1,237 research outputs found
GPS多天线数据采集与控制系统
Author name used in this publication: 孙永荣, Sun YongrongAuthor name used in this publication: 丁晓莉Author name used in this publication: 陈武Author name used in this publication: 刘建业Title in Traditional Chinese: GPS多天線數據采集與控制系統Journal title in Traditional Chinese: 數據采集與處理2002-2003 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
GPS软件接收机并行处理的实现
Author name used in this publication: 苗剑峰Author name used in this publication: 孙永荣Author name used in this publication: 陈武Author name used in this publication: 刘建业Author name used in this publication: 胡丛伟Title in Traditional Chinese: GPS軟件接收機并行處理的實現Journal title in Traditional Chinese: 應用科學學報2008-2009 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
新一代多天线GPS系统研制
Author name used in this publication: 丁晓利, DING Xiao-liAuthor name used in this publication: 黄丁发Author name used in this publication: YIN Jian-huaAuthor name used in this publication: 陈永奇Author name used in this publication: 孙永荣Author name used in this publication: 杨育文Title in Traditional Chinese: 新一代多天線GPS系統研製Journal title in Traditional Chinese: 測繪通報2003-2004 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe
Proximal Analysis and the Minimal Time Function of a Class of Semilinear Control Systems
The minimal time function of a class of semilinear control systems is considered in Banach spaces, with the target set being a closed ball. It is shown that the minimal time functions of the Yosida approximation equations converge to the minimal time function of the semilinear control system. Complete characterization is established for the subdifferential of the minimal time function satisfying the Hamilton–Jacobi–Bellman equation. These results extend the theory of finite dimensional linear control systems to infinite dimensional semilinear control systems
Variable dose interplay effects across radiosurgical apparatus in treating multiple brain metastases
PURPOSE: Normal brain tissue doses have been shown to be strongly apparatus dependent for multi-target stereotactic radiosurgery. In this study, we investigated whether inter-target dose interplay effects across contemporary radiosurgical treatment platforms are responsible for such an observation. METHODS: For the study, subsets ([Formula: see text] and 12) of a total of 12 targets were planned at six institutions. Treatment platforms included the (1) Gamma Knife Perfexion (PFX), (2) CyberKnife, (3) Novalis linear accelerator equipped with a 3.0-mm multi-leaf collimator (MLC), and the (4) Varian Truebeam flattening-filter-free (FFF) linear accelerator also equipped with a 2.5 mm MLC. Identical dose–volume constraints for the targets and critical structures were applied for each apparatus. All treatment plans were developed at individual centers, and the results were centrally analyzed. RESULTS: We found that dose–volume constraints were satisfied by each apparatus with some differences noted in certain structures such as the lens. The peripheral normal brain tissue doses were lowest for the PFX and highest for TrueBeam FFF and CyberKnife treatment plans. Comparing the volumes of normal brain receiving 12 Gy, TrueBeam FFF, Novalis, and CyberKnife were 180–290 % higher than PFX. The mean volume of normal brain-per target receiving 4-Gy increased by approximately 3.0 cc per target for TrueBeam, 2.7 cc per target for CyberKnife, 2.0 cc per target for Novalis, and 0.82 cc per target for PFX. The beam-on time was shortest with the TrueBeam FFF (e.g., 6–9 min at a machine output rate of 1,200 MU/min) and longest for the PFX (e.g., 50–150 mins at a machine output rate of 350 cGy/min). CONCLUSION: The volumes of normal brain receiving 4 and 12 Gy were higher, and increased more swiftly per target, for Linac-based SRS platforms than for PFX. Treatment times were shortest with TrueBeam FFF
Simple Metals at High Pressure
In this lecture we review high-pressure phase transition sequences exhibited
by simple elements, looking at the examples of the main group I, II, IV, V, and
VI elements. General trends are established by analyzing the changes in
coordination number on compression. Experimentally found phase transitions and
crystal structures are discussed with a brief description of the present
theoretical picture.Comment: 22 pages, 4 figures, lecture notes for the lecture given at the Erice
course on High-Pressure Crystallography in June 2009, Sicily, Ital
Serum amyloid A primes microglia for ATP-dependent interleukin-1\u3b2 release
Acute-phase response is a systemic reaction to environmental/inflammatory insults and involves production of acute-phase proteins, including serum amyloid A (SAA). Interleukin-1\u3b2 (IL-1\u3b2), a master regulator of neuroinflammation produced by activated inflammatory cells of the myeloid lineage, in particular microglia, plays a key role in the pathogenesis of acute and chronic diseases of the peripheral nervous system and CNS. IL-1\u3b2 release is promoted by ATP acting at the purinergic P2X7 receptor (P2X7R) in cells primed with toll-like receptor (TLR) ligands
Investigations on DNA damage and frequency of micronuclei in occupational exposure to electromagnetic fields (EMFs) emitted from video display terminals (VDTs)
The potential effect of electromagnetic fields (EMFs) emitted from video display terminals (VDTs) to elicit biological response is a major concern for the public. The software professionals are subjected to cumulative EMFs in their occupational environments. This study was undertaken to evaluate DNA damage and incidences of micronuclei in such professionals. To the best of our knowledge, the present study is the first attempt to carry out cytogenetic investigations on assessing bioeffects in personal computer users. The study subjects (n = 138) included software professionals using VDTs for more than 2 years with age, gender, socioeconomic status matched controls (n = 151). DNA damage and frequency of micronuclei were evaluated using alkaline comet assay and cytochalasin blocked micronucleus assay respectively. Overall DNA damage and incidence of micronuclei showed no significant differences between the exposed and control subjects. With exposure characteristics, such as total duration (years) and frequency of use (minutes/day) sub-groups were assessed for such parameters. Although cumulative frequency of use showed no significant changes in the DNA integrity of the classified sub-groups, the long-term users (> 10 years) showed higher induction of DNA damage and increased frequency of micronuclei and micro nucleated cells
The d subunit plays a central role in human vacuolar H+-ATPases
The multi-subunit vacuolar-type H+-ATPase consists of a V1 domain (A–H subunits) catalyzing ATP hydrolysis and a V0 domain (a, c, c′, c″, d, e) responsible for H+ translocation. The mammalian V0 d subunit is one of the least-well characterized, and its function and position within the pump are still unclear. It has two different forms encoded by separate genes, d1 being ubiquitous while d2 is predominantly expressed at the cell surface in kidney and osteoclast. To determine whether it forms part of the pump’s central stalk as suggested by bacterial A-ATPase studies, or is peripheral as hypothesized from a yeast model, we investigated both human d subunit isoforms. In silico structural modelling demonstrated that human d1 and d2 are structural orthologues of bacterial subunit C, despite poor sequence identity. Expression studies of d1 and d2 showed that each can pull down the central stalk’s D and F subunits from human kidney membrane, and in vitro studies using D and F further showed that the interactions between these proteins and the d subunit is direct. These data indicate that the d subunit in man is centrally located within the pump and is thus important in its rotary mechanism
Wettability of amorphous and nanocrystalline Fe78B13Si9 substrates by molten Sn and Bi
The wettability of amorphous and annealing-induced nanocrystalline Fe78B13Si9 ribbons by molten Sn and Bi at 600 K was measured using an improved sessile drop method. The results demonstrate that the structural relaxation and crystallization in the amorphous substrates do not substantially change the wettability with molten Bi because of their invariable physical interaction, but remarkably deteriorate the wettability and interfacial bonding with molten Sn as a result of changing a chemical interaction to a physical one for the atoms at the interface
- …