30 research outputs found

    QbiasQ_{bias} -- A Dataset on Media Bias in Search Queries and Query Suggestions

    Full text link
    This publication describes the motivation and generation of QbiasQ_{bias}, a large dataset of Google and Bing search queries, a scraping tool and dataset for biased news articles, as well as language models for the investigation of bias in online search. Web search engines are a major factor and trusted source in information search, especially in the political domain. However, biased information can influence opinion formation and lead to biased opinions. To interact with search engines, users formulate search queries and interact with search query suggestions provided by the search engines. A lack of datasets on search queries inhibits research on the subject. We use QbiasQ_{bias} to evaluate different approaches to fine-tuning transformer-based language models with the goal of producing models capable of biasing text with left and right political stance. Additionally to this work we provided datasets and language models for biasing texts that allow further research on bias in online information search.Comment: Paper accepted at ACM Web Science Conference 2023. 6 page

    Text Simplification of Scientific Texts for Non-Expert Readers

    Full text link
    Reading levels are highly individual and can depend on a text's language, a person's cognitive abilities, or knowledge on a topic. Text simplification is the task of rephrasing a text to better cater to the abilities of a specific target reader group. Simplification of scientific abstracts helps non-experts to access the core information by bypassing formulations that require domain or expert knowledge. This is especially relevant for, e.g., cancer patients reading about novel treatment options. The SimpleText lab hosts the simplification of scientific abstracts for non-experts (Task 3) to advance this field. We contribute three runs employing out-of-the-box summarization models (two based on T5, one based on PEGASUS) and one run using ChatGPT with complex phrase identification.Comment: Paper accepted at SimpleText@CLEF'23, 12 pages, 1 Figure, 4 Table

    Sense-B-noise: an enigmatic cause for inappropriate shocks in subcutaneous implantable cardioverter defibrillators.

    Get PDF
    AIMS Subcutaneous implantable cardioverter defibrillators (S-ICDs) are well established. However, inappropriate shocks (IAS) remain a source of concern since S-ICDs offer very limited troubleshooting options. In our multicentre case series, we describe several patients who experienced IAS due to a previously unknown S-ICD system issue. METHODS AND RESULTS We observed six patients suffering from this novel IAS entity. The IAS occurred exclusively in primary or alternate S-ICD sensing vector configuration (therefore called 'Sense-B-noise'). IAS were caused by non-physiologic oversensing episodes characterized by intermittent signal saturation, diminished QRS amplitudes, and disappearance of the artefacts after the IAS. Noise/oversensing could not be provoked by manipulation, X-ray did not show evidence for lead/header issues and impedance measurements were within normal limits. The pooled experience of our centres implies that up to ∼5% of S-ICDs may be affected. The underlying root cause was discussed extensively with the manufacturer but remains unknown and is under further investigation. CONCLUSION Sense-B-noise is a novel cause for IAS due to non-physiologic signal oversensing, arising from a previously unknown S-ICD system issue. Sense-B-noise may be suspected if episodes of signal saturation in primary or alternate vector configuration are present, oversensing cannot be provoked, and X-ray and electrical measurements appear normal. The issue can be resolved by reprogramming the device to secondary sensing vector

    Sex-Related Differences in Patient Selection for and Outcomes after Pace and Ablate for Refractory Atrial Fibrillation: Insights from a Large Multicenter Cohort.

