827 research outputs found

    Student engagement and learning outcomes:an empirical study applying a four-dimensional framework

    Get PDF
    Introduction: This study applies Reeve’s four-dimensional student engagement framework to a medical education context to elucidate the relationship between behavioral, emotional, cognitive, and agentic engagement and learning outcomes. Meanwhile, we categorize learning outcomes in knowledge and skills, and added taxonomies to the cognitive education objectives for the knowledge part, including memorization, comprehension, and application. Methods: We used the China Medical Student Survey to investigate student engagement, and combined it with the Clinical Medicine Proficiency Test for Medical Schools results as a standardized measurement of learning outcomes. We performed multivariate regression analyses to delve into the effectiveness of different types of student engagement. Moreover, we evaluated the moderating roles of gender and the National College Entrance Examination (NCEE) within the relationships between student engagement and learning outcomes. Results: We observed that emotional engagement is most effective in promoting learning outcomes in basic medical knowledge and basic clinical skills. Emotional engagement and cognitive engagement could effectively contribute to learning outcomes in all three aspects of basic medical knowledge. In contrast, behavioral and agentic engagement showed negative effects on learning outcomes. Besides, we found that the results of the NCEE played a positive moderating role. Conclusion: This study provides robust evidence for the effectiveness of emotional engagement and cognitive engagement in promoting learning outcomes. Whereas behavioral and agentic engagement may not be good predictors of learning outcomes in macro-level general competence tests. We suggest a combined effort by students and institutions to promote student engagement and bridge the distance between general competency tests and daily learning activities.</p

    A novel prognostic 7-methylguanosine signature reflects immune microenvironment and alternative splicing in glioma based on multi-omics analysis

    Get PDF
    Glioma is the most common type of central nervous system tumor with increasing incidence. 7-methylguanosine (m7G) is one of the diverse RNA modifications that is known to regulate RNA metabolism and its dysregulation was associated with various cancers. However, the expression pattern of m7G regulators and their roles in regulating tumor immune microenvironments (TIMEs) as well as alternative splicing events (ASEs) in glioma has not been reported. In this study, we showed that m7G regulators displayed a close correlation with each other and most of them were differentially expressed between normal and glioma tissues. Two m7G signatures were then constructed to predict the overall survival of both GBM and LGG patients with moderate predictive performance. The risk score calculated from the regression coefficient and expression level of signature genes was proved to be an independent prognostic factor for patients with LGG, thus, a nomogram was established on the risk score and other independent clinical parameters to predict the survival probability of LGG patients. We also investigated the correlation of m7G signatures with TIMEs in terms of immune scores, expression levels of HLA and immune checkpoint genes, immune cell composition, and immune-related functions. While exploring the correlation between signature genes and the ASEs in glioma, we found that EIF4E1B was a key regulator and might play dual roles depending on glioma grade. By incorporating spatial transcriptomic data, we found a cluster of cells featured by high expression of PTN exhibited the highest m7G score and may communicate with adjacent cancer cells via SPP1 and PTN signaling pathways. In conclusion, our work brought novel insights into the roles of m7G modification in TIMEs and ASEs in glioma, suggesting that evaluation of m7G in glioma could predict prognosis. Moreover, our data suggested that blocking SPP1 and PTN pathways might be a strategy for combating glioma

    Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients

    Get PDF
    OBJECTIVES: To describe a new approach for the application of polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws. METHODS: Between June 2010 and February 2013, 43 patients with degenerative spinal disease and osteoporosis (T-scor

    Spin Coherence and Spin Relaxation in Hybrid Organic-Inorganic Lead and Mixed Lead-Tin Perovskites

    Full text link
    Metal halide perovskites make up a promising class of materials for semiconductor spintronics. Here we report a systematic investigation of coherent spin precession, spin dephasing and spin relaxation of electrons and holes in two hybrid organic-inorganic perovskites MA0.3FA0.7PbI3 and MA0.3FA0.7Pb0.5Sn0.5I3 using time-resolved Faraday rotation spectroscopy. With applied in-plane magnetic fields, we observe robust Larmor spin precession of electrons and holes that persists for hundreds of picoseconds. The spin dephasing and relaxation processes are likely to be sensitive to the defect levels. Temperature-dependent measurements give further insights into the spin relaxation channels. The extracted electron Land\'e g-factors (3.75 and 4.36) are the biggest among the reported values in inorganic or hybrid perovskites. Both the electron and hole g-factors shift dramatically with temperature, which we propose to originate from thermal lattice vibration effects on the band structure. These results lay the foundation for further design and use of lead- and tin-based perovskites for spintronic applications

    A Less Intrusive Solution To Stablize VSC Transmission Against Highly Variable Grid Strength

    Get PDF
    A less-intrusive solution to stabilize a Voltage Source Converter (VSC) over an unknown grid strength is presented in this paper. The existence of equilibrium point is investigated as a prerequisite to stabilization. By partially imposing grid forming control, a simple auxiliary outer loop is proposed to exhaust the physical limit of power delivery in steady state and provide support to fault-ride-through operations over a wide range of grid strength. The proposed control can be used to upgrade a commissioned VSC with inner current loop intact; it also offers a non-intrusive solution to stabilize VSCs externally. The effectiveness of the proposed approach and schemes are verified by analysis in frequency domain and case studies in time domain including change of grid strength and fault-ride-through

    Clinical evaluation of a bone cement-injectable cannulated pedicle screw augmented with polymethylmethacrylate: 128 osteoporotic patients with 42 months of follow-up

    Get PDF
    OBJECTIVES: To evaluate the safety and efficacy of a novel bone cement-injectable cannulated pedicle screw augmented with polymethylmethacrylate in osteoporotic spinal surgery. METHODS: This study included 128 patients with osteoporosis (BMD T-score –3.2±1.9; range, –5.4 to –2.5) who underwent spinal decompression and instrumentation with a polymethylmethacrylate-augmented bone cement-injectable cannulated pedicle screw. Postoperative Visual Analogue Scale scores and the Oswestry Disability Index were compared with preoperative values. Postoperative plain radiographs and computed tomography (CT) scans were performed immediately after surgery; at 1, 3, 6, and 12 months; and annually thereafter. RESULTS: The mean follow-up time was 42.4±13.4 months (range, 23 to 71 months). A total of 418 polymethylmethacrylate-augmented bone cement-injectable cannulated pedicle screws were used. Cement extravasations were detected in 27 bone cement-injectable cannulated pedicle screws (6.46%), mainly in cases of vertebral fracture, without any clinical sequela. The postoperative low back and lower limb Visual Analogue Scale scores were significantly reduced compared with the preoperative scores (o0.01), and similar results were noted for the Oswestry Disability Index score (po0.01). No significant screw migration was noted at the final follow-up relative to immediately after surgery (po0.01). All cases achieved successful bone fusion, and no case required revision. No infection or blood clots occurred after surgery. CONCLUSIONS: The polymethylmethacrylate-augmented bone cement-injectable cannulated pedicle screw is safe and effective for use in osteoporotic patients who require spinal instrumentation
    • …
    corecore