17 research outputs found

    Wall crane

    Get PDF
    Tato bakalářská práce se zabývá konstrukčním návrhem nástěnného jeřábu. Cílem je navržení hlavní nosné konstrukce a hlavních rozměrů. Jedná se o navržení konstrukce jeřábu včetně zpracování důležitých pevnostních výpočtů. Jeřáb umožňuje natáčení, vyložení břemene 3300 mm o maximální hmotnosti 800 kg. K návrhu patří také volba vhodného kladkostroje.This bachelor thesis deals with a construction proposal of wall crane. The aim is to suggest main load-bearing constructions and the key dimensions. It describes suggestion of crane including processing of important strength calculations. The crane enables rotation, unloading arm 3300 mm of maximum weight 800 kg. This suggestion also includes the choice of the proper hoist.

    Silo for milled mineral salt

    Get PDF
    Tato diplomová práce se zabývá návrhem zásobníku pro mletou kamennou sůl. Jsou zde popsány druhy zásobníků, dále je proveden rozbor konstrukce a volby typu zásobníku, pevnostní výpočet a návrh rozměrů. Dále jsou zde popsány aktivní a pasivní stavy napjatosti materiálu v zásobníku. Práce se zabývá vznikem vzpěrné klenby při vyprazdňování a popisem prvků napomáhajících toku materiálu. Je zde také popsána specifičnost materiál s ohledem na konstrukci.This diploma thesis describes the design of silo for milled mineral salt and. There are described the types of silos and there is also analysis of type choise and silo construction, dimension design and silo strenght calculation. Further there are described active and passive stress state of the material in the silo. The thesis deals the possibility of emptying the vaults and there is describtion of active and passive elements, that condustive to flow of materiál. It also describes the specificity of the material considering the structure of silo.

    Protokol o testování plastického scintilátoru v dobře popsaných neutronových polích

    Get PDF
    Získané výsledky ukazují na schopnost plastického scintilátoru oddělovat fotonovou a neutronovou složku záření a dále schopnost vyvinutého softwaru provést dekonvoluci naměřených dat do energetického spektra. I přes znatelně horší energetické rozlišení lze říci, že zařízení a SW pro zpracování zpracuje data z plastického detektoru EJ 299-33A velmi dobře. Zařízení lze jako celek velmi dobře používat pro detekci neutronů i s uvedeným, velmi odolným a levným scintilátorem.Získané výsledky ukazují na schopnost plastického scintilátoru oddělovat fotonovou a neutronovou složku záření a dále schopnost vyvinutého softwaru provést dekonvoluci naměřených dat do energetického spektra. I přes znatelně horší energetické rozlišení lze říci, že zařízení a SW pro zpracování zpracuje data z plastického detektoru EJ 299-33A velmi dobře. Zařízení lze jako celek velmi dobře používat pro detekci neutronů i s uvedeným, velmi odolným a levným scintilátorem.This result shows the ability of plastic scintillator discriminate between photons and neutrons and the ability of developed software unfold measured data to energetic spectrum. The energetic resolution is worst than in the case of clasic scintillators like NE-213 or stilbene. Otherwise plastic scintillator is cheaper and more durable

    Characterization of the Graphite Pile as a Source of Thermal Neutrons

    Get PDF
    The absorption cross sections of low energy neutrons obey 1/v law for most materials. Therefore, the detection efficiency of a particular detector increase with decreasing neutron energy. Consequently, most of neutron measuring instruments consist of the detector of thermal neutrons which is located inside of the polyethylene moderator. Development of such instruments requires testing and response calibrations in the field of thermal neutrons. Availability of thermal neutron beams on nuclear reactors is limited and access to them is rather complicated, so it is more convenient to moderate neutrons from the radionuclide neutron sources. Since radionuclide neutron sources are producing fast neutrons it is necessary to use an appropriate moderator material like heavy water or graphite to thermalize neutrons from the source and to avoid thermal neutron capture in the same time.The absorption cross sections of low energy neutrons obey 1/v law for most materials. Therefore, the detection efficiency of a particular detector increase with decreasing neutron energy. Consequently, most of neutron measuring instruments consist of the detector of thermal neutrons which is located inside of the polyethylene moderator. Development of such instruments requires testing and response calibrations in the field of thermal neutrons. Availability of thermal neutron beams on nuclear reactors is limited and access to them is rather complicated, so it is more convenient to moderate neutrons from the radionuclide neutron sources. Since radionuclide neutron sources are producing fast neutrons it is necessary to use an appropriate moderator material like heavy water or graphite to thermalize neutrons from the source and to avoid thermal neutron capture in the same time

    Detection of mixed fields of neutron and photon radiation using 3He and new scintillation materials