    Get PDF
    Background: A pace and ablate strategy may be performed in refractory atrial fibrillation with rapid ventricular response. Objective: We aimed to assess sex-related differences in patient selection and clinical outcomes after pace and ablate. Methods: In a retrospective multicentre study, patients undergoing AV junction ablation were studied. Sex-related differences in baseline characteristics, all-cause mortality, heart failure (HF) hospitalizations, and device-related complications were assessed. Results: Overall, 513 patients underwent AV junction ablation (median age 75 years, 50% men). At baseline, men were younger (72 vs. 78 years, p < 0.001), more frequently had non-paroxysmal AF (82% vs. 72%, p = 0.006), had a lower LVEF (35% vs. 55%, p < 0.001) and more frequently had cardiac resynchronization therapy (75% vs. 25%, p < 0.001). Interventional complications were rare in both groups (1.2% vs. 1.6%, p = 0.72). Patients were followed for a median of 42 months in survivors (IQR 22-62). After 4 years of follow-up, the combined endpoint of all-cause death or HF hospitalization occurred more often in men (38% vs. 27%, p = 0.008). The same was observed for HF hospitalizations (22% vs. 11%, p = 0.021) and all-cause death (28% vs. 21%, p = 0.017). Sex category remained an independent predictor of death or HF hospitalization after adjustment for age, LVEF and type of stimulation. Lead-related complications, infections, and upgrade to ICD or CRT occurred in 2.1%, 0.2% and 3.5% of patients, respectively. Conclusions: Pace and ablate is safe with a need for subsequent device-related re-interventions in 5.8% over 4 years. We found significant sex-related differences in patient selection, and women had a more favourable clinical course after AV junction ablation

    Transvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry.

    Get PDF
    BACKGROUND Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure

    Transvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry

    Get PDF
    BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure

    Epidemiology of soil-transmitted helminths following sustained implementation of routine preventive chemotherapy: Demographics and baseline results of a cluster randomised trial in southern Malawi.

    Get PDF
    Malawi has successfully leveraged multiple delivery platforms to scale-up and sustain the implementation of preventive chemotherapy (PCT) for the control of morbidity caused by soil-transmitted helminths (STH). Sentinel monitoring demonstrates this strategy has been successful in reducing STH infection in school-age children, although our understanding of the contemporary epidemiological profile of STH across the broader community remains limited. As part of a multi-site trial evaluating the feasibility of interrupting STH transmission across three countries, this study aimed to describe the baseline demographics and the prevalence, intensity and associated risk factors of STH infection in Mangochi district, southern Malawi. Between October-December 2017, a community census was conducted across the catchment area of seven primary healthcare facilities, enumerating 131,074 individuals across 124 villages. A cross-sectional parasitological survey was then conducted between March-May 2018 in the censused area as a baseline for a cluster randomised trial. An age-stratified random sample of 6,102 individuals were assessed for helminthiasis by Kato-Katz and completed a detailed risk-factor questionnaire. The age-cluster weighted prevalence of any STH infection was 7.8% (95% C.I. 7.0%-8.6%) comprised predominantly of hookworm species and of entirely low-intensity infections. The presence and intensity of infection was significantly higher in men and in adults. Infection was negatively associated with risk factors that included increasing levels of relative household wealth, higher education levels of any adult household member, current school attendance, or recent deworming. In this setting of relatively high coverage of sanitation facilities, there was no association between hookworm and reported access to sanitation, handwashing facilities, or water facilities. These results describe a setting that has reduced the prevalence of STH to a very low level, and confirms many previously recognised risk-factors for infection. Expanding the delivery of anthelmintics to groups where STH infection persist could enable Malawi to move past the objective of elimination of morbidity, and towards the elimination of STH. Trial registration: NCT03014167

    Sensitized Photocatalytic CO2 Reduction With Earth Abundant 3d Metal Complexes Possessing Dipicolyl-Triazacyclononane Derivatives

