345 research outputs found

    A first-principles comparison of the electronic properties of MgC_{y}Ni_{3} and ZnC_{y}Ni_{3} alloys

    Full text link
    First-principles, density-functional-based electronic structure calculations are employed to study the changes in the electronic properties of ZnC_{y}Ni_{3} and MgC_{y}Ni_{3} using the Korringa-Kohn-Rostoker coherent-potential approximation method in the atomic sphere approximation (KKR-ASA CPA). As a function of decreasing C at%, we find a steady decrease in the lattice constant and bulk modulus in either alloys. However, the pressure derivative of the bulk modulus displays an opposite trend. Following the Debye model, which relates the pressure derivative of the bulk modulus with the average phonon frequency of the crystal, it can thus be argued that ZnCNi_{3} and its disordered alloys posses a different phonon spectra in comparison to its MgCNi_{3} counterparts. This is further justified by the marked similarity we find in the electronic structure properties such as the variation in the density of states and the Hopfield parameters calculated for these alloys. The effects on the equation of state parameters and the density of states at the Fermi energy, for partial replacement of Mg by Zn are also discussed.Comment: 19 pages, 15 figure

    Movies of cellular and sub-cellular motion by digital holographic microscopy

    Get PDF
    BACKGROUND: Many biological specimens, such as living cells and their intracellular components, often exhibit very little amplitude contrast, making it difficult for conventional bright field microscopes to distinguish them from their surroundings. To overcome this problem phase contrast techniques such as Zernike, Normarsky and dark-field microscopies have been developed to improve specimen visibility without chemically or physically altering them by the process of staining. These techniques have proven to be invaluable tools for studying living cells and furthering scientific understanding of fundamental cellular processes such as mitosis. However a drawback of these techniques is that direct quantitative phase imaging is not possible. Quantitative phase imaging is important because it enables determination of either the refractive index or optical thickness variations from the measured optical path length with sub-wavelength accuracy. Digital holography is an emergent phase contrast technique that offers an excellent approach in obtaining both qualitative and quantitative phase information from the hologram. A CCD camera is used to record a hologram onto a computer and numerical methods are subsequently applied to reconstruct the hologram to enable direct access to both phase and amplitude information. Another attractive feature of digital holography is the ability to focus on multiple focal planes from a single hologram, emulating the focusing control of a conventional microscope. METHODS: A modified Mach-Zender off-axis setup in transmission is used to record and reconstruct a number of holographic amplitude and phase images of cellular and sub-cellular features. RESULTS: Both cellular and sub-cellular features are imaged with sub-micron, diffraction-limited resolution. Movies of holographic amplitude and phase images of living microbes and cells are created from a series of holograms and reconstructed with numerically adjustable focus, so that the moving object can be accurately tracked with a reconstruction rate of 300ms for each hologram. The holographic movies show paramecium swimming among other microbes as well as displaying some of their intracellular processes. A time lapse movie is also shown for fibroblast cells in the process of migration. CONCLUSION: Digital holography and movies of digital holography are seen to be useful new tools for visualization of dynamic processes in biological microscopy. Phase imaging digital holography is a promising technique in terms of the lack of coherent noise and the precision with which the optical thickness of a sample can be profiled, which can lead to images with an axial resolution of a few nanometres

    International travel-related control measures to contain the COVID-19 pandemic: a rapid review

