110 research outputs found

    Serum tau protein as a marker for the diagnosis of Creutzfeldt-Jakob disease

    Get PDF
    Total tau protein (t-tau) levels in cerebrospinal fluid (CSF) (CSF-tau) are markedly elevated in patients with Creutzfeldt-Jakob disease (CJD). Some CSF-tau may leak into the blood. We evaluated t-tau levels in serum (serum-tau) as a possible marker for the differential diagnosis of CJD from Alzheimer\u27s disease (AD) and other rapidly progressive dementias (RPD). Serum- and CSF-tau levels were determined in patients with sporadic CJD (n = 12), AD (n = 10) and RPD but no CJD (non-CJD-RPD; n = 9) who showed RPD fulfilling the World Health Organization (WHO) criteria for possible CJD at onset and had a final diagnosis other than CJD. We also analyzed serum-tau levels in healthy volunteers as a control group (n = 10). Serum- as well as CSF-tau levels were significantly elevated in CJD group compared to those in AD, non-CJD-RPD and healthy control groups. Serum-tau would be a simple and useful marker to distinguish CJD from AD and non-CJD-RPD, requiring further large study to confirm this. © 2011 Springer-Verlag

    Acute Encephalitis Caused by Intrafamilial Transmission of Enterovirus 71 in Adult

    Get PDF
    Enterovirus 71 (EV71) is a common cause of hand, foot, and mouth disease and sometimes causes severe neurologic complications, mainly in children. We report a case of adult-onset encephalitis caused by intrafamilial transmission of a subgenogroup C4 strain of EV71. This case elucidates the risk for EV71 encephalitis even in adults

    Medical procedures and risk for sporadic creutzfeldt-jakob disease, Japan, 1999-2008

    Get PDF
    金沢大学医薬保健研究域医学系To elucidate the association between medical procedures and sporadic Creutzfeldt-Jakob disease (sCJD), we analyzed medical procedures (any surgical procedure, neu- rosurgery, ophthalmic surgery, and blood transfusion) for patients registered by the CJD Surveillance Committee in Japan during 1999-2008. We conducted an age-stratified case-control study with 753 sCJD patients and 210 controls and a study of patients who underwent neurosurgical or ophthalmic surgical procedures at the same hospital. Although the control group was relatively small, no evidence was found that prion disease was transmitted through the investigated medical procedures before onset of sCJD. After onset of sCJD, 4.5% of the sCJD patients underwent operations, including neurosurgical for 0.8% and ophthalmic for 1.9%; no special precautions against transmission of prion diseases were taken. Fortunately, we have not identified patients with prion disease attributed to these operations. Our findings indicate that surgical procedures or blood transfusion had little effect on the incidence of sCJD

    Ophthalmic Surgery in Prion Diseases

    Get PDF
    Eleven (1.8%) of 597 patients underwent ophthalmic surgery within 1 month before the onset of prion disease or after the onset. All ophthalmologists reused surgical instruments that had been incompletely sterilized to eliminate infectious prion protein. Ophthalmologists should be aware of prion diseases as a possible cause of visual symptoms and use disposable instruments whenever possible

    Reliability of DWI and FLAIR for diagnosis of sporadic CJD

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldte–Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Multicentre multiobserver study of diffusion-weighted and fluid-attenuated inversion recovery MRI for the diagnosis of sporadic Creutzfeldt–Jakob disease: a reliability and agreement study

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Design, Fabrication and Soundness Test of A Bi2223 Magnet Designed for Cooling by Liquid Hydrogen

    Get PDF
    The critical heat flux in liquid hydrogen is ten times higher than that in liquid helium and is approximately half of that in liquid nitrogen. Since the resistivity of pure metal such as copper or silver at 20 K is less than one-hundredth of that at 300 K, HTS magnets immersed in liquid hydrogen are expected to satisfy the fully cyostable condition or to be stable against high resistive heat generation enough for quench detection at a practical current density. In order to examine cryostability of HTS magnets in liquid hydrogen, a pool-cooled Bi2223 magnet with a 5 T magnetic field at 20 K has been designed, fabricated and tested in liquid nitrogen prior to excitation tests in liquid hydrogen. The magnet consists of six outer double pancake coils with the inner diameter of 0.20 m and four inner double pancake coils with the outer diameter of 0.16 m. The resistive voltage to initiate thermal runaway in the coil assembly in liquid nitrogen was higher than 1 V that is sufficient high for quench detection

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray
    corecore