1,034 research outputs found

    Characterising and Testing Deep UV LEDs for Use in Space Applications

    Full text link
    Deep ultraviolet (DUV) light sources are used to neutralise isolated test masses in highly sensitive space-based gravitational experiments. An example is the LISA Pathfinder charge management system, which uses low-pressure mercury lamps. A future gravitational-wave observatory such as eLISA will use UV light-emitting diodes (UV LEDs), which offer numerous advantages over traditional discharge lamps. Such devices have limited space heritage but are are now available from a number of commercial suppliers. Here we report on a test campaign that was carried out to quantify the general properties of three types of commercially available UV LEDs and demonstrate their suitability for use in space. Testing included general electrical and UV output measurements, spectral stability, pulsed performance, temperature dependence as well as thermal vacuum, radiation and vibration survivability

    The LISA PathFinder DMU and Radiation Monitor

    Get PDF
    The LISA PathFinder DMU (Data Management Unit) flight model was formally accepted by ESA and ASD on 11 February 2010, after all hardware and software tests had been successfully completed. The diagnostics items are scheduled to be delivered by the end of 2010. In this paper we review the requirements and performance of this instrumentation, specially focusing on the Radiation Monitor and the DMU, as well as the status of their programmed use during mission operations, on which work is ongoing at the time of writing.Comment: 11 pages, 7 figures, prepared for the Proceedings of the 8th International LISA Symposium, Classical and Quantum Gravit

    New LISA dynamics feedback control scheme: Common-mode isolation of test mass control and probes of test-mass acceleration

    Get PDF
    The Drag-Free and Attitude Control System is a central element of LISA technology, ensuring the very high dynamic stability of spacecraft and test masses required in order to reach the sensitivity that gravitational wave astronomy in space requires. Applying electrostatic forces on test-masses is unavoidable but should be restricted to the minimum necessary to keep the spacecraft-test masses system in place, while granting the optimal quality of test-mass free-fall. To realise this, we propose a new test-mass suspension scheme that applies forces and torques only in proportion to any differential test mass motion observed, and we demonstrate that the new scheme significantly mitigates the amount of suspension forces and torques needed to control the whole system. The mathematical method involved allows us to derive a new observable measuring the differential acceleration of test masses projected on the relevant sensitive axes, which will have important consequences for LISA data calibration, processing and analysis

    Robust synthesis of epoxy resin-filled microcapsules for application to self-healing materials

    Get PDF
    Mechanically and thermally robust microcapsules containing diglycidyl ether bisphenol A-based epoxy resin and a high-boiling-point organic solvent were synthesized in high yield using in situ polymerization of urea and formaldehyde in an oil-in-water emulsion. Microcapsules were characterized in terms of their size and size distribution, shell surface morphology and thermal resistance to the curing cycles of commercially used epoxy polymers. The size distribution of the capsules and characteristics such as shell thickness can be controlled by the specific parameters of microencapsulation, including concentrations of reagents, stirrer speed and sonication. Selected microcapsules, and separated core and shell materials, were analysed using thermogravimetric analysis and differential scanning calorimetry. It is demonstrated that capsules lose minimal 2.5 wt% at temperatures no higher than 120°C. These microcapsules can be applied to self-healing carbon fibre composite structural materials, with preliminary results showing promising performance

    Bovine and Porcine Somatotropin

    Get PDF
    Among the more recent biological tools being proposed and studied for dairy and swine management programs is somatotropin (growth hormone or GH). Advocates claim that somatotropin improves efficiency and thus decreases the cost of production in dairy cows and growing swine. With Food and Drug Administration (F&DA) approval of bovine somatotropin (SST) expected within the year in the United States and approval of porcine somatotropin (PST) being sought, food animal veterinarians need to be knowledgeable of somatotropin and must be prepared to advise clients on the use of the product as a management tool

    The Labour Government, the Treasury and the £6 pay policy of July 1975

    Get PDF
    The 1974-79 Labour Government was elected in a climate of opinion that was fiercely opposed to government intervention in the wage determination process, and was committed to the principles of free collective bargaining in its manifestoes. However, by December 1974 the Treasury was advocating a formal incomes policy, and by July 1975 the government had introduced a £6 flat rate pay norm. With reference to archival sources, the paper demonstrates that TUC and Labour Party opposition to incomes policy was reconciled with the Treasury's advocacy by limiting the Bank of England‟s intervention in the foreign exchange market when sterling came under pressure. This both helped to achieve the Treasury's objective of improving the competitiveness of British industry, and acted as a catalyst for the introduction of incomes policy because the slide could be attributed to a lack of market confidence in British counter-inflation policy

    Slip behavior in liquid films on surfaces of patterned wettability: Comparison between continuum and molecular dynamics simulations

