90,668 research outputs found

    Development and application of a bioassay for follicle-stimulating hormone : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Physiology at Massey University

    Get PDF
    Follicle-stimulating hormone (FSH) is involved in the regulation and maintenance of vital reproductive processes, such as gametogenesis, follicular development and ovulation. Produced in the anterior pituitary, FSH is a glycoprotein hormone that exists as a family of isohormones. Follicle-stimulating hormone concentrations have traditionally been measured by radioimmunoassay (RIA). However, results generated using RIA are a determination of the immunological activity of FSH. The potential of FSH to generate a biological response cannot be measured by RIA. Therefore, the identification of physiologically significant differences in the activity of these isoforms requires the use of assay systems that can differentiate between the biological activity of the FSH isoforms. Commonly used assays for measuring the biological activity of FSH are based on the measurement of aromatase activity in cultured rat Sertoli cells following stimulation with FSH. However, these assays have an inherently high ethical cost involved due to the use of primary tissue culture. In addition, the variation in these assays associated with differences between animals is difficult to eliminate. Recently a bioassay for human FSH has been described based on FSH stimulation of cyclic AMP production by a Chinese hamster ovary (CHO) cell line stably expressing the human FSH receptor (FSH-R). The purpose of this study was to evaluate the potential usefulness of this CHO FSH-R cell line expressing the human receptor for FSH to be used as a bioassay to measure the biological activity of ovine FSH. The receptor cell line bioassay described in this study is based on the ability of FSH to stimulate cAMP production by cultured CHO FSH-R cells. Optimisation of the culture system to enable the bioactivity of ovine FSH to be measured by bioassay was undertaken. This involved optimising the density of cultured cells, the time in culture and time exposed to FSH and the most suitable dose range for FSH. The influence of matrix effects, such as those exerted by serum was also investigated. The specificity of the assay towards FSH was also determined as was the sensitivity, accuracy and precision of the assay. No stimulation of cAMP production was seen in CHO FSH-R cells following treatment with α-FSH, β-FSH, LH, TSH, GH, prolactin or vasopressin at concentrations up to 10 μg/ml. Although the methodology used differed slightly depending on the presence or absence of serum, all assayed were performed using the following methods and materials. Freshly thawed FSH-R cells were bulked up in culture, and aliquots of 1 x 105 to 5 x 105 cells/well dispensed into 48 well culture dishes and incubated overnight at 37°C. The assay culture media was then replaced with 0.25 ml fresh media (α-MEM + 0.1% BSA + 0.25 mM 3-isobutyl-1-methyl-xanthine) containing varying doses of NIH-FSH-RP2 (RP2) FSH preparations or FSH containing samples, and the cells incubated for 4 hours at 37°C. The assay culture media was then removed and stored frozen at -20°C until assayed for cyclic adenosine monophosphate (cAMP) by RIA. Once optimal assay conditions were determined, the CHO FSH-R cell bioassay was used to measure FSH concentrations in ovine serum, pituitary extracts and medium from cultures of ovine pituitary cells. It was found that the concentrations of FSH in serum from intact sheep was close to the detection limit of the assay. Thus, while FSH concentrations could be measured in serum from some sheep, other animals had concentrations that were too low to be accurately measured by the bioassay in its present form. The assay was, however, well suited to measuring FSH concentrations in serum from sheep that had elevated concentrations of FSH. In one study, FSH concentrations measured by the bioassay were compared to those measured by RIA in sheep that had been ovariectomised and then hypophysectomised. It was found that the profile of FSH concentrations following hypophysectomy was similar whether measured by RIA or by bioassay (R2=0.7513), though absolute concentrations sometimes differed. This suggested that the immunoassay and bioassay were not always measuring the same characteristics of FSH. The assay was also used to measure FSH concentrations in samples of ovine hypophyseal venous blood. However, the results obtained for these samples indicated a poor correlation between FSH concentrations obtained by bioassay and RIA. Levels of bioactive FSH in hypophyseal venous blood fluctuated markedly and were up to 10-fold higher than the associated RIA concentrations. The CHO-cell bioassay was also found to be very suitable for measuring pituitary concentrations of FSH. In one study, pituitary extracts underwent chromatography and the separated isoforms of FSH were analysed by bioassay and RIA. Again, there was excellent correlation (R2=0.9328) between the concentrations of FSH measured both assay types. However, some differences were apparent suggesting a discrepancy in the biological and immunological characteristics of different FSH isoforms. The bioassay was also used to measure FSH concentrations in media from pituitary cells in tissue culture where serially diluted samples displayed good parallelism with the RP2 FSH standard curve. Results of this study demonstrate that the CHO FSH-R cell bioassay is suitable for measuring the biological activity of ovine FSH in a variety of biological fluids. The use of a permanent cell line eliminates the high ethical cost associated with primary tissue culture that other bioassay systems have. The inherent variation associated with culture systems utilising tissue from different sources is also avoided. The sensitivity of the bioassay is suitable for measuring FSH in surgically altered sheep or hypophyseal blood concentrations where FSH levels are generally higher than those in the peripheral circulation. In addition to blood samples, the bioassay is also excellent for monitoring FSH activity in pituitary extracts and in media from tissue culture. However, the sensitivity of the bioassay currently does not always allow measurement of bioactive FSH concentrations in serum samples with low FSH levels. In summary, the CHO FSH-R cell bioassay described in this study offers a useful alternative to RIA and other bioassays for monitoring the biological activity of ovine FSH and its isoforms in various biological fluids. It is concluded that this convenient and robust bioassay may have considerable application in future investigations of ovine FSH bioactivity

