251 research outputs found

    The relationship between human placental morphometry and ultrasonic measurements of utero-placental blood flow and fetal growth.

    Get PDF
    INTRODUCTION: Ultrasonic fetal biometry and arterial Doppler flow velocimetry are widely used to assess the risk of pregnancy complications. There is an extensive literature on the relationship between pregnancy outcomes and the size and shape of the placenta. However, ultrasonic fetal biometry and arterial Doppler flow velocimetry have not previously been studied in relation to postnatal placental morphometry in detail. METHODS: We conducted a prospective cohort study of nulliparous women in The Rosie Hospital, Cambridge (UK). We studied a group of 2120 women who had complete data on uterine and umbilical Doppler velocimetry and fetal biometry at 20, 28 and 36 weeks' gestational age, digital images of the placenta available, and delivered a liveborn infant at term. Associations were expressed as the difference in the standard deviation (SD) score of the gestational age adjusted ultrasound measurement (z-score) comparing the lowest and highest decile of the given placental morphometric measurement. RESULTS: The lowest decile of placental surface area was associated with 0.87 SD higher uterine artery Doppler mean pulsatility index (PI) at 20 weeks (95% CI: 0.68 to 1.07, P < 0.001). The lowest decile of placental weight was associated with 0.73 SD higher umbilical artery Doppler PI at 36 weeks (95% CI: 0.54 to 0.93, P < 0.001). The lowest decile of both placental weight and placental area were associated with reduced growth velocity of the fetal abdominal circumference between 20 and 36 weeks (both P < 0.001). CONCLUSION: Placental area and weight are associated with uterine and umbilical blood flow, respectively, and both are associated with fetal growth rate.This study was funded by the NIHR Cambridge Comprehensive Biomedical Research Centre (grant number A019057) and Stillbirth and Neonatal Death Society (SANDS). GE donated two ultrasound machines for use in the project.This is the author accepted manuscript. The final version is available from Elsevier via http://dx.doi.org/10.1016/j.placenta.2015.12.00

    Comparison of fully and semi-automated area-based methods for measuring mammographic density and predicting breast cancer risk.

    Get PDF
    BACKGROUND: Mammographic density is a strong risk factor for breast cancer but the lack of valid fully automated methods for quantifying it has precluded its use in clinical and screening settings. We compared the performance of a recently developed automated approach, based on the public domain ImageJ programme, to the well-established semi-automated Cumulus method. METHODS: We undertook a case-control study within the intervention arm of the Age Trial, in which ∼54,000 British women were offered annual mammography at ages 40-49 years. A total of 299 breast cancer cases diagnosed during follow-up and 422 matched (on screening centre, date of birth and dates of screenings) controls were included. Medio-lateral oblique (MLO) images taken closest to age 41 and at least one year before the index case's diagnosis were digitised for each participant. Cumulus readings were performed in the left MLO and ImageJ-based readings in both left and right MLOs. Conditional logistic regression was used to examine density-breast cancer associations. RESULTS: The association between density readings taken from one single MLO and breast cancer risk was weaker for the ImageJ-based method than for Cumulus (age-body mass index-adjusted odds ratio (OR) per one s.d. increase in percent density (95% CI): 1.52 (1.24-1.86) and 1.61 (1.33-1.94), respectively). The ImageJ-based density-cancer association strengthened when the mean of left-right MLO readings was used: OR=1.61 (1.31-1.98). CONCLUSIONS: The mean of left-right MLO readings yielded by the ImageJ-based method was as strong a predictor of risk as Cumulus readings from a single MLO image. The ImageJ-based method, using the mean of two measurements, is a valid automated alternative to Cumulus for measuring density in analogue films

    Body mass index trajectories from 2 to 18 years - exploring differences between European cohorts.

    Get PDF
    BACKGROUND: In recent decades, there has been an increase in the prevalence of childhood overweight in most high-income countries. Within northern Europe, prevalence tends to be higher in the UK compared with the Scandinavian countries. We aimed to study differences in body mass index (BMI) trajectories between large cohorts of children from UK and Scandinavian populations. METHODS: We compared BMI trajectories in participants from the English Avon Longitudinal Study of Parents and Children born in 1991-1993 (ALSPAC) (N = 6517), the Northern Finland Birth Cohorts born in 1966 (NFBC1966) (N = 3321) and 1986 (NFBC1986) (N = 4764), and the Danish Aarhus Birth Cohort born in 1990-1992 (ABC) (N = 1920). We used multilevel models to estimate BMI trajectories from 2 to 18 years. We explored whether cohort differences were explained by maternal BMI, height, education or smoking during pregnancy and whether differences were attributable to changes in the degree of skew in the BMI distribution. RESULTS: Differences in mean BMI between the cohorts were small but emerged early and persisted in most cases across childhood. Girls in ALSPAC had a higher BMI than all other cohorts throughout childhood, e.g. compared with the NFBC1986 BMI was 2.2-3.5% higher. For boys, the difference emerging over time (comparing the two NFBC's) exceeded the differences across populations (comparing NFBC1986, ABC and ALSPAC). BMI distribution demonstrated increasing right skew with age. CONCLUSION: Population-level differences between cohorts were small, tended to emerge very early, persisted across childhood, and demonstrated an increase in the right-hand tail of the BMI distribution

    Universal late pregnancy ultrasound screening to predict adverse outcomes in nulliparous women: a systematic review and cost-effectiveness analysis.