    Get PDF
    BACKGROUND: In late 2019, the first cases of coronavirus disease 2019 (COVID‐19) were reported in Wuhan, China, followed by a worldwide spread. Numerous countries have implemented control measures related to international travel, including border closures, travel restrictions, screening at borders, and quarantine of travellers. OBJECTIVES: To assess the effectiveness of international travel‐related control measures during the COVID‐19 pandemic on infectious disease transmission and screening‐related outcomes. SEARCH METHODS: We searched MEDLINE, Embase and COVID‐19‐specific databases, including the Cochrane COVID‐19 Study Register and the WHO Global Database on COVID‐19 Research to 13 November 2020. SELECTION CRITERIA: We considered experimental, quasi‐experimental, observational and modelling studies assessing the effects of travel‐related control measures affecting human travel across international borders during the COVID‐19 pandemic. In the original review, we also considered evidence on severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome (MERS). In this version we decided to focus on COVID‐19 evidence only. Primary outcome categories were (i) cases avoided, (ii) cases detected, and (iii) a shift in epidemic development. Secondary outcomes were other infectious disease transmission outcomes, healthcare utilisation, resource requirements and adverse effects if identified in studies assessing at least one primary outcome. DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles and abstracts and subsequently full texts. For studies included in the analysis, one review author extracted data and appraised the study. At least one additional review author checked for correctness of data. To assess the risk of bias and quality of included studies, we used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS‐2) tool for observational studies concerned with screening, and a bespoke tool for modelling studies. We synthesised findings narratively. One review author assessed the certainty of evidence with GRADE, and several review authors discussed these GRADE judgements. MAIN RESULTS: Overall, we included 62 unique studies in the analysis; 49 were modelling studies and 13 were observational studies. Studies covered a variety of settings and levels of community transmission. Most studies compared travel‐related control measures against a counterfactual scenario in which the measure was not implemented. However, some modelling studies described additional comparator scenarios, such as different levels of stringency of the measures (including relaxation of restrictions), or a combination of measures. Concerns with the quality of modelling studies related to potentially inappropriate assumptions about the structure and input parameters, and an inadequate assessment of model uncertainty. Concerns with risk of bias in observational studies related to the selection of travellers and the reference test, and unclear reporting of certain methodological aspects. Below we outline the results for each intervention category by illustrating the findings from selected outcomes. Travel restrictions reducing or stopping cross‐border travel (31 modelling studies) The studies assessed cases avoided and shift in epidemic development. We found very low‐certainty evidence for a reduction in COVID‐19 cases in the community (13 studies) and cases exported or imported (9 studies). Most studies reported positive effects, with effect sizes varying widely; only a few studies showed no effect. There was very low‐certainty evidence that cross‐border travel controls can slow the spread of COVID‐19. Most studies predicted positive effects, however, results from individual studies varied from a delay of less than one day to a delay of 85 days; very few studies predicted no effect of the measure. Screening at borders (13 modelling studies; 13 observational studies) Screening measures covered symptom/exposure‐based screening or test‐based screening (commonly specifying polymerase chain reaction (PCR) testing), or both, before departure or upon or within a few days of arrival. Studies assessed cases avoided, shift in epidemic development and cases detected. Studies generally predicted or observed some benefit from screening at borders, however these varied widely. For symptom/exposure‐based screening, one modelling study reported that global implementation of screening measures would reduce the number of cases exported per day from another country by 82% (95% confidence interval (CI) 72% to 95%) (moderate‐certainty evidence). Four modelling studies predicted delays in epidemic development, although there was wide variation in the results between the studies (very low‐certainty evidence). Four modelling studies predicted that the proportion of cases detected would range from 1% to 53% (very low‐certainty evidence). Nine observational studies observed the detected proportion to range from 0% to 100% (very low‐certainty evidence), although all but one study observed this proportion to be less than 54%. For test‐based screening, one modelling study provided very low‐certainty evidence for the number of cases avoided. It reported that testing travellers reduced imported or exported cases as well as secondary cases. Five observational studies observed that the proportion of cases detected varied from 58% to 90% (very low‐certainty evidence). Quarantine (12 modelling studies) The studies assessed cases avoided, shift in epidemic development and cases detected. All studies suggested some benefit of quarantine, however the magnitude of the effect ranged from small to large across the different outcomes (very low‐ to low‐certainty evidence). Three modelling studies predicted that the reduction in the number of cases in the community ranged from 450 to over 64,000 fewer cases (very low‐certainty evidence). The variation in effect was possibly related to the duration of quarantine and compliance. Quarantine and screening at borders (7 modelling studies; 4 observational studies) The studies assessed shift in epidemic development and cases detected. Most studies predicted positive effects for the combined measures with varying magnitudes (very low‐ to low‐certainty evidence). Four observational studies observed that the proportion of cases detected for quarantine and screening at borders ranged from 68% to 92% (low‐certainty evidence). The variation may depend on how the measures were combined, including the length of the quarantine period and days when the test was conducted in quarantine. AUTHORS' CONCLUSIONS: With much of the evidence derived from modelling studies, notably for travel restrictions reducing or stopping cross‐border travel and quarantine of travellers, there is a lack of 'real‐world' evidence. The certainty of the evidence for most travel‐related control measures and outcomes is very low and the true effects are likely to be substantially different from those reported here. Broadly, travel restrictions may limit the spread of disease across national borders. Symptom/exposure‐based screening measures at borders on their own are likely not effective; PCR testing at borders as a screening measure likely detects more cases than symptom/exposure‐based screening at borders, although if performed only upon arrival this will likely also miss a meaningful proportion of cases. Quarantine, based on a sufficiently long quarantine period and high compliance is likely to largely avoid further transmission from travellers. Combining quarantine with PCR testing at borders will likely improve effectiveness. Many studies suggest that effects depend on factors, such as levels of community transmission, travel volumes and duration, other public health measures in place, and the exact specification and timing of the measure. Future research should be better reported, employ a range of designs beyond modelling and assess potential benefits and harms of the travel‐related control measures from a societal perspective

    Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

    Get PDF
    AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m2^2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m2^2. Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.Comment: 40 pages, 33 figure

    Direct measurement of the muonic content of extensive air showers between 2×1017\mathbf { 2\times 10^{17}} and 2×1018 \mathbf {2\times 10^{18}}~eV at the Pierre Auger Observatory

    Get PDF
    The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between 2×1017^{17} and 2×1018^{18} eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at 1017.5^{17.5}eV and 1018^{18}eV. We find that, for the models to explain the data, an increase in the muon density of 38% ±4%(12%) ± (21%)¦(18%) for EPOS-LHC, and of 50%(53%) ±4%(13%) ± (23%)¦(20%) for QGSJetII-04, is respectively needed

    Status and performance of the underground muon detector of the Pierre Auger Observatory

    Get PDF
    The Auger Muons and Infill for the Ground Array (AMIGA) is an enhancement of the Pierre Auger Observatory, whose purpose is to lower the energy threshold of the observatory down to 1016.5 eV, and to measure the muonic content of air showers directly. These measurements will significantly contribute to the determination of primary particle masses in the range between the second knee and the ankle, to the study of hadronic interaction models with air showers, and, in turn, to the understanding of the muon puzzle. The underground muon detector of AMIGA is concomitant to two triangular grids of water-Cherenkov stations with spacings of 433 and 750 m; each grid position is equipped with a 30 m2 plastic scintillator buried at 2.3 m depth. After the engineering array completion in early 2018 and general improvements to the design, the production phase commenced. In this work, we report on the status of the underground muon detector, the progress of its deployment, and the performance achieved after two years of operation. The detector construction is foreseen to finish by mid-2022

    Performance of the 433 m surface array of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory, located in western Argentina, is the world’s largest cosmic-ray observatory. While it was originally built to study the cosmic-ray flux above 1018.5 eV, several enhancements have reduced this energy threshold. One such enhancement is a surface array composed of a triangular grid of 19 water-Cherenkov detectors separated by 433 m (SD-433) to explore the energies down to about 1016 eV. We are developing two research lines employing the SD-433. Firstly, we will measure the energy spectrum in a region where previous experiments have shown evidence of the second knee. Secondly, we will search for ultra-high energy photons to study PeV cosmic-ray sources residing in the Galactic center. In this work, we introduce the SD-433 and we show that it is fully efficient above 5×1016 eV for hadronic primaries with θ < 45°. Using seven years of data, we present the parametrization of the lateral distribution function of measured signals. Finally, we show that an angular resolution of 1.8° (0.5°) can be attained at the lowest (highest) primary energies. Our study lays the goundmark for measurements in the energy range above 1016 eV by utilizing the SD-433 and thus expanding the scientific output of the Auger surface detector