    Paper-based chromatic toxicity bioassay by analysis of bacterial ferricyanide reduction

    Get PDF
    Water quality assessment requires a continuous and strict analysis of samples to guarantee compliance with established standards. Nowadays, the increasing number of pollutants and their synergistic effects lead to the development general toxicity bioassays capable to analyse water pollution as a whole. Current general toxicity methods, e.g. Microtox®, rely on long operation protocols, the use of complex and expensive instrumentation and sample pre-treatment, which should be transported to the laboratory for analysis. These requirements delay sample analysis and hence, the response to avoid an environmental catastrophe. In an attempt to solve it, a fast (15 min) and low-cost toxicity bioassay based on the chromatic changes associated to bacterial ferricyanide reduction is here presented. E. coli cells (used as model bacteria) were stably trapped on low-cost paper matrices (cellulose-based paper discs, PDs) and remained viable for long times (1 month at -20 °C). Apart from bacterial carrier, paper matrices also acted as a fluidic element, allowing fluid management without the need of external pumps. Bioassay evaluation was performed using copper as model toxic agent. Chromatic changes associated to bacterial ferricyanide reduction were determined by three different transduction methods, i.e. (i) optical reflectometry (as reference method), (ii) image analysis and (iii) visual inspection. In all cases, bioassay results (in terms of half maximal effective concentrations, EC50) were in agreement with already reported data, confirming the good performance of the bioassay. The validation of the bioassay was performed by analysis of real samples from natural sources, which were analysed and compared with a reference method (i.e. Microtox). Obtained results showed agreement for about 70% of toxic samples and 80% of non-toxic samples, which may validate the use of this simple and quick protocol in the determination of general toxicity. The minimum instrumentation requirements and the simplicity of the bioassay open the possibility of in-situ water toxicity assessment with a fast and low-cost protocolPostprint (author's final draft

    Combining Plant Pathogenic Fungi and the Leaf-Mining Fly, Hydrellia pakistanae, Increases Damage to Hydrilla

