosynthesis saved at least 925 billion Swiss Francs [CHF] in the 17 HICs analyzed and had an impact on avoiding premature deaths comparable to the use of antihypertensive drugs. AO-associated products generated sales of 55 billion CHF. Conclusion AO's impact on science, education, patient care, and the MedTech business was significant because AO addressed hitherto unmet needs by combining activities that mutually enriched and reinforced each other

    Strength analyses of screws for femoral neck fractures

    Get PDF
    This article represents a multidisciplinary approach to biomechanics (engineering + medicine) in the field of "collum femoris" fractures. One possible treatment method for femoral neck fractures, especially for young people, is the application of cancellous (i.e. lag or femoral) screws (with full or cannulated cross-section) made of Ti6Al4V or stainless steel. This paper therefore aims to offer our own numerical model of cancellous screws together with an assessment of them. The new, simple numerical model presented here is derived together with inputs and boundary conditions and is characterized by rapid solution. The model is based on the theory of beams on an elastic foundation and on 2nd order theory (set of three differential 4th order equations, combination of pressure and bending stress-deformation states). It presents the process for calculating displacements, slopes, bending moments, stresses etc. Two examples (i.e. combinations of cancellous screws with full or cannulated cross-section made of stainless steel or Ti6Al4V material) are presented and evaluated (i.e. their displacement, slopes, bending moments, normal forces, shearing forces and stresses). Future developments and other applications are also proposed and mentioned.Web of Science38583481

    Computer-aided position planning of miniplates to treat facial bone defects

    Full text link
    In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon's desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time.Comment: 19 pages, 13 Figures, 2 Table

    Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: outcomes and pitfalls in relation to bone mineral density

    Get PDF
    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density

    Comparison of the effect of locking vs standard screws on the mechanical properties of bone-plate constructs in a comminuted diaphyseal fracture model

    Get PDF
    The purpose of this study was to compare the mechanical properties of bone-plate constructs with locking compression plates (LCP) used either with standard screws or with locking screws on an experimental model of comminuted fracture

    Medium-Long-Term Radiographic and Clinical Outcomes after Surgical Treatment of Intra-Articular Tibial Pilon Fractures by Three Different Techniques

    Get PDF
    The goal of this retrospective, observational, case series study was to evaluate the medium-long-term clinical and radiographic results of the three most common surgical osteosynthesis techniques used for the treatment of articular tibial pilon fractures: ORIF, MIPO, and EF. Materials and Methods. A consecutive series of patients with articular pilon fractures who underwent surgery at our institution were enrolled in this study. Fractures were classified according to the M\ufcller AO classification system. Overall outcomes took the following into account: radiographic quality of reduction, evaluated using Ovadia and Beals\u2019 criteria; clinical assessment, evaluated using the AOFAS questionnaire; and general health, evaluated with the SF36-v2 Health Survey. Results. A total of 94 articular pilon fractures (34 type 43-B and 60 43-C) were evaluated with a mean follow-up of 56.34 months (range 33\u2013101). The techniques used were ORIF, MIPO, and EF in 63 (67%), 17 (18.9%), and 14 cases (14.1%), respectively. According to Ovadia and Beals\u2019 criteria, good, fair, and poor results were reported in 61 (64.89%), 26 (27.66%), and 7 (7.45%) cases, respectively. The mean AOFAS score was 82.41 for MIPO, 79.83 for ORIF, and 50.57 for EF, respectively. Thirty-nine patients (41.49%) presented early and/or late complications. Conclusion. Satisfactory outcomes using the three different techniques were reported. In particular, the radiographic outcomes were inversely proportional to the fracture comminutions and statistically different between internal and external osteosynthesis, but comparable between ORIF and MIPO techniques. On the other hand, the clinical outcomes were closely related to the soft tissue conditions and the anatomical reconstruction of the joint

    Complications Associated with Volar Locking Plate Fixation of Distal Radial Fractures.