    Get PDF
    BACKGROUND: Currently, pregnant women are screened using ultrasound to perform gestational aging, typically at around 12 weeks' gestation, and around the middle of pregnancy. Ultrasound scans thereafter are performed for clinical indications only. OBJECTIVES: We sought to assess the case for offering universal late pregnancy ultrasound to all nulliparous women in the UK. The main questions addressed were the diagnostic effectiveness of universal late pregnancy ultrasound to predict adverse outcomes and the cost-effectiveness of either implementing universal ultrasound or conducting further research in this area. DESIGN: We performed diagnostic test accuracy reviews of five ultrasonic measurements in late pregnancy. We conducted cost-effectiveness and value-of-information analyses of screening for fetal presentation, screening for small for gestational age fetuses and screening for large for gestational age fetuses. Finally, we conducted a survey and a focus group to determine the willingness of women to participate in a future randomised controlled trial. DATA SOURCES: We searched MEDLINE, EMBASE and the Cochrane Library from inception to June 2019. REVIEW METHODS: The protocol for the review was designed a priori and registered. Eligible studies were identified using keywords, with no restrictions for language or location. The risk of bias in studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Health economic modelling employed a decision tree analysed via Monte Carlo simulation. Health outcomes were from the fetal perspective and presented as quality-adjusted life-years. Costs were from the perspective of the public sector, defined as NHS England, and the costs of special educational needs. All costs and quality-adjusted life-years were discounted by 3.5% per annum and the reference case time horizon was 20 years. RESULTS: Umbilical artery Doppler flow velocimetry, cerebroplacental ratio, severe oligohydramnios and borderline oligohydramnios were all either non-predictive or weakly predictive of the risk of neonatal morbidity (summary positive likelihood ratios between 1 and 2) and were all weakly predictive of the risk of delivering a small for gestational age infant (summary positive likelihood ratios between 2 and 4). Suspicion of fetal macrosomia is strongly predictive of the risk of delivering a large infant, but it is only weakly, albeit statistically significantly, predictive of the risk of shoulder dystocia. Very few studies blinded the result of the ultrasound scan and most studies were rated as being at a high risk of bias as a result of treatment paradox, ascertainment bias or iatrogenic harm. Health economic analysis indicated that universal ultrasound for fetal presentation only may be both clinically and economically justified on the basis of existing evidence. Universal ultrasound including fetal biometry was of borderline cost-effectiveness and was sensitive to assumptions. Value-of-information analysis indicated that the parameter that had the largest impact on decision uncertainty was the net difference in cost between an induced delivery and expectant management. LIMITATIONS: The primary literature on the diagnostic effectiveness of ultrasound in late pregnancy is weak. Value-of-information analysis may have underestimated the uncertainty in the literature as it was focused on the internal validity of parameters, which is quantified, whereas the greatest uncertainty may be in the external validity to the research question, which is unquantified. CONCLUSIONS: Universal screening for presentation at term may be justified on the basis of current knowledge. The current literature does not support universal ultrasonic screening for fetal growth disorders. FUTURE WORK: We describe proof-of-principle randomised controlled trials that could better inform the case for screening using ultrasound in late pregnancy. STUDY REGISTRATION: This study is registered as PROSPERO CRD42017064093. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 15. See the NIHR Journals Library website for further project information

    Risk factors associated with adverse perinatal outcome in planned vaginal breech labors at term : a retrospective population-based case-control study

    Get PDF
    Background: Vaginal breech delivery is associated with adverse perinatal outcome. The aim of this study was to identify factors associated with adverse perinatal outcome in term breech pregnancies, and to provide clinicians an aid in selecting women for a trial of vaginal labor with the fetus in breech position. Methods: We conducted a retrospective, nationwide, Finnish population-based case-control study. All planned singleton vaginal deliveries at term with the fetus in breech position between the years 2005 and 2014 were analyzed. The study's end point was a composite set of adverse perinatal outcomes. All infants with an adverse outcome were compared to the infants with normal outcomes. A multivariate logistic regression model was used to analyze the data. Results: An adverse perinatal outcome was recorded for 73 (1.5%) infants. According to the study results fetal growth restriction (adjusted odds ratio, 2.94; 95% CI, 1.30-6.67), oligohydramnios (adjusted odds ratio, 2.94; 95% CI, 1.15-7.18), a history of cesarean section (adjusted odds ratio, 2.94; 95% CI, 1.28-6.77, gestational diabetes (adjusted odds ratio, 2.89; 95% CI, 1.54-5.40), epidural anesthesia (adjusted odds ratio, 2.20; 95% CI, 1.29-3.75) and nulliparity (adjusted odds ratio, 1.84; 95% CI, 1.10-3.08) were associated with adverse perinatal outcome. Conclusions: Adverse perinatal outcome in planned vaginal breech labor at term is associated with fetal growth restriction, oligohydramnios, previous cesarean delivery, gestational diabetes, nulliparity and epidural anesthesia.Peer reviewe
    • …
    corecore