    Get PDF
    The poster includes experimental measurements with 3He and the latest scintillation materials EJ-299-33 in fields of neutron and photon radiation using modern electronics which we designed. Electronic part of the measuring system is built on recently developed AD converter with very high sampling frequency (1 GHz). In the theoretical part, the Monte Carlo simulations of response characteristics of the measured scintillation materials are presented.Poster obsahuje experimentální měření za požití He-3 a nejnovějšího scintilačního materiálu EJ-299-33 v polích neutronů a fotonů. Elektronická část je postavena na základě velmi rychlých AD převodnků (1 GHz). V teoretické části je popsána Monte Carlo simulace odezvové matice použitých detektorů.The poster includes experimental measurements with 3He and the latest scintillation materials EJ-299-33 in fields of neutron and photon radiation using modern electronics which we designed. Electronic part of the measuring system is built on recently developed AD converter with very high sampling frequency (1 GHz). In the theoretical part, the Monte Carlo simulations of response characteristics of the measured scintillation materials are presented

    Digitalized two parametric system for gamma/neutron spectrometry

    Get PDF
    Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included.Článek popisuje spektrometr pro měření ve směsných polích gama/neutrony. Analogový signál z detektoru je vzorkován AD převodníky pracujícími na frekvenci 1 GHz. Předzpracování signálu probíhá v FPGA a tím je zajištěna vysoká propustnost systému bez mrtvé doby. Spektrometr byl testován v Centru výzkumu Řež na reaktoru LR-0.Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included

    Protokol o testování plastického detektoru v poli radionuklidu Cf-252

    Get PDF
    Získané výsledky ukazují na schopnost plastického scintilátoru oddělovat fotonovou a neutronovou složku záření. Spodní hranice diskriminace je pod 1 MeV a v porovnání se zkušenostmi se scintilátorem stilben lze předpokládat, že dekonvoluce energetického spektra bude možná v energetickém intervalu nad 2 MeV.Získané výsledky ukazují na schopnost plastického scintilátoru oddělovat fotonovou a neutronovou složku záření. Spodní hranice diskriminace je pod 1 MeV a v porovnání se zkušenostmi se scintilátorem stilben lze předpokládat, že dekonvoluce energetického spektra bude možná v energetickém intervalu nad 2 MeV.The results indicate the ability of the plastic scintillator separate neutron and photon radiation component. The lower boundary of discrimination is below 1 MeV and compared with experience with stilbene scintillator can be assumed that the energy spectrum deconvolution will be possible in the energy range above 2 MeV

    Variable Bit Width of the Integer in LLVM Platform

    No full text
    Tato práce se zabývá úpravou kompilační platformy LLVM/Clang tak, aby podporovala libovolnou bitovou šířku u datového typu integerThis Bachelor thesis describes changes on compilation platform LLVM/Clang for support variable bit width of integer data types.

    Nástroj pro oddělení fotonové a neutronové odezvy plastického scintilátoru

    No full text
    Plastický scintilační materiál je citlivý jak na neutronovou, tak i fotonovou složku záření. Pro další zpracování je nutné tyto složky oddělit. Kód je určený pro FPGA.Plastický scintilační materiál je citlivý jak na neutronovou, tak i fotonovou složku záření. Pro další zpracování je nutné tyto složky oddělit. Kód je určený pro FPGA.Plastic scintillators are sensitive both to gamma and neutron radiations. For the next processing these components have to be discriminated. This code is for FPGA

    Aplikace pro sběr a analýzu dat z dvouparametrického spektrometrického systému

    No full text
    Aplikace Dcapture slouží k průběžnému zachytávání a následnému zpracování dat z vyvíjeného dvouparametrického spektrometrického systému FD-11 ŠOHAJ. Dvouparematrický spektrometrický systém FD-11 ŠOHAJ vznikl jako výsledek projektu SPEKTRUM TAČR, je chráněn dvěma užitnými vzory a dokáže pracovat řádově o dva řády rychleji než dovadní spetrometry, přečemž jeho amplitudová rozlišovací schopnost dosahuje řádu 10e4. Vstupní signál je systémem FD-11 ŠOHAJ předzpracován a přenesen do aplikace Dcapture, kde dochází ke shromažďování dat v diskriminační matici. Shromažďovaná data jsou validována v rámci projektu vyvinutými filtračními a validačními metodami. Tuto matici je možné uložit a dále zpracovat v nástrojích pro dekonvoluci přístrojového spektra.Aplikace Dcapture slouží k průběžnému zachytávání a následnému zpracování dat z dvouparametrického spektrometrického systému FD-11 ŠOHAJ. Vstupní signál je systémem FD-11 ŠOHAJ předzpracován a přenesen do aplikace Dcapture, kde dochází ke shromažďování dat v diskriminační matici. Tuto matici je možné uložit a dále zpracovat v nástrojích pro dekonvoluci přístrojového spektra.Application DCapture is used to acquire and analysis data from two-parameter spectrometric system FD-11 SOHAJ. Two-parameter spectrometric system FD-11 SOHAJ came as a result of the project SPECTRUM TACR. It is protected by two utility models. Its data rate is two orders of magnitude faster than current spectrometeres, and its amplitude distinction reaches 10E4. Input signal is pre-processed in system FD-11 ŠOHAJ and then transferee to DCapture application and stored in discrimination matrix. The collected data are validated within a project developed filtering and validation methods. Application DCapture allows analyse and save this discrimination matrix for future processing
    corecore