    Get PDF
    We investigate the behavior of the slip length in Newtonian liquids subject to planar shear bounded by substrates with mixed boundary conditions. The upper wall, consisting of a homogenous surface of finite or vanishing slip, moves at a constant speed parallel to a lower stationary wall, whose surface is patterned with an array of stripes representing alternating regions of no-shear and finite or no-slip. Velocity fields and effective slip lengths are computed both from molecular dynamics (MD) simulations and solution of the Stokes equation for flow configurations either parallel or perpendicular to the stripes. Excellent agreement between the hydrodynamic and MD results is obtained when the normalized width of the slip regions, a/σ≳O(10)a/\sigma \gtrsim {\cal O}(10), where σ\sigma is the (fluid) molecular diameter characterizing the Lennard-Jones interaction. In this regime, the effective slip length increases monotonically with a/σa/\sigma to a saturation value. For a/σ≲O(10)a/\sigma \lesssim {\cal O}(10) and transverse flow configurations, the non-uniform interaction potential at the lower wall constitutes a rough surface whose molecular scale corrugations strongly reduce the effective slip length below the hydrodynamic results. The translational symmetry for longitudinal flow eliminates the influence of molecular scale roughness; however, the reduced molecular ordering above the wetting regions of finite slip for small values of a/σa/\sigma increases the value of the effective slip length far above the hydrodynamic predictions. The strong inverse correlation between the effective slip length and the liquid structure factor representative of the first fluid layer near the patterned wall illustrates the influence of molecular ordering effects on slip in non-inertial flows.Comment: 12 pages, 10 figures Web reference added for animations: http://www.egr.msu.edu/~priezjev/bubble/bubble.htm

    Limits of 'patient-centredness'; valuing contextually specific communication patterns

    Get PDF
    Context Globally, doctor–patient communication is becoming synonymous with high-quality health care in the 21st century. However, what is meant by ‘good communication’ and whether there is consensus internationally remain unclear. Objectives Here, we characterise understandings of ‘good communication’ in future doctors from medical schools in three contextually contrasting continents. Given locally specific socio-cultural influences, we hypothesised that there would be a lack of global consensus on what constitutes ‘good communication’. Methods A standardised two-phase methodology was applied in turn to each of three medical schools in the UK, Egypt and India (n = 107 subjects), respectively, in which students were asked: ‘What is good communication?’ Phase I involved exploratory focus groups to define preliminary themes (mean number of participants per site: 17). Phase II involved thematic confirmation and expansion in one-to-one semi-structured interviews (mean number of participants per site: 18; mean hours of dialogue captured per site: 55). Findings were triangulated and analysed using grounded theory. Results The overarching theme that emerged from medical students was that ‘good communication’ requires adherence to certain ‘rules of communication’. A shared rule that doctors must communicate effectively despite perceived disempowerment emerged across all sites. However, contradictory culturally specific rules about communication were identified in relation to three major domains: family; gender, and emotional expression. Egyptian students perceived emotional aspects of Western doctors’ communication strikingly negatively, viewing these doctors as problematically cold and unresponsive. Conclusions Contradictory perceptions of ‘good communication’ in future doctors are found cross-continentally and may contribute to prevalent cultural misunderstandings in medicine. The lack of global consensus on what defines good communication challenges prescriptively taught Western ‘patient-centredness’ and questions assumptions about international transferability. Health care professionals must be educated openly about flexible, context-specific communication patterns so that they can avoid cultural incompetence and tailor behaviours in ways that optimise therapeutic outcomes wherever they work around the globe

    LISA and LISA PathFinder, the endeavour to detect low frequency GWs

    Full text link
    This is a review about LISA and its technology demonstrator, LISA PathFinder. We first describe the conceptual problems which need to be overcome in order to set up a working interferometric detector of low frequency Gravitational Waves (GW), then summarise the solutions to them as currently conceived by the LISA mission team. This will show that some of these solutions require new technological abilities which are still under development, and which need proper test before being fully implemented. LISA PathFinder (LPF) is the the testbed for such technologies. The final part of the paper will address the ideas and concepts behind the PathFinder as well as their impact on LISA.Comment: 25 pages, 21 figures, presented at the Spanish Relativity Meeting, Mallorca September 2006. Will be published in Journal of Physics: Conference Series, IOP. To be published in Journal of Physics: Conference Series, IO

    Charge Management for Gravitational Wave Observatories using UV LEDs

    Full text link
    Accumulation of electrical charge on the end mirrors of gravitational wave observatories, such as the space-based LISA mission and ground-based LIGO detectors, can become a source of noise limiting the sensitivity of such detectors through electronic couplings to nearby surfaces. Torsion balances provide an ideal means for testing gravitational wave technologies due to their high sensitivity to small forces. Our torsion pendulum apparatus consists of a movable Au-coated Cu plate brought near a Au-coated Si plate pendulum suspended from a non-conducting quartz fiber. A UV LED located near the pendulum photoejects electrons from the surface, and a UV LED driven electron gun directs photoelectrons towards the pendulum surface. We have demonstrated both charging and discharging of the pendulum with equivalent charging rates of ∼\sim105e/s10^5 e/\mathrm{s}, as well as spectral measurements of the pendulum charge resulting in a white noise level equivalent to 3×105e/Hz3\times10^5 e/\sqrt{Hz}.Comment: 5 pages, submitted to PR
    • …
    corecore