13 research outputs found

    The Leukemia-Associated Fusion Protein MN1-TEL Blocks TEL-Specific Recognition Sequences

    Get PDF
    The leukemia-associated fusion protein MN1-TEL combines the transcription-activating domains of MN1 with the DNA-binding domain of the transcriptional repressor TEL. Quantitative photobleaching experiments revealed that ~20% of GFP-tagged MN1 and TEL is transiently immobilised, likely due to indirect or direct DNA binding, since transcription inhibition abolished immobilisation. Interestingly, ~50% of the MN1-TEL fusion protein was immobile with much longer binding times than unfused MN1 and TEL. MN1-TEL immobilisation was not observed when the TEL DNA-binding domain was disrupted, suggesting that MN1-TEL stably occupies TEL recognition sequences, preventing binding of factors required for proper transcription regulation, which may contribute to leukemogenesis

    Regels maken niet-farmacologisch onderzoek bij kinderen moeilijk

    No full text
    Many non-pharmacological interventions have only been tested in adults, and evidence on using these in children is lacking. To enhance child healthcare, research is required into these interventions in children. However, current rules and regulations make it difficult to conduct research into these low-risk, minimal-burden interventions. We describe the current rules and regulations on conducting research in children in the Netherlands and discuss the possibilities for adapting certain rules in accordance with the type of research that is performed

    Data from: Analytical performance, agreement and user-friendliness of six point of care testing urine analysers for urinary tract infection in general practice.

    No full text
    Objective: Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting: All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures: Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results: The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions: The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice

    Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    No full text
    OBJECTIVE: Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. SETTING: All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. PRIMARY AND SECONDARY OUTCOME MEASURES: Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. RESULTS: The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. CONCLUSIONS: The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice

    Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    No full text
    OBJECTIVE: Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. SETTING: All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. PRIMARY AND SECONDARY OUTCOME MEASURES: Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. RESULTS: The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. CONCLUSIONS: The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice

    Point-of-Care C-Reactive Protein Testing and Antibiotic Prescribing for Respiratory Tract Infections: A Randomized Controlled Trial

    No full text
    PURPOSE Antibiotics are only beneficial for subgroups of patients with acute lower respiratory tract infections (LRTI) and rhinosinusitis in family practice, yet overprescribing for these conditions is common. C-reactive protein (CRP) point-of-care testing and delayed prescribing are useful strategies to reduce antibiotic prescribing, but both have limitations. We evaluated the effect of CRP assistance in antibiotic prescribing strategies—including delayed prescribing—in the management of LRTI and rhinosinusitis

    Compilation of publication data

    No full text
    This Excel file contains all tables and the appendix present in the manuscript. There is no other data available

    MTT assay growth pattern of <i>M</i>. <i>tuberculosis</i> isolates at different INH concentration.

    No full text
    <p>(a) INH 0.1 μg/ml concentration: growth of isoniazid susceptible isolates RODU mean ± SE (n = 3, first week and n = 5, second and third weeks), and isoniazid resistant isolates (n = 4, first week and n = 5, second and third weeks). (b) INH 0.2 μg/ml concentration: growth of isoniazid susceptible isolates (n = 3, first week and n = 5, second and third weeks), and resistant isolates (n = 4, first week and n = 5, second and third weeks). (c) INH 0.4 μg/ml concentration: growth of isoniazid susceptible isolates (n = 3, first week and n = 5, second and third weeks), and isoniazid resistant isolates (n = 4, first week and n = 5 second and third weeks).</p

    Mutated zinc finger protein of the cerebellum 1 leads to microcephaly, cortical malformation, callosal agenesis, cerebellar dysplasia, tethered cord and scoliosis

    No full text
    Heterozygous gain of function mutations in the ZIC1 gene have been described with syndromic craniosynostosis, variable cerebral or cerebellar abnormalities and mild to moderate developmental delay. Deletion of chromosome 3q25.1 including both adjacent ZIC1 and ZIC4 genes have been described as a cause of variable cerebellar abnormalities including Dandy-Walker malformation. We report two siblings presenting with neonatal microcephaly, agenesis of the corpus callosum, brachycephaly with reduced volume of the posterior fossa, cerebellar and pons hypoplasia, scoliosis and tethered cord (closed neural tube defect). One of the siblings had apparent partial rhombencephalosynapsis. Trio analysis of exome sequencing data revealed a novel heterozygous frameshift mutation in ZIC1 at the end of exon 3 in one sibling and was confirmed by Sanger sequencing in both children. The mutation was not detected in DNA of both parents, which suggests parental gonadal mosaicism. We show that expression of the mutant allele leads to synthesis of a stable abnormal transcript in patient cells, without evidence for nonsense-mediated decay. Craniosynostosis was not present at birth, which explains why ZIC1 mutations were not initially considered. This severe brain malformation indicates that premature closure of sutures can be independent of the abnormal brain development in subjects with pathogenic variants in ZIC1

    Mutated zinc finger protein of the cerebellum 1 leads to microcephaly, cortical malformation, callosal agenesis, cerebellar dysplasia, tethered cord and scoliosis

    No full text
    Heterozygous gain of function mutations in the ZIC1 gene have been described with syndromic craniosynostosis, variable cerebral or cerebellar abnormalities and mild to moderate developmental delay. Deletion of chromosome 3q25.1 including both adjacent ZIC1 and ZIC4 genes have been described as a cause of variable cerebellar abnormalities including Dandy-Walker malformation. We report two siblings presenting with neonatal microcephaly, agenesis of the corpus callosum, brachycephaly with reduced volume of the posterior fossa, cerebellar and pons hypoplasia, scoliosis and tethered cord (closed neural tube defect). One of the siblings had apparent partial rhombencephalosynapsis. Trio analysis of exome sequencing data revealed a novel heterozygous frameshift mutation in ZIC1 at the end of exon 3 in one sibling and was confirmed by Sanger sequencing in both children. The mutation was not detected in DNA of both parents, which suggests parental gonadal mosaicism. We show that expression of the mutant allele leads to synthesis of a stable abnormal transcript in patient cells, without evidence for nonsense-mediated decay. Craniosynostosis was not present at birth, which explains why ZIC1 mutations were not initially considered. This severe brain malformation indicates that premature closure of sutures can be independent of the abnormal brain development in subjects with pathogenic variants in ZIC1
    corecore