500 research outputs found

    Investigation of charge coupled device correlation techniques

    Get PDF
    Analog Charge Transfer Devices (CTD's) offer unique advantages to signal processing systems, which often have large development costs, making it desirable to define those devices which can be developed for general system's use. Such devices are best identified and developed early to give system's designers some interchangeable subsystem blocks, not requiring additional individual development for each new signal processing system. The objective of this work is to describe a discrete analog signal processing device with a reasonably broad system use and to implement its design, fabrication, and testing

    Performance and Fundamental Processes at Low Energy in a Two-Phase Liquid Xenon Dark Matter Detector

    Get PDF
    We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated sum of charge and light signals and introduce the corresponding discrimination parameter, giving its mean value at 4 kV/cm for electron and nuclear recoils up to 300 and 100 keV, respectively. We show that fluctuations in recombination limit discrimination for most energies, and reveal an improvement in discrimination below 20 keV due to a surprising increase in ionization yield for low energy electron recoils. This improvement is crucial for a high-sensitivity dark matter search.Comment: 4 pages, 6 figures, submitted to DM06 conference proceedings in Nucl Phys

    Scintillation Pulse Shape Discrimination in a Two-Phase Xenon Time Projection Chamber

    Full text link
    The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio simultaneously to obtain a leakage below that achievable by either discriminant alone. A Monte Carlo is used to show that the dominant fluctuation in the pulse shape quantity is statistical in nature, and project the performance of these techniques in larger detectors. Although the performance is generally weak at low energies relevant to elastic WIMP recoil searches, the pulse shape can be used in probing for higher energy inelastic WIMP recoils.Comment: 7 pages, 11 figure

    Exclusion limits on the WIMP-nucleon cross-section from the Cryogenic Dark Matter Search

    Get PDF
    The Cryogenic Dark Matter Search (CDMS) employs low-temperature Ge and Si detectors to search for Weakly Interacting Massive Particles (WIMPs) via their elastic-scattering interactions with nuclei while discriminating against interactions of background particles. For recoil energies above 10 keV, events due to background photons are rejected with >99.9% efficiency, and surface events are rejected with >95% efficiency. The estimate of the background due to neutrons is based primarily on the observation of multiple-scatter events that should all be neutrons. Data selection is determined primarily by examining calibration data and vetoed events. Resulting efficiencies should be accurate to about 10%. Results of CDMS data from 1998 and 1999 with a relaxed fiducial-volume cut (resulting in 15.8 kg-days exposure on Ge) are consistent with an earlier analysis with a more restrictive fiducial-volume cut. Twenty-three WIMP candidate events are observed, but these events are consistent with a background from neutrons in all ways tested. Resulting limits on the spin-independent WIMP-nucleon elastic-scattering cross-section exclude unexplored parameter space for WIMPs with masses between 10-70 GeV c^{-2}. These limits border, but do not exclude, parameter space allowed by supersymmetry models and accelerator constraints. Results are compatible with some regions reported as allowed at 3-sigma by the annual-modulation measurement of the DAMA collaboration. However, under the assumptions of standard WIMP interactions and a standard halo, the results are incompatible with the DAMA most likely value at >99.9% CL, and are incompatible with the model-independent annual-modulation signal of DAMA at 99.99% CL in the asymptotic limit.Comment: 40 pages, 49 figures (4 in color), submitted to Phys. Rev. D; v.2:clarified conclusions, added content and references based on referee's and readers' comments; v.3: clarified introductory sections, added figure based on referee's comment

    Model-Independent Comparison of Direct vs. Indirect Detection of Supersymmetric Dark Matter

    Get PDF
    We compare the rate for elastic scattering of neutralinos from various nuclei with the flux of upward muons induced by energetic neutrinos from neutralino annihilation in the Sun and Earth. We consider both scalar and axial-vector interactions of neutralinos with nuclei. We find that the event rate in a kg of germanium is roughly equivalent to that in a 10510^5- to 10710^7-m2^2 muon detector for a neutralino with primarily scalar coupling to nuclei. For an axially coupled neutralino, the event rate in a 50-gram hydrogen detector is roughly the same as that in a 10- to 500-m2^2 muon detector. Expected experimental backgrounds favor forthcoming elastic-scattering detectors for scalar couplings while the neutrino detectors have the advantage for axial-vector couplings.Comment: 10 pages, self-unpacking uuencoded PostScript fil

    Nuclear Shell Model Calculations of Neutralino-Nucleus Cross Sections for Silicon 29 and Germanium 73

    Full text link
    We present the results of detailed nuclear shell model calculations of the spin-dependent elastic cross section for neutralinos scattering from \si29 and \ge73. The calculations were performed in large model spaces which adequately describe the configuration mixing in these two nuclei. As tests of the computed nuclear wave functions, we have calculated several nuclear observables and compared them with the measured values and found good agreement. In the limit of zero momentum transfer, we find scattering matrix elements in agreement with previous estimates for \si29 but significantly different than previous work for \ge73. A modest quenching, in accord with shell model studies of other heavy nuclei, has been included to bring agreement between the measured and calculated values of the magnetic moment for \ge73. Even with this quenching, the calculated scattering rate is roughly a factor of 2 higher than the best previous estimates; without quenching, the rate is a factor of 4 higher. This implies a higher sensitivity for germanium dark matter detectors. We also investigate the role of finite momentum transfer upon the scattering response for both nuclei and find that this can significantly change the expected rates. We close with a brief discussion of the effects of some of the non-nuclear uncertainties upon the matrix elements.Comment: 31 pages, figures avaiable on request, UCRL-JC-11408

    Charge collection and electrode structures in ionization and phonon based dark matter detectors

    Get PDF
    We report on progress in our understanding of the physics of of implanted contacts, amorphous layer structures and Schottky contacts on detectors based on the simultaneous ionization and phonon based at 20 mK. Loss of charge for events near the contacts limits the capabilities of these detectors for detecting dark matter, an effect which is minimized by use of amorphous blocking layers

    Charge collection and electrode structures in ionization and phonon based dark matter detectors

    Get PDF
    We report on progress in our understanding of the physics of of implanted contacts, amorphous layer structures and Schottky contacts on detectors based on the simultaneous ionization and phonon based at 20 mK. Loss of charge for events near the contacts limits the capabilities of these detectors for detecting dark matter, an effect which is minimized by use of amorphous blocking layers

    3D Position Sensitive XeTPC for Dark Matter Search

    Get PDF
    The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.Comment: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark Matter and Dark Energy in the Universe
    • …
    corecore