    Get PDF
    Four fungal species, F71PJ Acremonium sp., F531 Cylindrocarpon sp., F542, Botrytis sp., and F964 Fusarium culmorum [Wm. G. Sm.] Sacc. were recovered from hydrilla [ Hydrilla verticillata (L. f.) Royle] shoots or from soil and water surrounding hydrilla growing in ponds and lakes in Florida and shown to be capable of killing hydrilla in a bioassay. The isolates were tested singly and in combination with the leaf-mining fly, Hydrellia pakistanae (Diptera: Ephydridae), for their capability to kill or severely damage hydrilla in a bioassay

    Microbial detoxification of deoxynivalenol (DON), assessed via a Lemna minor L. bioassay, through biotransformation to 3-epi-DON and 3-epi-DOM-1

    Get PDF
    Mycotoxins are toxic metabolites produced by fungi. To mitigate mycotoxins in food or feed, biotransformation is an emerging technology in which microorganisms degrade toxins into non-toxic metabolites. To monitor deoxynivalenol (DON) biotransformation, analytical tools such as ELISA and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) are typically used. However, these techniques do not give a decisive answer about the remaining toxicity of possible biotransformation products. Hence, a bioassay using Lemna minor L. was developed. A dose-response analysis revealed significant inhibition in the growth of L. minor exposed to DON concentrations of 0.25 mg/L and higher. Concentrations above 1 mg/L were lethal for the plant. This bioassay is far more sensitive than previously described systems. The bioassay was implemented to screen microbial enrichment cultures, originating from rumen fluid, soil, digestate and activated sludge, on their biotransformation and detoxification capability of DON. The enrichment cultures originating from soil and activated sludge were capable of detoxifying and degrading 5 and 50 mg/L DON. In addition, the metabolites 3-epi-DON and the epimer of de-epoxy-DON (3-epi-DOM-1) were found as biotransformation products of both consortia. Our work provides a new valuable tool to screen microbial cultures for their detoxification capacity

    Bioassay Analysis Using R

    Get PDF
    We describe an add-on package for the language and environment R which allows simultaneous fitting of several non-linear regression models. The focus is on analysis of dose response curves, but the functionality is applicable to arbitrary non-linear regression models. Features of the package is illustrated in examples.

    Thermal Tolerances of Interior Alaskan Arctic Grayling (Thymallus arcticus)

    Get PDF
    The work upon which this report is based was supported in part by funds (Project A-041-ALAS) provided by the United States Department of the Interior, Office of Water Resources Research, as authorized under the Water Resources Act of 1964, as amended

    Evidence of the indirect hormonal activity of prohormones using liver S9 metabolic bioactivation and an androgen bioassay

    Get PDF
    Prohormones such as dehydroepiandrosterone (DHEA) are steroid precursors that do not show hormonal activity by themselves. Abuse of these prohormones in cattle fattening is hard to prove because of strong in vivo metabolism and the difficulty to detect metabolites which are not significantly above endogenous levels. The aim of the present work was to develop an in vitro assay capable of detecting the indirect hormonal activity of prohormones that might be present in feed supplements and injection preparations. Sample extracts were incubated with a bovine liver S9 fraction in order to mimic the in vivo metabolic activation. Subsequently incubated extracts were exposed to a highly androgen-specific yeast bioassay to detect hormonal activity. Metabolic activation of DHEA, 4-androstene-3,17-dione (4-adione) and 5-androstene-3,17-diol (5-adiol) resulted in an increased androgenic activity caused by the formation of the active androgen 17ß-testosterone (17ß-T), as shown by ultra-performance liquid chromatography and time-of-flight mass spectrometry with accurate mass measurement. The developed in vitro system successfully mimics the hydroxysteroid dehydrogenase (HSD)- and cytochrome P450-mediated in vivo metabolic transitions, thus allowing assessment of both bioactivity and chemical identification without the use of animal experiments. Screening of unknown supplement samples claimed to contain DHEA resulted in successful bioactivation and positive screening results according to the androgen yeast biosenso
    corecore