377 research outputs found

    First axion dark matter search with toroidal geometry

    Get PDF
    We firstly report an axion haloscope search with toroidal geometry. In this pioneering search, we exclude the axion-photon coupling gaγγg_{a\gamma\gamma} down to about 5×1085\times10^{-8} GeV1^{-1} over the axion mass range from 24.7 to 29.1 μ\mueV at a 95\% confidence level. The prospects for axion dark matter searches with larger scale toroidal geometry are also considered.Comment: 5 pages, 5 figures, 1 table and to appear in PRD-R

    A new measurement of antineutrino oscillation with the full detector configuration at Daya Bay

    Full text link
    We report a new measurement of electron antineutrino disappearance using the fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data collected from October 2012 to November 2013 resulted in a total exposure of 6.9×\times105^5 GWth_{\rm th}-ton-days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six 241^{241}Am-13^{13}C radioactive calibration sources reduced the background by a factor of two for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of sin22θ13\sin^{2}2\theta_{13} and Δmee2|\Delta m^2_{ee}| were halved as a result of these improvements. Analysis of the relative antineutrino rates and energy spectra between detectors gave sin22θ13=0.084±0.005\sin^{2}2\theta_{13} = 0.084\pm0.005 and Δmee2=(2.42±0.11)×103|\Delta m^{2}_{ee}|= (2.42\pm0.11) \times 10^{-3} eV2^2 in the three-neutrino framework.Comment: Updated to match final published versio

    Observation of electron-antineutrino disappearance at Daya Bay

    Full text link
    The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle θ13\theta_{13} with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GWth_{\rm th} reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day livetime exposure in 55 days, 10416 (80376) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to expected number of antineutrinos at the far hall is R=0.940±0.011(stat)±0.004(syst)R=0.940\pm 0.011({\rm stat}) \pm 0.004({\rm syst}). A rate-only analysis finds sin22θ13=0.092±0.016(stat)±0.005(syst)\sin^22\theta_{13}=0.092\pm 0.016({\rm stat})\pm0.005({\rm syst}) in a three-neutrino framework.Comment: 5 figures. Version to appear in Phys. Rev. Let

    Impairments in hearing and vision impact on mortality in older people: the AGES-Reykjavik Study.

    Get PDF
    To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked Files. This article is open access.to examine the relationships between impairments in hearing and vision and mortality from all-causes and cardiovascular disease (CVD) among older people.population-based cohort study.the study population included 4,926 Icelandic individuals, aged ≥67 years, 43.4% male, who completed vision and hearing examinations between 2002 and 2006 in the Age, Gene/Environment Susceptibility-Reykjavik Study (AGES-RS) and were followed prospectively for mortality through 2009.participants were classified as having 'moderate or greater' degree of impairment for vision only (VI), hearing only (HI), and both vision and hearing (dual sensory impairment, DSI). Cox proportional hazard regression, with age as the time scale, was used to calculate hazard ratios (HR) associated with impairment and mortality due to all-causes and specifically CVD after a median follow-up of 5.3 years.the prevalence of HI, VI and DSI were 25.4, 9.2 and 7.0%, respectively. After adjusting for age, significantly (P < 0.01) increased mortality from all causes, and CVD was observed for HI and DSI, especially among men. After further adjustment for established mortality risk factors, people with HI remained at higher risk for CVD mortality [HR: 1.70 (1.27-2.27)], whereas people with DSI remained at higher risk of all-cause mortality [HR: 1.43 (1.11-1.85)] and CVD mortality [HR: 1.78 (1.18-2.69)]. Mortality rates were significantly higher in men with HI and DSI and were elevated, although not significantly, among women with HI.older men with HI or DSI had a greater risk of dying from any cause and particularly cardiovascular causes within a median 5-year follow-up. Women with hearing impairment had a non-significantly elevated risk. Vision impairment alone was not associated with increased mortality.National Institutes of Health, National Institute on Aging (NIA) N01-AG-12100 NIA Z01-AG007380 National Eye Institute (NEI) ZIAEY000401 National Institute on Deafness and Other Communication Disorders (NIDCD) Division of Scientific Programs/IAA Y2-DC-1004-02 Hjartavernd (Icelandic Heart Association) Althingi (Icelandic Parliament
    corecore