    Measurement of the cosmic-ray energy spectrum above 2.5 x 10(18) eV using the Pierre Auger Observatory

    Get PDF
    We report a measurement of the energy spectrum of cosmic rays for energies above 2.5×1018^{18} eV based on 215,030 events recorded with zenith angles below 60°. A key feature of the work is that the estimates of the energies are independent of assumptions about the unknown hadronic physics or of the primary mass composition. The measurement is the most precise made hitherto with the accumulated exposure being so large that the measurements of the flux are dominated by systematic uncertainties except at energies above 5×1019^{19} eV. The principal conclusions are (1) The flattening of the spectrum near 5×1018^{18} eV, the so-called “ankle,” is confirmed. (2) The steepening of the spectrum at around 5×10Z19^{Z19} eV is confirmed. (3) A new feature has been identified in the spectrum: in the region above the ankle the spectral index γ of the particle flux (∝Eγ^{−γ }) changes from 2.51±0.03 (stat)±0.05 (syst) to 3.05±0.05 (stat)±0.10 (syst) before changing sharply to 5.1±0.3 (stat)±0.1 (syst) above 5×1019^{19} eV. (4) No evidence for any dependence of the spectrum on declination has been found other than a mild excess from the Southern Hemisphere that is consistent with the anisotropy observed above 8×1018^{18} eV

    A combined fit of energy spectrum, shower depth distribution and arrival directions to constrain astrophysical models of UHECR sources

    Get PDF
    The combined fit of the measured energy spectrum and distribution of depths of shower maximum of ultra-high-energy cosmic rays is known to constrain the parameters of astrophysical scenarios with homogeneous source distributions. Further measurements show that the cosmic-ray arrival directions agree better with the directions and fluxes of catalogs of starburst galaxies and active galactic nuclei than with isotropy. Here, we present a novel combination of both analyses. For that, a three-dimensional universe model containing a nearby source population and a homogeneous background source distribution is built, and its parameters are adapted using a combined fit of the energy spectrum, depth of shower maximum distribution and energy-dependent arrival directions. The model takes into account a symmetric magnetic field blurring, source evolution and interactions during propagation. We use simulated data, which resemble measurements of the Pierre Auger Observatory, to evaluate the method’s sensitivity. With this, we are able to verify that the source parameters as well as the fraction of events from the nearby source population and the size of the magnetic field blurring are determined correctly, and that the data is described by the fitted model including the catalog sources with their respective fluxes and three-dimensional positions. We demonstrate that by combining all three measurements we reach the sensitivity necessary to discriminate between the catalogs of starburst galaxies and active galactic nuclei

    Features of the energy spectrum of cosmic rays above 2.5×1018 eV using the pierre auger observatory

    Get PDF
    We report a measurement of the energy spectrum of cosmic rays above 2.5×1018^{18} eV based on 215 030 events. New results are presented: at about 1.3×1019^{19} eV, the spectral index changes from 2.51±0.03(stat)±0.05(syst) to 3.05±0.05(stat)±0.10(syst), evolving to 5.1±0.3(stat)±0.1(syst) beyond 5×1019^{19} eV, while no significant dependence of spectral features on the declination is seen in the accessible range. These features of the spectrum can be reproduced in models with energy-dependent mass composition. The energy density in cosmic rays above 5×1018^{18} eV is [5.66±0.03(stat)±1.40(syst)]×1053^{53} erg Mpc3^{-3}
    corecore