    Get PDF
    Complexes based on nitrogen and sulfur containing ligands involving 3d metal centers are known for the electrocatalytic reduction of CO2. However, photocatalytical activation has rarely been investigated. We herein present results on the light-driven CO2 reduction using either Ir(dFppy)3 [Ir, dFppy = 2-(4,6-difluorophenyl)pyridine] or [Cu(xant)(bcp)]+, (Cu, xant = xantphos, bcp = bathocuproine) as photosensitizer in combination with TEA (triethylamine) as sacrificial electron donor. The 3d metal catalysts have either dptacn (dipicolyl-triazacyclononane, LN3) or dpdatcn (dipicolyl-diazathiocyclononane, LN2S) as ligand framework and Fe3+, Co3+ or Ni2+ as central metal ion. It turned out that the choice of ligand, metal center and solvent composition influences the selectivity for product formation, which means that the gaseous reduction products can be solely CO or H2 or a mixture of both. The ratio between these two products can be controlled by the right choice of reaction conditions. With using Cu as photosensitizer, we could introduce an intermolecular system that is based solely on 3d metal compounds being able to reduce CO2.Peer Reviewe

    Calculating the prevalence of soil-transmitted helminth infection through pooling of stool samples: Choosing and optimizing the pooling strategy

    Get PDF
    Prevalence is a common epidemiological measure for assessing soil-transmitted helminth burden and forms the basis for much public-health decision-making. Standard diagnostic techniques are based on egg detection in stool samples through microscopy and these techniques are known to have poor sensitivity for individuals with low infection intensity, leading to poor sensitivity in low prevalence populations. PCR diagnostic techniques offer very high sensitivities even at low prevalence, but at a greater cost for each diagnostic test in terms of equipment needed and technician time and training. Pooling of samples can allow prevalence to be estimated while minimizing the number of tests performed. We develop a model of the relative cost of pooling to estimate prevalence, compared to the direct approach of testing all samples individually. Analysis shows how expected elative cost depends on both the underlying prevalence in the population and the size of the pools constructed. A critical prevalence level (approx. 31%) above which pooling is never cost effective, independent of pool size. When no prevalence information is available, there is no basis on which to choose between pooling and testing all samples individually. We recast our model of relative cost in a Bayesian framework in order to investigate how prior information about prevalence in a given population can be used to inform the decision to choose either pooling or full testing. Results suggest that if prevalence is below 10%, a relatively small exploratory prevalence survey (10–15 samples) can be sufficient to give a high degree of certainty that pooling may be relatively cost effective.© 2019 Truscott et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited

    Assessment of serum pharmacokinetics and urinary excretion of albendazole and its metabolites in human volunteers.

    Get PDF
    Soil Transmitted Helminth (STH) infections negatively impact physical and mental development in human populations. Current WHO guidelines recommend morbidity control of these infections through mass drug administration (MDA) using albendazole (ABZ) or mebendazole. Despite major reductions in STH associated morbidity globally, not all programs have demonstrated the expected impact on prevalence of parasite infections. These therapeutic failures may be related to poor programmatic coverage, suboptimal adherence or the exposure of parasites to sub-therapeutic drug concentrations. As part of the DeWorm3 project, we sought to characterize the serum disposition kinetics and pattern of urinary excretion of ABZ and its main metabolites ABZ sulphoxide (ABZSO) and ABZ sulphone (ABZSO2) in humans, and the assessment of the duration and optimal time point where ABZ and/or its metabolites can be measured in urine as an indirect assessment of an individual's adherence to treatment.Consecutive venous blood and urine samples were collected from eight (8) human volunteers up to 72 h post-ABZ oral administration. ABZ/metabolites were quantified by HPLC. The ABZSO metabolite was the main analyte recovered both in serum and urine. ABZSO Cmax in serum was 1.20 ± 0.44 μg/mL, reached at 4.75 h post-treatment. In urine, ABZSO Cmax was 3.24 ± 1.51 μg/mL reached at 6.50 h post-ABZ administration.Pharmacokinetic data obtained for ABZ metabolites in serum and urine, including the recovery of the ABZ sulphoxide derivative up to 72 h in both matrixes and the recovery of the amino-ABZ sulphone metabolite in urine samples, are suggesting the possibility of developing a urine based method to assess compliance to ABZ treatment. Such an assay may be useful to optimize ABZ use in human patients.ClinicalTrials.gov NCT03192449
    corecore