    Get PDF
    Volar locked plating is the most frequently utilized method for internal fixation of distal radial fractures. The overall complication rate for volar plating of distal radial fractures appears to be relatively low compared with other operative fixation methods. Carpal tunnel syndrome is the most commonly reported complication. However, this may occur after a distal radial fracture regardless of treatment method, with reported rates ranging from 0% to 20% with conservative management and 0% to 14% with volar plating. Extensor tendon rupture has been reported at rates of 0% to 4% and is the most frequent complication requiring plate removal. Variable-angle volar locking plates may be associated with fewer implant-related complications as a result of their greater degree of screw placement customization compared with fixed-angle volar locking plates

    In Vivo Degradation Behavior of the Magnesium Alloy LANd442 in Rabbit Tibiae

    Get PDF
    In former studies the magnesium alloy LAE442 showed promising in vivo degradation behavior and biocompatibility. However, reproducibility might be enhanced by replacement of the rare earth composition metal "E" by only a single rare earth element. Therefore, it was the aim of this study to examine whether the substitution of "E" by neodymium ("Nd") had an influence on the in vivo degradation rate. LANd442 implants were inserted into rabbit tibiae and rabbits were euthanized after 4, 8, 13 and 26 weeks postoperatively. In vivo μCT was performed to evaluate the in vivo implant degradation behaviour by calculation of implant volume, density true 3-D thickness and corrosion rates. Additionally, weight loss, type of corrosion and mechanical stability were appraised by SEM/EDS-analysis and three-point bending tests. Implant volume, density and true 3-D thickness decreased over time, whereas the variance of the maximum diameters within an implant as well as the corrosion rate and weight loss increased. SEM examination revealed mainly pitting corrosion after 26 weeks. The maximum bending forces decreased over time. In comparison to LAE442, the new alloy showed a slower, but more uneven degradation behavior and less mechanical stability. To summarize, LANd442 appeared suitable for low weight bearing bones but is inferior to LAE442 regarding its degradation morphology and strength

    Dual-mobility socket in challenging total hip arthroplasty : 2-6 years follow-up.

    Get PDF
    The success of dual-mobility sockets in achieving implant stability in primary hip replacement is already well established. However, stability cannot always be achieved, especially when dealing with more difficult indications. At our department, 104 dual-mobility sockets (92 uncemented and 12 cemented) were implanted for primary total hip arthroplasty in 97 patients between 2009 and 2013. Indications for hip arthroplasty included primary and secondary coxarthrosis, acetabular and subcapital fractures, avascular necrosis, tumor surgery and metastatic fractures. Although no loosenings were observed, 2 dislocations and 1 infection occurred shortly after surgery. In this challenging group of patients no fixation problems or intraprosthetic dislocations have been observed. The design therefore seems to be a valid alternative to constrained implants, especially in high-risk cases, although dislocation cannot be prevented at all times. Although the findings are very promising, long-term survival studies are mandatory to evaluate intraprosthetic stability and fixation longevity of dual-mobility sockets

    Current Trends in Improving of Artificial Joints Design and Technologies for Their Arthroplasty

    Get PDF
    There is a global tendency to rejuvenate joint diseases, and serious diseases such as arthrosis and arthritis develop in 90% of people over 55 years of age. They are accompanied by degradation of cartilage, joint deformities and persistent pain, which leads to limited mobility and a significant deterioration in the quality of life of patients. For the treatment of these diseases in the late stages, depending on the indications, various methods are used, the most radical of which are methods of joint arthroplasty and, in particular, total arthroplasty. Currently, total arthroplasty is one of the most effective and high-quality surgical operations at the relevant medical indications. However, complications may also arise after it, leading, inter alia, to the need for repeated surgical intervention. In order to minimize the likelihood of complications, the artificial joints used in total arthroplasty and the technology of their fabrication are constantly being improved, which leads to the emergence of new designs and methods for their integration with living tissues. At the same time, at the moment, the improvement of traditional designs and production technologies has almost reached the top of their art, and their further improvements can be insignificantly or are associated with the use of the most up-to-day technologies, allowing for friction couples with low tribological properties to provide for them high ones, for example, gradient increase hardness in the couple titanium alloy on titanium alloy. This paper presents the current state of traditional technical means and technologies for joint arthroplasty. The main attention is paid to the analysis of the latest technologies in the field of joint arthroplasty, such as osseointegration of artificial joints, the improvement of materials with the property of osteoimmunomodulation, the improvement of joint arthroplasty technologies based on the modeling of dynamic osteosynthesis, as well as the identification of possible unconventional designs of artificial joints that contribute to these technologies, predictive assessment of areas for technologies improvement.DFG, 414044773, Open Access Publizieren 2019 - 2020 / Technische Universität Berli
    • …
    corecore